电工技术学报  2019, Vol. 34 Issue (zk2): 501-508    DOI: 10.19595/j.cnki.1000-6753.tces.180887
电机与电器 |
GW4隔离开关机械故障仿真与诊断技术
马宏明1, 周涛涛2, 彭诗怡2, 邱志斌2, 朱琳3
1. 云南电网有限责任公司电力科学研究院 昆明 650217;
2. 武汉大学电气与自动化学院 武汉 430072;
3. 国网湖北省电力公司技术培训中心 武汉 430079
Research on Mechanical Fault Simulation and Diagnosis Technology of GW4 Disconnector
Ma Hongming1, Zhou Taotao2, Peng Shiyi2, Qiu Zhibin2, Zhu Lin3
1. Electric Power Research Institute Yunnan Power Grid Co. Ltd Kunming 650217 China;
2. School of Electrical Engineering and Automation Wuhan University Wuhan 430072 China;
3. Technology Training Center State Grid Hubei Electric Power Company Wuhan 430079 China
全文: PDF (36825 KB)  
输出: BibTeX | EndNote (RIS)      
摘要 隔离开关是电力系统用量最多的高压开关设备之一,因安装调试不当或长时间运行后由于大气腐蚀、传动机构关节润滑脂流失、异物与灰尘积累等,导致隔离开关容易出现操作卡涩。针对隔离开关这类故障隐患的影响与诊断,目前研究较少,尚无有效检测诊断方法。本文以某GW4A-126型隔离开关为研究对象,通过建立虚拟样机模型,对比分析计算隔离开关处于正常状态、卡涩、三相不同期三种状态时的合闸力矩波形,由此提出一种基于操作力矩与操作杆转角检测的隔离开关机械故障诊断方法,并通过试验验证了该方法的可行性,在此基础上总结出基于操作力矩-转角曲线的隔离开关机械故障诊断流程,为隔离开关的安装调试、检修维护提供参考。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
马宏明
周涛涛
彭诗怡
邱志斌
朱琳
关键词 隔离开关机械故障故障仿真故障诊断操作力矩    
Abstract:Disconnectors are the mostly used high-voltage switchgear in power systems. Due to improper installation and debugging, loss of joint grease in the transmission mechanism, accumulation of foreign matter and dust, etc., the disconnector is prone to jammed faults. At present, there are few studies on the diagnosis of hidden mechanical faults of disconnectors, and there is no effective detection method. In this paper, a GW4A-126 disconnector is taken as the research object. The virtual prototype model is established, and the operating torque waveforms are calculated and analyzed in the condition of normal state, jammed state, three-phase position asynchrony. Thus, a mechanical fault diagnosis method for disconnector based on operating torque and the operating shaft rotation angle is proposed, and the feasibility of the method is verified by experiments. Based on this, a mechanical fault diagnosis process of disconnector based on operating torque-angle curve is summarized, which could provide reference for the installation, debugging and maintenance of disconnector.
Key wordsDisconnector    mechanical failure    fault simulation    fault diagnosis    operating torque   
收稿日期: 2018-05-26      出版日期: 2020-01-02
PACS: TM564.1  
作者简介: 马宏明 男,1987年生,工程师,硕士,研究方向为高压开关设备状态评价。E-mail: ncepuming@126.com
引用本文:   
马宏明, 周涛涛, 彭诗怡, 邱志斌, 朱琳. GW4隔离开关机械故障仿真与诊断技术[J]. 电工技术学报, 2019, 34(zk2): 501-508. Ma Hongming, Zhou Taotao, Peng Shiyi, Qiu Zhibin, Zhu Lin. Research on Mechanical Fault Simulation and Diagnosis Technology of GW4 Disconnector. Transactions of China Electrotechnical Society, 2019, 34(zk2): 501-508.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/10.19595/j.cnki.1000-6753.tces.180887          https://dgjsxb.ces-transaction.com/CN/Y2019/V34/Izk2/501