Diagnosis of Inter-Turn Short-Circuit Fault for Five-Phase Permanent Magnet Machine Based on Fault-Tolerant Tooth Flux
Huang Jian1, Yin Zuosheng1, Wang Tianyi1, Song Zhiyi1, Sui Yi2
1. Beijing Institute of Automatic Control Equipment Beijing 100074 China; 2. School of Electrical Engineering and Automation Harbin Institute of Technology Harbin 150001 China
Abstract:Inter-turn short-circuit fault is a common machine winding fault with great harm and easy- diffusion characteristics. The fast inter-turn short-circuit fault diagnosis is necessary to avoid further fatal failure, which is a research focus for the multi-phase fault-tolerant permanent magnet synchronous machine (PMSM). The existing short-circuit fault diagnosis methods based on high-frequency signal injection, current harmonic component extraction, zero-sequence voltage monitoring, and detection coil are mostly bound with fast Fourier transform (FFT). The dependence on FFT brings problems of increased computation, longer diagnosis time, and sensitivity to operating conditions. It is hard to achieve the balance of diagnosis speed, accuracy, and simplicity. Therefore, an inter-turn short-circuit fault diagnosis method based on fault-tolerant tooth flux is proposed for a five-phase PMSM. The proposed method is independent of FFT, load, and machine speed, which has the advantages of high accuracy, fast speed, simple process, and robustness. Firstly, the stator magnetic circuit model of the five-phase PMSM is established, and the influence of inter-turn short-circuit fault on the flux of winding and fault-tolerant teeth is given. Secondly, variations of the induced electromotive force (EMF) of different arranged detection coils with the operating state of the machine are investigated. The fault identification ability, sensitivity and complexity of each winding scheme are comprehensively evaluated. Thirdly, the fault identification and locating method by fault sign αi is presented for the fault diagnosis based on the fault-tolerant tooth flux. Finally, the influence law of slot-opening width and fault-tolerant tooth length on fault sensitivity and machine performances is further analyzed, and the size selection method is given. There is flux in the fault-tolerant teeth between in-phase coils only when the inter-turn short-circuit fault occurs in the phase. Compared with other arranging schemes, the fault detection coils arranged on the fault-tolerant tooth can distinguish the normal condition, open-circuit fault, and short-circuit fault explicitly, which is adopted for fault diagnosis. The decreased induced EMF amplitude in a specific detection coil indicates an inter-turn short-circuit fault. The fault sign αi is introduced as the ratio of detection coil-induced EMF amplitude to the reference value to characterize the decreasing detection coil induced EMF in the fault phase. When the inter-turn short-circuit fault occurs to the machine, αi value of the fault phase is significantly reduced, αi values of the remaining healthy phases are close to 1. According to this feature, faults can be accurately identified and located. With the increase of slot-opening width b01, the sensitivities to small and large turn short-circuit faults are lower and higher, respectively. The fault diagnosis is more complex with the decrease of fault-tolerant tooth length Lt. With additional consideration of machine performances, values of b01 and Lt are chosen as 1.5 mm and 19.5 mm, respectively. The following conclusions can be drawn from the analytical and simulation analysis: (1) The flux in the fault-tolerant teeth between in-phase coils appears only when the inter-turn short-circuit fault occurs, which is a key characteristic for fault diagnosis. (2) An inter-turn short-circuit fault diagnosis method based on fault-tolerant tooth flux is proposed, with independent detection coils in each fault-tolerant tooth. (3) When the inter-turn short-circuit fault occurs, the fault sign αi value of the fault phase is significantly reduced, and αi values of the remaining healthy phases are close to 1, which can indicate fault appearance and fault position. (4) The proposed method is independent of FFT, load, and machine speed, with the advantages of high accuracy, fast speed, simple process, and robustness. (5) To balance the sensitivities of small and large turn short-circuit fault diagnosis and machine performances, slot-opening width b01 should not be too large or too small, and a short tooth design is not recommended.
黄建, 尹佐生, 王天乙, 宋志翌, 隋义. 基于容错齿磁通的五相永磁电机匝间短路故障诊断[J]. 电工技术学报, 2023, 38(14): 3733-3744.
Huang Jian, Yin Zuosheng, Wang Tianyi, Song Zhiyi, Sui Yi. Diagnosis of Inter-Turn Short-Circuit Fault for Five-Phase Permanent Magnet Machine Based on Fault-Tolerant Tooth Flux. Transactions of China Electrotechnical Society, 2023, 38(14): 3733-3744.
[1] 陶涛, 赵文祥, 程明, 等. 多相电机容错控制及其关键技术综述[J]. 中国电机工程学报, 2019, 39(2): 316-326, 629. Tao Tao, Zhao Wenxiang, Cheng Ming, et al.Review on fault-tolerant control of multi-phase machines and their key technologies[J]. Proceedings of the CSEE, 2019, 39(2): 316-326, 629. [2] Zhao Wenxiang, Xu Liang, Liu Guohai.Overview of permanent-magnet fault-tolerant machines: topology and design[J]. CES Transactions on Electrical Machines and Systems, 2018, 2(1): 51-64. [3] 李修东, 郑晓钦, 王海峰, 等. 最大转矩范围内九相永磁同步电机缺相容错运行铜耗优化策略[J]. 电工技术学报, 2022, 37(17): 4355-4363. Li Xiudong, Zheng Xiaoqin, Wang Haifeng, et al.Copper loss optimization strategy for nine-phase permanent magnet synchronous motors fault-tolerant operation in maximum torque range[J]. Transactions of China Electrotechnical Society, 2022, 37(17): 4355-4363. [4] 陈前, 夏雨航, 赵文祥, 等. 采用无差拍电流跟踪的五相梯形反电动势永磁电机开路容错控制[J]. 电工技术学报, 2022, 37(2): 368-379. Chen Qian, Xia Yuhang, Zhao Wenxiang, et al.Open- circuit fault-tolerant control for five-phase permanent magnet motors with trapezoidal back-EMF by deadbeat current tracking[J]. Transactions of China Electrotechnical Society, 2022, 37(2): 368-379. [5] 隋义. 纯电动汽车用五相容错永磁同步电机的关键技术研究[D]. 哈尔滨: 哈尔滨工业大学, 2015. [6] 尹佐生. 航天伺服用四相容错永磁电机研究[D]. 哈尔滨: 哈尔滨工业大学, 2018. [7] 张业成, 刘国海, 陈前. 基于电流波动特征的永磁同步电机匝间短路与局部退磁故障分类诊断研究[J]. 电工技术学报, 2022, 37(7): 1634-1643, 1653. Zhang Yecheng, Liu Guohai, Chen Qian.Discrimi- nation of interturn short-circuit and local demag- netization in permanent magnet synchronous motor based on current fluctuation characteristics[J]. Transactions of China Electrotechnical Society, 2022, 37(7): 1634-1643, 1653. [8] Hang Jun, Zhang Jianzhong, Cheng Ming, et al.Detection and discrimination of open-phase fault in permanent magnet synchronous motor drive system[J]. IEEE Transactions on Power Electronics, 2016, 31(7): 4697-4709. [9] Estima J O, Marques Cardoso A J. A new algorithm for real-time multiple open-circuit fault diagnosis in voltage-fed PWM motor drives by the reference current errors[J]. IEEE Transactions on Industrial Electronics, 2013, 60(8): 3496-3505. [10] 张潇丹, 段斌, 刘昌杰, 等. 基于本体追踪的永磁同步电机驱动系统开路故障诊断方法[J]. 电工技术学报, 2022, 37(13): 3341-3349, 3360. Zhang Xiaodan, Duan Bin, Liu Changjie, et al.Open circuit fault diagnosis method for permanent magnet synchronous machine drive system based on ontology tracking[J]. Transactions of China Electrotechnical Society, 2022, 37(13): 3341-3349, 3360. [11] Duran M J, Gonzalez-Prieto I, Rios-Garcia N, et al.A simple, fast, and robust open-phase fault detection technique for six-phase induction motor drives[J]. IEEE Transactions on Power Electronics, 2018, 33(1): 547-557. [12] 谢颖, 胡圣明, 陈鹏, 等. 永磁同步电机匝间短路故障温度场分析[J]. 电工技术学报, 2022, 37(2): 322-331. Xie Ying, Hu Shengming, Chen Peng, et al.Thermal field analysis on inter-turn short circuit fault of permanent magnet synchronous motor[J]. Transa- ctions of China Electrotechnical Society, 2022, 37(2): 322-331. [13] 杜博超. 电动汽车永磁同步电机驱动系统故障诊断与容错技术研究[D]. 哈尔滨: 哈尔滨工业大学, 2016. [14] Briz F, Degner M W, Zamarron A, et al.Online stator winding fault diagnosis in inverter-fed AC machines using high-frequency signal injection[J]. IEEE Transa- ctions on Industry Applications, 2003, 39(4): 1109-1117. [15] Hu Rongguang, Wang Jiabin, Mills A R, et al.High-frequency voltage injection based stator inter- turn fault detection in permanent magnet machines[J]. IEEE Transactions on Power Electronics, 2021, 36(1): 785-794. [16] Ebrahimi B M, Faiz J.Feature extraction for short- circuit fault detection in permanent-magnet syn- chronous motors using stator-current monitoring[J]. IEEE Transactions on Power Electronics, 2010, 25(10): 2673-2682. [17] Kim K H.Simple online fault detecting scheme for short-circuited turn in a PMSM through current harmonic monitoring[J]. IEEE Transactions on Industrial Electronics, 2011, 58(6): 2565-2568. [18] Urresty J C, Riba J R, Romeral L.Diagnosis of inter- turn faults in PMSMs operating under nonstationary conditions by applying order tracking filtering[J]. IEEE Transactions on Power Electronics, 2013, 28(1): 507-515. [19] Hang Jun, Zhang Jianzhong, Cheng Ming, et al.Online interturn fault diagnosis of permanent magnet synchronous machine using zero-sequence com- ponents[J]. IEEE Transactions on Power Electronics, 2015, 30(12): 6731-6741. [20] 孙宇光, 杜威, 桂林, 等. 用于多相无刷励磁机开路与短路故障检测的磁极探测线圈设计[J]. 电工技术学报, 2022, 37(14): 3542-3554. Sun Yuguang, Du Wei, Gui Lin, et al.Design of pole detection coils for open-circuit and short-circuit faults in multiphase brushless exciter[J]. Transactions of China Electrotechnical Society, 2022, 37(14): 3542-3554. [21] Chai Jie, Wang Jiabin, Atallah K, et al.Performance comparison and winding fault detection of duplex 2-phase and 3-phase fault-tolerant permanent magnet brushless machines[C]//2007 IEEE Industry Appli- cations Annual Meeting, New Orleans, LA, USA, 2007: 566-572. [22] Kim K T, Lee S T, Hur J.Diagnosis technique using a detection coil in BLDC motors with interturn faults[J]. IEEE Transactions on Magnetics, 2014, 50(2): 885-888. [23] Lee S T, Kim K T, Hur J.Diagnosis technique for stator winding inter-turn fault in BLDC motor using detection coil[C]//2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia), Seoul, Korea (South), 2015: 2925-2931. [24] 曾冲. 基于定子齿磁通的永磁同步电机故障诊断研究[D]. 重庆: 重庆大学, 2019.