1. School of Automation Engineering University of Electronic Science and Technology of China Chengdu 611731 China; 2. Institute of Electric Vehicle Driving System and Safety Technology University of Electronic Science and Technology of China Chengdu 611731 China
Abstract:An on-line diagnosis of power transistor in inverter circuit based on current observer is proposed in this paper, aiming at improving maintenance efficiency and enhancing reliability levels. Firstly, a current observer for three-phase inverter circuit is established through building its state space model and analyzing its additional function. Secondly, according to the error between the measured and observed value of the three-phase current, the periodic mean value of the error is used to avoid the interference caused by the noise as much as possible. After the coordinate transformation of the periodic mean value of the error, the fault vector angle is obtained. Combined with the fault parameter obtained by the normalized value of the sum of the absolute values of the measured currents, on-line open-fault diagnosis and location for power transistor is realized. Finally, Matlab/simulink software and dSPACE platforms are used for the simulation and experimental verification.
[1] Yang Shaoyong, Xiang Dawei, Bryant A, et al.Condition monitoring for device reliability in power electronic converters: a review[J]. IEEE Transactions on Power Electronics, 2010, 25(11): 2734-2752. [2] Zhang Wenping, Xu Dehong, Enjeti P N, et al.Survey on fault-tolerant techniques for power electronic converters[J]. IEEE Transactions on Power Electronics, 2014, 29(12): 6319-6331. [3] 安群涛, 孙力, 孙立志, 等. 三相逆变电路开关管故障诊断方法研究进展[J]. 电工技术学报, 2011, 26(4): 135-144. An Quntao, Sun Li, Sun Lizhi, et al.Recent deve- lopments of fault diagnosis methods for switches in three-phase inverters[J]. Transactions of China Electrotechnical Society, 2011, 26(4): 135-144. [4] 成庶, 李蔚, 陈特放, 等. 整流器主电路开路故障诊断及容错控制研究[J]. 电工技术学报, 2016, 31(13): 26-35. Cheng Shu, Li Wei, Chen Tefang, et al.Research on open-circuit fault diagnosis and fault-tolerant control[J]. Transactions of China Electrotechnical Society, 2016, 31(13): 26-35. [5] Rothenhagen K, Fuchs F W.Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers[C]//IEEE Power Elec- tronics Specialists Conference, Aachen, Germany, 2004, 6: 4348-4354. [6] Brunson C, Empringham L, Lillo L D, et al.Open- circuit fault detection and diagnosis in matrix converters[J]. IEEE Transactions on Power Electro- nics, 2014, 30(5): 2840-2847. [7] Jlassi I, Estima J O, Khil S K E, et al. Multiple open- circuit faults diagnosis in back-to-back converters of PMSG drives for wind turbine systems[J]. IEEE Transa- ctions on Power Electronics, 2015, 30(5): 2689-2702. [8] 谢东, 葛兴来. 基于残差变化率的单相级联H桥整流器IGBT开路故障诊断[J]. 电工技术学报, 2018, 33(16): 166-178. Xie Dong, Ge Xinglai.Residual-changing-rate based open-circuit fault diagnosis for a single-phase cascaded H-bridge rectifier[J]. Transactions of China Electrotechnical Society, 2018, 33(16): 166-178. [9] 马皓, 林钊, 王小瑞. 不平衡非线性负载下三相逆变器的建模与控制[J]. 电工技术学报, 2015, 30(18): 83-95. Ma Hao, Lin Zhao, Wang Xiaorui.Modeling and control of three-phase inverter powering unbalanced and nonlinear loads[J]. Transactions of China Electrotechnical Society, 2015, 30(18): 83-95. [10] Campos-Delgado D U, Espinoza-Trejo D R. An observer-based diagnosis scheme for single and simultaneous open-switch faults in induction motor drives[J]. IEEE Transactions on Industrial Electro- nics, 2011, 58(2): 671-679. [11] Jlassi I, Estima J O, Khil S K E, et al. Multiple open-circuit faults diagnosis in back-to-back con- verters of PMSG drives for wind turbine systems[J]. IEEE Transactions on Power Electronics, 2015, 30(5): 2689-2702. [12] Jlassi I, Estima J O, Khil S K E, et al. A robust observer-based method for IGBTs and current sensors fault diagnosis in voltage-source inverters of PMSM drives[J]. IEEE Transactions on Industry Appli- cations, 2017, 53(3): 2894-2905. [13] An Quntao, Sun Li, Sun Lizhi.Current residual vector- based open-switch fault diagnosis of inverters in PMSM drive systems[J]. IEEE Transactions on Power Electronics, 2015, 30(5): 2814-2827. [14] 李宁, 李颖晖, 朱喜华, 等. 混杂系统理论及其在三相逆变电路开路故障诊断中的应用[J]. 电工技术学报, 2014, 29(6): 114-119. Li Ning, Li Yinghui, Zhu Xihua, et al.Fault diagnosis for power electronic circuits based on mixed logic dynamic model and incident identi- fication vector[J]. Transactions of China Electro- technical Society, 2014, 29(6): 114-119. [15] Ding Xiangyu, Poon J, Čelanović I, et al.Fault detection and isolation filters for three-phase AC-DC power electronics systems[J]. IEEE Transactions on Circuits & Systems I: Regular Papers, 2013, 60(4): 1038-1051. [16] Errabelli R R, Mutschler P.Fault-tolerant voltage source inverter for permanent magnet drives[J]. IEEE Transactions on Power Electronics, 2012, 27(2): 500-508. [17] 闫朝阳, 白鹤, 张喆, 等. 不平衡工况下基于虚拟阻抗法的并联三相四桥臂逆变器的桥臂控制[J]. 电工技术学报, 2017, 32(23): 207-219. Yan Zhaoyang, Bai He, Zhang Zhe, et al.Leg control of parallel three-phase four-leg inverter based on virtual impedance method under unbalanced conditions[J]. Transactions of China Electrotechnical Society 2017, 32(23): 207-219. [18] Cecati C, Tommaso A O D, Genduso F, et al. Comprehensive modeling and experimental testing of fault detection and management of a nonredundant fault-tolerant VSI[J]. IEEE Transactions on Industrial Electronics, 2015, 62(6): 3945-3954. [19] 张铭, 郭源博, 李泽, 等. 容错控制模式下三电平逆变器输出电压不平衡抑制方法[J]. 电工技术学报, 2018, 33(22): 5300-5310. Zhang Ming, Guo Yuanbo, Li Ze, et al.Suppression algorithm for output voltage unbalance of three-level inverters under fault tolerant operation[J]. Transa- ctions of China Electrotechnical Society, 2018, 33(22): 5300-5310.