Abstract:For a dual-active-bridge(DAB) dc-dc converter with the traditional single-phase-shift (SPS) control, there are power circulating flow and larger current stress when the voltage conversion ratio is not equal to one. In order to eliminate the power circulating flow and reduce the current stress, dual-phase-shift(DPS) control is proposed and gained more attractive. All possible modes of DPS control is first analyzed in this paper, and the operating principle of DPS control is then analyzed. The transmission power and current stress of DAB dc-dc converter with both SPS and DPS control were analyzed and derived respectively. On this basis, the constraint condition to minimize the current stress, as well as optimal current control and implement scheme with all modes of DPS control, are analyzed and derived later, therefore minimal current stress and higher efficiency are ensured in a DAB dc-dc converter. The experimental results verify the correctness and excellent performance of the proposed optimal current control strategy.
王玉斌,王杉杉,封波,董彦彦. 基于双重移相控制的双有源DC-DC变换器的最优电流控制[J]. 电工技术学报, 2015, 30(14): 488-496.
Wang Yubin,Wang Shanshan,Fengbo,Dong Yanyan. Optimal Current Control Strategy of Dual-Active-Bridge DC-DC Converter Based on Dual-Phase-Shift Control. Transactions of China Electrotechnical Society, 2015, 30(14): 488-496.
[1] NGO T, LEE K, et al. Study of single-phase bidirectional battery charger for high power application[C]. IPEMC, Harbin, 2012: 958-962. [2] NAAYAGI R T, FORSYTH A J. Bidirectional DC-DC converter for aircraft electric energy storage systems[C]. PEMD, Brighton, UK, 2010: 1-6. [3] DE DONCKER R A, DIVAN D M, et al. A three-phase soft-switched high-power-density DC/DC converter for high- power applications[J]. IEEE Trans. on Industry Applications, 1991, 27(1): 63-73. [4] MI C, BAI H, WANG C, et al. Operation, design and control of dual H-bridge-based isolated bidirectional DC-DC converter [J]. Power Electronics, IET, 2008, 1(4): 507-517. [5] XIE Yan-hui, SUN J, et al. Power flow characterization of a bidirectional isolated high-power DC/DC converter over a wide operating range[J]. IEEE Trans. on Power Electronics, 2010, 25(1): 54-66. [6] I.Shigenori, A. Hirofumi. A bidirectional isolated DC-DC converter as a core circuit of the next- generation medium-voltage power conversion system [J]. IEEE Trans. on Power Electronics, 2007, 22(2): 535-542. [7] I.Shigenori, A. Hirofumi. A bidirectional isolated DC-DC converter for an energy storage system with galvanic isolation[J]. IEEE Trans. on Power Electronics, 2007, 22(6): 2299-2306. [8] 赵彪,于庆广,孙伟欣,双重移相控制的双向全桥DC-DC变换器及其功率回流特性分析[J]. 中国电机工程学报,2012, 32(12): 43-50. [9] MYOUNGHO K, ROSEKEIT M, et al. A dual-phase- shift control strategy for dual-active-bridge DC-DC converter in wide voltage range[C]. ICPE & ECCE, Jeju, 2011: 364-371. [10] Hua bai, Chris Mi. Eliminate reactive power and increase system efficiency of isolated bidirectional dual-active-bridge DC-DC converters using novel dual-phase-shift control[J]. IEEE Trans. on Power Electronics, 2008, 23(6): 2905-2314. [11] B. zhao, Q, Song, W. Liu. Power characterization of isolated bidirectional dual-active-bridge DC-DC converter with dual-phase-shift control[J]. IEEE Trans. on Power Electronics, 2012, 27(9): 4172-4176. [12] B. zhao, Q, Song, W. Liu. Current-stress-optimized switching strategy of isolated bidirectional DC-DC converter with dual-phase-shift control[J]. IEEE Trans. on Power Electronics,2013,60(10):4458-4467. [13] 董亦斌,吴峂,金新民,等. 双向DC/DC变换器的拓扑研究[J]. 中国电机工程学报,2007,27(13):81-86. [14] B. zhao, Q, Song, W. Liu. Efficiency characterization and optimization of isolated bidirectional DC-DC converter based on dual-phase-shift control for DC distribution application[J]. IEEE Trans. on Power Electronics,2013, 28(4): 1711 -1726. [15] ALONSO A R, SEBASTIAN J, et al. An overall study of a dual active bridge for bidirectional DC/DC conversion[C]. ECCE, Atlanta, GA, 2010: 1129-1135.