Influence of Sandstorm Environment on the Discharge Characteristics of Rod-Plate Gap under Switching Impulse at High Altitude Area
Lü Fangcheng, Wang Hao, Geng Jianghai, Feng Juenan, Cui Yuhang
Key Laboratory of Power Transmission and Transformation Equipment Safety Defense of Hebei Province North China Electric Power University Baoding 071003 China
Abstract:The deserts, Gobi, and wasteland areas in northwest China have abundant solar and wind energy resources. Due to the uneven distribution of energy and load centers, ultra-high voltage transmission lines are needed to transport electricity to the eastern regions. However, frequent sandstorms pose a serious threat to the safe operation of the power grid in these areas. When sandstorm weather occurs, the two-phase flow of sandstorms will undergo electrification. Existing conclusions indicate that electrified sandstorms will seriously affect the discharge development of gaps, and the discharge characteristics of air gaps will become more complex. However, current research has not fully considered the influence of sandstorm parameters such as wind speed, sand particle size, concentration and charge on the discharge voltage of air gaps, which cannot meet the requirements of insulation design. In order to explore the influence of sandstorm environment on the insulation characteristics of gaps, this study selected multiple on-site sampling points with frequent sandstorm disasters. Through investigation and sampling, real wind and sand parameters in the desert of Qinghai Province were obtained, and a set of sandstorm environment simulation test devices was independently designed and manufactured. Wind speed, sand particle size, concentration, and charge-to-mass ratio were calibrated using equipment such as anemometers, sand screening machines, and high resistance meters to reproduce the real sandstorm environment. Then, by adjusting the combination of the above parameters, positive switching impulse discharge tests were conducted on the 1 m rod-plate gap in the 2 200 m altitude area of Qinghai Province under different sandstorm environmental conditions to obtain the gap discharge characteristics. Subsequently, the relevant mechanisms were analyzed to provide scientific basis for the insulation design of electrical equipment. The experimental results show that both in sand free environment and sandstorm environment, the 50% discharge voltage of the rod-plate gap decreases. Among them, in a sand free environment, the gap discharge voltage drops the most at a wind speed of 15 m/s, with a decrease of 4.25%. In a sandstorm environment, the discharge voltage drops the most when the wind speed is 15 m/s, the sand particle size is 250~500 μm, the concentration is 500 mg/m3, and the charge-to-mass ratio is -200 μC/kg, with a decrease of up to 11.02%. The standard deviation is less than 3% of the discharge voltage, indicating high data reliability. It can be concluded that the adverse effects on the gap insulation strength are more significant in sandstorm environments. Due to the coexistence of promoting and inhibiting effects of wind and sand flow on the development of discharge during the discharge process, the discharge voltage curve in the experiment shows nonlinear changes. In addition, wind and sand flow will advance the start time of the leader, accelerate the development speed of the leader, and overall the sandstorm environment will lead to a serious decrease in the insulation strength of the gap. When designing insulation in areas with frequent sandstorm disasters, it is necessary to fully consider the influence of sandstorm and increase the design margin. This study provides a theoretical basis and experimental support for the safe and stable operation of transmission lines in extreme environments. Future research can expand the range of experimental parameter conditions and further reveal the microscopic processes of gap discharge under sandstorm weather by combining other advanced methods.
律方成, 王皓, 耿江海, 冯觉楠, 崔宇航. 高海拔地区风沙环境对棒-板间隙操作冲击放电特性的影响研究[J]. 电工技术学报, 2026, 41(21): 7433-7446.
Lü Fangcheng, Wang Hao, Geng Jianghai, Feng Juenan, Cui Yuhang. Influence of Sandstorm Environment on the Discharge Characteristics of Rod-Plate Gap under Switching Impulse at High Altitude Area. Transactions of China Electrotechnical Society, 2026, 41(21): 7433-7446.
[1] 李海啸, 程强, 周林, 等. 大型可再生能源电站系统电压分布式非凸优化方法[J]. 电工技术学报, 2025, 40(22): 7399-7417. Li Haixiao, Cheng Qiang, Zhou Lin, et al.Distributed non-convex optimization method for system-wide voltage of large-scale renewable energy power plants[J]. Transactions of China Electrotechnical Society, 2025, 40(22): 7399-7417. [2] 唐宇, 胡光, 刘永江, 等. 基于特征子系统的跟网/构网设备混合外送系统小干扰稳定性分析[J]. 电工技术学报, 2025, 40(9): 2766-2779. Tang Yu, Hu Guang, Liu Yongjiang, et al.Small-signal stability analysis method for hybrid grid-following/grid-forming delivery systems based on eigen-subsystem[J]. Transactions of China Electro-technical Society, 2025, 40(9): 2766-2779. [3] 王祥宇, 辛焕海, 傅闯, 等. 考虑实际工况的新能源经柔性直流送出系统强度评估[J]. 电工技术学报, 2025, 40(15): 4708-4721. Wang Xiangyu, Xin Huanhai, Fu Chuang, et al.System voltage support strength evaluation for renewables HVDC transmission system considering operating condition[J]. Transactions of China Electro-technical Society, 2025, 40(15): 4708-4721. [4] 李伟, 叶昶, 李乐颖, 等. 沙戈荒风光储场站开关柜局部放电高频感知技术[J]. 高压电器, 2025, 61(3): 52-62. Li Wei, Ye Chang, Li Leying, et al.High-frequency sensing technology of partial discharge of switchgear cabinet for wind solar & energy storage stations in Gobi Deserts[J]. High Voltage Apparatus, 2025, 61(3): 52-62. [5] 蔡胜, 徐振钦, 谢云云, 等. 计及冷负荷启动时变特性的弹性配电网供电恢复[J]. 电工技术学报, 2025, 40(1): 139-151. Cai Sheng, Xu Zhenqin, Xie Yunyun, et al.A service restoration method for resilient distribution systems considering time-varying characteristic of cold load pickup[J]. Transactions of China Electrotechnical Society, 2025, 40(1): 139-151. [6] 万海洋, 刘文霞, 石庆鑫, 等. 城市电网灾后应急资源的集中匹配-分布调度策略[J]. 电工技术学报, 2024, 39(23): 7463-7480. Wan Haiyang, Liu Wenxia, Shi Qingxin, et al.A post-disaster centralized matching and decentralized dispatch strategy for emergency resources in urban power network[J]. Transactions of China Electro-technical Society, 2024, 39(23): 7463-7480. [7] 刘炯, 王劲, 梁明, 等. 高海拔条件下沙尘暴天气对线-板间隙工频击穿电压的影响试验研究[J]. 绝缘材料, 2022, 55(10): 99-106. Liu Jiong, Wang Jin, Liang Ming, et al.Experimental study on influence of dust storm weather on power frequency breakdown voltage of line-board gap under high altitude[J]. Insulating Materials, 2022, 55(10): 99-106. [8] 朱胜龙, 罗沙, 康健, 等. 导电微粒在稍不均匀场中荷电运动的离散元算法开发[J]. 高压电器, 2024, 60(4): 146-154, 164. Zhu Shenglong, Luo Sha, Kang Jian, et al.Development of DEM for conductive particulate charge and motion under slightly non-uniform electrical field[J]. High Voltage Apparatus, 2024, 60(4): 146-154, 164. [9] Gill E W B. Frictional electrification of sand[J]. Nature, 1948, 162(4119): 568-569. [10] Latham J.The electrification of snowstorms and sandstorms[J]. Quarterly Journal of the Royal Meteorological Society, 1964, 90(383): 91-95. [11] 郑晓静, 黄宁, 周又和. 风沙运动的沙粒带电机理及其影响的研究进展[J]. 力学进展, 2004, 34(1): 77-86. Zheng Xiaojing, Huang Ning, Zhou Youhe.Advances in investigation on electrification of wind-blown sands and its effects[J]. Advances in Mechanics, 2004, 34(1): 77-86. [12] Freier G D.The electric field of a large dust devil[J]. Journal of Geophysical Research, 1960, 65(10): 3504. [13] 鲁录义, 顾兆林, 罗昔联, 等. 一种风沙运动的颗粒动力学静电起电模型[J]. 物理学报, 2008, 57(11): 6939-6945. Lu Luyi, Gu Zhaolin, Luo Xilian, et al.An electrostatic dynamic model for wind-blown sand systems[J]. Acta Physica Sinica, 2008, 57(11): 6939-6945. [14] Eigen M, De Maeyer L.Self-dissociation and protonic charge transport in water and[J]. Proceedings of the Royal Society of London Series A Mathematical and Physical Sciences, 1958, 247(1251): 505-533. [15] 律方成, 刘畅, 丁玉剑. 沙尘环境中棒: 板间隙电场分布仿真及放电特性分析[J]. 高压电器, 2018, 54(2): 1-6. Lü Fangcheng, Liu Chang, Ding Yujian.Simulation of electric field distribution and analysis of discharge characteristics for rod-plane air gap with the presence of sandstorm[J]. High Voltage Apparatus, 2018, 54(2): 1-6. [16] Qureshi M I, Al-Arainy A R, Malik N H. Performance of rod-rod gaps in the presence of dust particles under lightning impulses[J]. IEEE Transactions on Power Delivery, 1991, 6(2): 706-714. [17] Al-Arainy A A, Malik N H, Qureshi M I. Influence of sand/dust contamination on the breakdown of asymmetrical air gaps under lightning impulses[J]. IEEE Transactions on Electrical Insulation, 1992, 27(2): 193-206. [18] Qureshi M I, Al-Arainy A A, Malik N H. Performance of rod-rod gaps in the presence of dust particles under standard switching impulses[J]. IEEE Transactions on Power Delivery, 1993, 8(3): 1045-1051. [19] 邓鹤鸣, 何正浩, 马军, 等. 沙尘天气下大沙粒对放电发展的影响[J]. 高电压技术, 2010, 36(5): 1246-1252. Deng Heming, He Zhenghao, Ma Jun, et al.Effect of large sanddust particles on discharge development in sand dust weather[J]. High Voltage Engineering, 2010, 36(5): 1246-1252. [20] 王建, 涂志飞, 章卓雨, 等. 沙尘环境下棒-板间隙交流放电特性研究[J]. 中国电力, 2020, 53(5): 63-68, 88. Wang Jian, Tu Zhifei, Zhang Zhuoyu, et al.AC discharge characteristics of rod plate gaps in sand dust environment[J]. Electric Power, 2020, 53(5): 63-68, 88. [21] 刘云鹏, 黄志成, 耿江海, 等. 沙粒荷电测量系统设计及沙粒荷电量测量仿真[J]. 中国电机工程学报, 2019, 39(20): 6148-6158. Liu Yunpeng, Huang Zhicheng, Geng Jianghai, et al.Sand charge measurement system design and sand charge measurement simulation[J]. Proceedings of the CSEE, 2019, 39(20): 6148-6158. [22] 张重远, 毕腾, 耿江海, 等. 荷电沙尘对棒-板短空气间隙工频击穿电压影响的试验研究[J]. 华北电力大学学报(自然科学版), 2019, 46(4): 39-45. Zhang Zhongyuan, Bi Teng, Geng Jianghai, et al.Experiment on influence of charged dust on power frequency breakdown voltage of rod-plate short air gap[J]. Journal of North China Electric Power University, 2019, 46(4): 39-45. [23] 王建, 涂志飞, 陈彬, 等. 沙尘环境下棒-板间隙的雷电冲击击穿特性[J]. 高电压技术, 2020, 46(3): 1012-1017. Wang Jian, Tu Zhifei, Chen Bin, et al.Effect of sand and dust on lightning pulse breakdown characteristics in bar-plate air gap[J]. High Voltage Engineering, 2020, 46(3): 1012-1017. [24] 孙传铭, 张作钦, 范超, 等. 风沙环境下绝缘子闪络特性及机理研究[J]. 高压电器, 2021, 57(10): 182-188. Sun Chuanming, Zhang Zuoqin, Fan Chao, et al.Study on flashover characteristics and mechanism of insulator in wind-sand environment[J]. High Voltage Apparatus, 2021, 57(10): 182-188. [25] 毕腾, 康钧, 王生富, 等. 沙尘条件下电极布置对棒-棒短空气间隙工频放电特性的影响[J]. 高压电器, 2021, 57(4): 10-14, 27. Bi Teng, Kang Jun, Wang Shengfu, et al.Influence of electrode arrangement on power-frequency discharge characteristics of rod-rod short air gap under sand dust conditions[J]. High Voltage Apparatus, 2021, 57(4): 10-14, 27. [26] 张重远, 李星辰, 马旭东, 等. 高海拔沙尘环境对典型长间隙操作冲击放电特性的影响[J]. 科学技术与工程, 2021, 21(11): 4478-4485. Zhang Zhongyuan, Li Xingchen, Ma Xudong, et al.Influence of sand and dust environment in high altitude area on impulse discharge characteristics of typical long gap operation[J]. Science Technology and Engineering, 2021, 21(11): 4478-4485. [27] GB/T 20480—2025 沙尘天气等级[S]. [28] Hagen L J, Skidmore E L.Wind erosion and visibility problems[J]. Transactions of the ASAE, 1977, 20(5): 898-903. [29] 钱正安, 宋敏红, 李万元. 近50年来中国北方沙尘暴的分布及变化趋势分析[J]. 中国沙漠, 2002, 22(2): 106-111. Qian Zheng’an, Song Minhong, Li Wanyuan.Analyses on distributive variation and forecast of sand-dust storms in recent 50 years in North China[J]. Journal of Desert Research, 2002, 22(2): 106-111. [30] 万本太, 康晓风, 张建辉, 等. 基于颗粒物浓度的沙尘天气分级标准研究[J]. 中国环境监测, 2004, 20(3): 8-11. Wan Bentai, Kang Xiaofeng, Zhang Jianhui, et al.Research on classification of dust and sand storm basic on particular concentration[J]. Environmental Monitoring in China, 2004, 20(3): 8-11. [31] Schmidt D S, Schmidt R A, Dent J D.Electrostatic force on saltating sand[J]. Journal of Geophysical Research: Atmospheres, 1998, 103(D8): 8997-9001. [32] 黄宁, 郑晓静. 风沙流中沙粒带电现象的实验测试[J]. 科学通报, 2000, 45(20): 2232-2235. [33] 屈建军, 言穆弘, 董光荣, 等. 沙尘暴起电的风洞模拟实验研究[J]. 中国科学(D辑: 地球科学), 2003, 33(6): 593-601. [34] Ye Qizheng, Li Jin, Zhang Jiacong.A dipole-enhanced approximation for a dielectric mixture[J]. Journal of Electrostatics, 2004, 61(2): 99-106. [35] GB/T 16927.1—2011 高电压试验技术第1部分:一般定义及试验要求[S]. [36] 蒋兴良, 于亮, 苑吉河, 等. 低气压棒-板间隙操作冲击放电特性及电压校正[J]. 高电压技术, 2007, 33(11): 70-74. Jiang Xingliang, Yu Liang, Yuan Jihe, et al.Switching impulse discharge performance and voltage correction of rod-plane air gaps at low atmospheric pressure[J]. High Voltage Engineering, 2007, 33(11): 70-74. [37] Halbritter J. On contamination on electrode surfaces and electric field limitations[J]. IEEE Transactions on Electrical Insulation, 1985, EI-20(4): 671-681. [38] Gallo C F, Lama W L. Classical electrostatic description of the work function and ionization energy of insulators[J]. IEEE Transactions on Industry Applications, 1976, IA-12(1): 7-11. [39] Babaeva N Y, Bhoj A N, Kushner M J.Streamer dynamics in gases containing dust particles[J]. Plasma Sources Science and Technology, 2006, 15(4): 591-602.