Abstract:In the medium-voltage high-power isolated DC-DC converter with low switching frequency, the challenge arises with the DC-bias problem of the medium-frequency transformer (MFT). Based on the three-level phase-shift full bridge topology, the harmonic voltage of the primary winding in MFT is calculated. Then, considering the voltage-current double close-loop control strategy of the DC/DC converter, the relationship between the DC component of the voltage on the MFT’s primary winding and the fluctuant phase-shift angle of the controller is analyzed, and the effects of the control-frequency on the DC component of the primary voltage are analyzed. An experiment platform was established to compare the DC-bias performances of the MFT under different frequencies. The experimental results validate the DC-bias suppression of the proposed method.
王瑞田, 肖飞, 范学鑫, 杨国润, 张新生. 三电平移相全桥直流变换器的变压器直流偏置分析与抑制[J]. 电工技术学报, 2019, 34(16): 3345-3354.
Wang Ruitian, Xiao Fei, Fan Xuexin, Yang Guorun, Zhang Xinsheng. Analysis and Suppression of Transformer DC-Bias for DC-DC Converter with Three-Level Phase-Shift Full-Bridge Topology. Transactions of China Electrotechnical Society, 2019, 34(16): 3345-3354.
[1] Yang Guorun, Xiao Fei, Fan Xuexin, et al.Three- phase three-level phase shifted PWM DC-DC con- verter for electric ship MVDC application[J]. IEEE Journal of Emerging and Selected Topics in Power Electronics, 2017, 5(1): 162-170. [2] 张雪垠, 徐永海, 肖湘宁. 适用于中高压配电网的高功率密度谐振型级联H桥固态变压器[J]. 电工技术学报, 2018, 33(2): 310-321. Zhang Xueyin, Xu Yonghai, Xiao Xiangning.A high power density resonance cascaded H-bridge solid- state transformer for medium and high voltage distri- bution network[J]. Transactions of China Electro- technical Society, 2018, 33(2): 310-321. [3] 李敏远, 彭博. 400Hz正弦波逆变电源偏磁控制系统研究[J]. 西安理工大学学报, 2009, 25(2): 169-173. Li Minyuan, Peng Bo.A study of magnetic-bias control system for 400Hz sine-wave inverters[J]. Journal of Xi’an University of Technology, 2009, 25(2): 169-173. [4] 吴华波. 太阳能并网逆变电源变压器直流偏磁的抑制[J]. 电力电子技术, 2009, 43(7): 58-59. Wu Huabo.Restraining of DC bias transformer magnetization in solar energy grid inverter[J]. Power Electronics, 2009, 43(7): 58-59. [5] 陈志伟, 白保东, 陈德志, 等. 电力变压器直流偏磁现象形成机理及一种抑制措施的研究[J]. 电工技术学报, 2015, 30(14): 208-214. Chen Zhiwei, Bai Baodong, Chen Dezhi, et al.Research on the formation mechanism and suppression method of transformer DC bias[J]. Transactions of China Electrotechnical Society, 2015, 30(14): 208-214. [6] Takasu N, Oshi T, Miyawaki F, et al.An experi- mental analysis of DC excitation of transformers by geomagnetically induced currents[J]. IEEE Transa- ctions on Power Delivery, 1994, 9(2): 1173-1182. [7] 赵志刚, 程志光, 刘福贵, 等. 基于漏磁通补偿的导磁钢板直流偏磁杂散损耗特性模拟[J]. 电工技术学报, 2015, 30(8): 38-44. Zhao Zhigang, Cheng Zhiguang, Liu Fugui, et al.Modeling of the DC-biased stray-field loss of magnetic steel plate based on compensator of leakage flux[J]. Transactions of China Electrotechnical Society, 2015, 30(8): 38-44. [8] Picher P, Bolduc L, Dutil A, et al.Study of the acceptable DC current limit in core-form power transformers[J]. IEEE Transactions on Power Delivery, 1997, 12(1): 257-265. [9] 王佳音, 白保东, 刘宏亮, 等. 直流偏磁对变压器振动噪声的影响[J]. 电工技术学报, 2015, 30(8): 56-61. Wang Jiayin, Bai Baodong, Liu Hongliang, et al.Research on vibration and noise of transformers under DC bias[J]. Transactions of China Electro- technical Society, 2015, 30(8): 57-61. [10] 曹林, 何金良, 张波. 直流偏磁状态下电力变压器铁心动态磁滞损耗模型及验证[J]. 中国电机工程学报, 2008, 28(24): 141-146. Cao Lin, He Jinliang, Zhang Bo.Dynamic hysteresis loss model of power transformer under DC current biasing and its verification[J]. Proceedings of the CSEE, 2008, 28(24): 141-146. [11] 李长云, 刘亚魁. 直流偏磁条件下变压器铁心磁化特性的Jiles-Atherton修正模型[J]. 电工技术学报, 2017, 32(19): 193-201. Li Changyun, Liu Yakui.Modified Jiles-Atherton model of transformer iron core magnetization characteristics with DC bias[J]. Transactions of China Electrotechnical Society, 2017, 32(19): 193-201. [12] 李泓志, 崔翔, 卢铁兵, 等. 变压器直流偏磁的电路-磁路模型[J]. 中国电机工程学报, 2009, 29(27): 119-125. Li Hongzhi, Cui Xiang, Lu Tiebing, et al.Electric circuit and magnetic circuit combined model of DC biased power transformer[J]. Proceedings of the CSEE, 2009, 29(27): 119-125. [13] Bolduc L, Gaudreau A, Dutil A.Saturation time of transformers under DC excitation[J]. Electric Power Systems Research, 2000, 56(2): 95-102. [14] Miyagi D, Yoshida T, Nakano M, et al.Development of measuring equipment of DC-biased magnetic properties using open-type single-sheet tester[J]. IEEE Transactions on Magnetics, 2006, 42(10): 2846-2848. [15] 段善旭, 刘邦银, 彭力, 等. 全数字化逆变电源输出变压器偏磁问题与抑制[J]. 高电压技术, 2003, 29(10): 1-3. Duan Shanxu, Liu Bangyin, Peng Li, et al.The analysis and eliminating techniques of magnetic bias for output transformer in the fully digitized intermediate frequency inverters[J]. High Voltage Engineering, 2003, 29(10): 1-3. [16] 赵彪, 宋强, 刘文华, 等. 用于柔性直流配电的高频链直流固态变压器[J]. 中国电机工程学报, 2014, 34(25): 4295-4303. Zhao Biao, Song Qiang, Liu Wenhua, et al.High- frequency-link DC solid state transformers for flexible DC distribution[J]. Proceedings of the CSEE, 2014, 34(25): 4295-4303. [17] 谢桢, 付立军, 肖飞, 等. 三电平直流变换器平衡中点电位的双移相 PWM 控制研究[J]. 西安交通大学学报, 2013, 47(4): 64-72. Xie Zhen, Fu Lijun, Xiao Fei, et al.Neutral-point balancing double phase-shift PWM controller for three-level DC-DC converter[J]. Journal of Xi’an Jiaotong University, 2013, 47(4): 64-72.