电工技术学报  2020, Vol. 35 Issue (8): 1776-1786    DOI: 10.19595/j.cnki.1000-6753.tces.190143
电力系统 |
考虑换相失败相互影响的多馈入高压直流系统换相失败判断方法
许汉平1, 杨炜晨2, 张东寅1, 苗世洪2, 王怡聪1
1. 国网湖北省电力有限公司经济技术研究院 武汉 430077;
2. 华中科技大学电气与电子工程学院强电磁工程与新技术国家重点实验室电力安全与高效湖北省重点实验室 武汉 430074
Commutation Failure Judgment Method for Multi-Infeed HVDC Systems Considering the Interaction of Commutation Failures
Xu Hanping1, Yang Weichen2, Zhang Dongyin1, Miao Shihong2, Wang Yicong1
1. Economics & Technology Research Institute State Grid Hubei Electric Power Company Wuhan 430077 China;;
2. State Key Laboratory of Advanced Electromagnetic Engineering and Technology Hubei Electric Power Security and High Efficiency Key Laboratory School of Electrical and Electronic Engineering Huazhong University of Science and Technology Wuhan 430074 China
全文: PDF (31449 KB)   HTML
输出: BibTeX | EndNote (RIS)      
摘要 在多馈入高压直流系统(MIDC)中,逆变站换相失败的相互影响是引发换相失败传递的重要因素。该文详细分析逆变站换相失败期间的暂态特性,并根据开关函数模型及动态相量理论推导直流系统向交流系统注入的换相失败分量;进而研究在交流系统故障及换相失败双重影响下各逆变站换相电压的解析计算方法;在此基础上,通过对比各换流阀的最大换相面积与其关断所需的最小换相面积,提出针对多馈入高压直流系统的换相失败判断分析方法;最后,通过所建多馈入高压直流系统模型的仿真结果,验证了该文方法的有效性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
许汉平
杨炜晨
张东寅
苗世洪
王怡聪
关键词 多馈入高压直流系统相互影响换相失败开关函数换相面积    
Abstract:In the multi-infeed high-voltage DC system (MIDC), the interaction among inverter stations is an important factor that triggers the propagation of commutation failure. In this paper, the transient characteristics of inverter station during commutation failure are analyzed in detail, and the commutation failure component is derived by the switching function model and the dynamic phasor theory. Then, the analytical calculation method is studied to reflect the commutation voltage of each inverter station, considering the mutual influence of AC system fault and commutation failure. On this basis, by comparing the maximum commutation area of each converter valve with the minimum commutation area required for turning off, a commutation failure judgement method is proposed. Finally, the simulation results verify the proposed method.
Key wordsMulti-infeed high-voltage DC system    mutual influence    commutation failure    switching function    commutation area   
收稿日期: 2019-02-03      出版日期: 2020-04-24
PACS: TM721  
基金资助:国网湖北省电力有限公司经济技术研究院科技资助项目(SGHBJY00JHJS1800026)
通讯作者: 杨炜晨 男,1995年生,博士研究生,研究方向为直流输电运行与控制。E-mail: yangwc@hust.edu.cn   
作者简介: 许汉平 男,1969年生,硕士,研究方向为电力系统运行及控制。E-mail: xuhping@sina.com
引用本文:   
许汉平, 杨炜晨, 张东寅, 苗世洪, 王怡聪. 考虑换相失败相互影响的多馈入高压直流系统换相失败判断方法[J]. 电工技术学报, 2020, 35(8): 1776-1786. Xu Hanping, Yang Weichen, Zhang Dongyin, Miao Shihong, Wang Yicong. Commutation Failure Judgment Method for Multi-Infeed HVDC Systems Considering the Interaction of Commutation Failures. Transactions of China Electrotechnical Society, 2020, 35(8): 1776-1786.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/10.19595/j.cnki.1000-6753.tces.190143          https://dgjsxb.ces-transaction.com/CN/Y2020/V35/I8/1776