电工技术学报  2018, Vol. 33 Issue (zk2): 461-471    DOI: 10.19595/j.cnki.1000-6753.tces.L80051
电机与电器 |
高速列车电磁接触器可靠性评估方法
刘建强1, 陈爱峰1, 闫一凡2, 张铭1, 齐洪峰2
1. 北京交通大学电气工程学院 北京 100044;
2. 中车工业研究院有限公司技术研究部 北京 100070
Reliability Evaluation Method of Electromagnetic Contactor Used in High-Speed Train
Liu Jianqiang1, Chen Aifeng1, Yan Yifan2, Zhang Ming1, Qi Hongfeng2
1. School of Electrical Engineering Beijing Jiaotong University Beijing 100044 China;
2. Technical Research Department CRRC Industry Research Institute Co. Ltd Beijing 100070 China
全文: PDF (58487 KB)  
输出: BibTeX | EndNote (RIS)      
摘要 电磁接触器的状态对高速列车的运行安全至关重要。目前高速列车中电磁接触器缺乏有效的测试与评估方法,导致接触器的可靠性状态信息未知,给高速列车的正常安全运行带来了极大隐患。针对这一问题,首先对高速列车电磁接触器的失效机理进行分析,进而提出一种接触器可靠性评估方法。该方法建立接触器触点间隙的退化模型,通过接触器有限元及动力学仿真模型的分析,推导超程时间的退化模型,进而得到接触器剩余寿命的预测模型。为了验证上述方法的有效性,设计并搭建接触器可靠性测试试验平台。基于西门子3RT1017-2KF41电磁接触器开展可靠性寿命试验,利用接触器剩余寿命预测模型对接触器的剩余寿命进行预测。结果表明,所提出的高速列车电磁接触器可靠性评估方法能够对接触器的剩余寿命进行准确预测,为高速列车电磁接触器的状态监测及维护维修提供了重要参考。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
刘建强
陈爱峰
闫一凡
张铭
齐洪峰
关键词 电磁接触器可靠性超程时间退化模型剩余寿命    
Abstract:The state of electromagnetic contactor is very important for the safe and normal operation of the high-speed train. At present, there is a lack of testing and evaluation methods for the state of electromagnetic contactor in high-speed train. The state of electromagnetic contactor is uncertain and uncontrollable, which raises potential security problems in high-speed train operation. To solve this problem, the failure mechanism of the high-speed train electromagnetic contactor is analyzed. According to the analysis of contactor failure mechanism, the reliability evaluation method of contactor is proposed. The method establishes the contact gap degradation model of the contactor. Through the finite element analysis of the contactor and the dynamic simulation model, the degradation model of the overtravel time is deduced, and then the prediction model of the remaining life of the contactor is obtained. In order to verify the effectiveness of the reliability evaluation method, a contactor reliability test platform was designed and built. The reliability life test was carried out based on Siemens 3RT1017-2KF41 electromagnetic contactor. The remaining life of the contactor is predicted with the prediction model of the residual life. The results shows that the proposed method is effective to predict the residual life of the relay, which provides important reference for the condition monitoring and maintenance of the electromagnetic relay in high-speed train.
Key wordsElectromagnetic contactor    reliability    super-path time    degradation model    residual life   
收稿日期: 2018-06-06      出版日期: 2019-02-15
PACS: TM581.3  
基金资助:国家重点研发计划资助项目(2017YFB1201304-04)
通讯作者: 刘建强 男,1981年生,副教授,研究方向为电力电子与电力传动。E-mail: liujianqiang@bjtu.edu.cn   
作者简介: 陈爱峰 男,1993年生,硕士研究生,研究方向为电力电子与电力传动。E-mail: 16121418@bjtu.edu.cn
引用本文:   
刘建强, 陈爱峰, 闫一凡, 张铭, 齐洪峰. 高速列车电磁接触器可靠性评估方法[J]. 电工技术学报, 2018, 33(zk2): 461-471. Liu Jianqiang, Chen Aifeng, Yan Yifan, Zhang Ming, Qi Hongfeng. Reliability Evaluation Method of Electromagnetic Contactor Used in High-Speed Train. Transactions of China Electrotechnical Society, 2018, 33(zk2): 461-471.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/10.19595/j.cnki.1000-6753.tces.L80051          https://dgjsxb.ces-transaction.com/CN/Y2018/V33/Izk2/461