计及保护信息的电力系统暂态稳定裕度解析算法
刘九良1, 王彤1, 朱劭璇1, 王增平1, 唐俊刺2
1. 新能源电力系统国家重点实验室(华北电力大学) 北京 102206;
2. 国网辽宁省电力有限公司 沈阳 110006
An Analytic Method for Power System Transient Stability Margin Considering Protection Information
Liu Jiuliang1, Wang Tong1, Zhu Shaoxuan1, Wang Zengping1, Tang Junci2
1. State Key Laboratory for Alternate Electrical Power System with Renewable Energy SourcesNorth China Electric Power University Beijing 102206 China;
2. State Grid Liaoning Electric Power Supply Co. Ltd Shenyang 110006 China
全文: PDF (2036 KB)   HTML
输出: BibTeX | EndNote (RIS)      
摘要 电力系统暂态稳定裕度与故障因素息息相关,保护动作信息包含故障类型、故障位置以及故障持续时间等有效信息。该文提出一种计及保护信息的暂态稳定裕度解析算法。首先,计算不对称短路的附加阻抗,建立含附加阻抗的多机系统网络简化模型。然后,将转子运动方程等效为单机无穷大母线系统形式,提出发电机聚合功角的分段模型,在此基础上,推导暂态稳定裕度解析表达式。利用在线获取的保护动作信息,快速计算故障后系统的暂态稳定裕度,并通过求取暂态稳定裕度的偏导,分别分析不对称故障下故障位置和故障持续时间对暂态稳定裕度的影响。最后,在四机两区系统和新英格兰系统中进行仿真分析,仿真结果证明了该方法的准确性和有效性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
刘九良
王彤
朱劭璇
王增平
唐俊刺
关键词 暂态稳定裕度不对称故障功角分段模型解析法保护信息    
Abstract:The transient stability margin of power system is closely related to the fault factors. The protection information includes effective information such as fault type, fault location and fault duration. This paper proposes an analytical method for calculating transient stability margin considering protection information. Firstly, the additional impedance of unbalanced fault is calculated, and the simplified model of multi-machine system network with additional impedance is established. Then, the rotor motion equation is equivalent to the one-machine infinite-bus system, and the piecewise models of generator aggregate power angles are further put forward. On this basis, the analytical expression of transient stability margin is derived. The transient stability margin of power system after fault can be quickly calculated by the protection information obtained online. And the effects of fault location and fault duration on the stability margin under unbalanced fault are analyzed by calculating the partial derivative of the stability margin expression. Finally, the simulations are carried out in the four-machine two-area system and the New England system, respectively. The accuracy and effectiveness of the proposed method are verified by the simulation results.
Key wordsTransient stability margin    unbalanced fault    the piecewise models of generator angles    analytical method    protection information   
收稿日期: 2019-01-28      出版日期: 2020-02-12
PACS: TM712  
基金资助:国家自然科学基金(51637005)、中央高校基本科研业务费专项资金(2018MS006)和国家电网公司科技项目(SGTYHT/17-JS-199)资助
通讯作者: 王 彤 女,1985年生,博士,副教授,研究方向为新能源电力系统稳定分析与控制,暂态稳定分析、评估与紧急控制。E-mail:hdwangtong@126.com   
作者简介: 刘九良 男,1994年生,硕士研究生,研究方向为暂态稳定分析、评估与紧急控制。E-mail:1207762256@qq.com
引用本文:   
刘九良, 王彤, 朱劭璇, 王增平, 唐俊刺. 计及保护信息的电力系统暂态稳定裕度解析算法[J]. 电工技术学报, 2020, 35(3): 542-552. Liu Jiuliang, Wang Tong, Zhu Shaoxuan, Wang Zengping, Tang Junci. An Analytic Method for Power System Transient Stability Margin Considering Protection Information. Transactions of China Electrotechnical Society, 2020, 35(3): 542-552.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/10.19595/j.cnki.1000-6753.tces.190116          https://dgjsxb.ces-transaction.com/CN/Y2020/V35/I3/542