Abstract:In view of the increase of geomagnetic storms invading the power grid in middle and low latitudes in recent years and the blackout accident in Quebec caused by strong geomagnetic storm, it is necessary to analyze the impact of geomagnetic storms on the stable operation of power system. Constrained by various factors, the power system often operates in a state of extreme stability. The geomagnetically induced current (GIC) causes an increase in the reactive power loss (GIC-Q) of the transformer. Whether the GIC-Q with the whole network clustering and volatility will increase the risk of system instability and whether the addition of the DC system will affect the anti-geomagnetic storm ability of the power grid has not been studied. From the perspective of power system stability, the probability distribution law of substation GIC-Q in long time scale is studied. Combined with the GIC benchmark network model, GIC-Q is added to the system on the basis of the original load, and the influence of geomagnetic storm on the probability stability of AC system and AC/DC hybrid system is analyzed.
王泽忠, 司远, 刘连光. 地磁暴对电力系统稳定性的影响[J]. 电工技术学报, 2022, 37(7): 1780-1788.
Wang Zezhong, Si Yuan, Liu Lianguang. Influence of Geomagnetic Storms on the Stability of Power System. Transactions of China Electrotechnical Society, 2022, 37(7): 1780-1788.
[1] Blake S P, Gallagher P T, McCauley J, et al. Geomagnetically induced currents in Irish power network during geomagnetic storms[J]. Space Weather, 2016, 14(12): 1136-1154. [2] 黄天超, 王泽忠. 地磁暴对直流输电逆变侧换相角及谐波的影响机理分析[J]. 电工技术学报, 2020, 35(16): 3377-3384. Huang Tianchao, Wang Zezhong.Mechanism analysis of geomagnetic storm on commutation angle and harmonic of invert side of HVDC transmission[J]. Transactions of China Electrotechnical Society, 2020, 35(16): 3377-3384. [3] Marshall R A, Smith E A, Francis M J, et al.A preliminary risk assessment of Australian region power network to space weather[J]. Space Weather, 2011, 9(10): 1-18. [4] 刘春明. 中低纬电网地磁感应电流及其评估方法研究[D]. 北京: 华北电力大学, 2009. [5] Barbosa C, Alves L, Caraballo R, et al.Analysis of geomagnetically induced currents at a low-latitude region over the solar cycles 23 and 24: comparison between measurements and calculations[J]. Journal of Space Weather and Space Climate, 2015, 5: A35. [6] Blake S P, Gallagher P T, McCauley J, et al. Geomagnetically induced currents in the Irish power network during geomagnetic storms[J]. Space Weather, 2016, 14(12): 1136-1154. [7] 杨培宏, 刘连光, 刘春明, 等. 地磁暴引起电网电压波动抑制策略[J]. 高电压技术, 2017, 43(5): 1707-1714. Yang Peihong, Liu Lianguang, Liu Chunming, et al.Strategy for restraining voltage fluctuation in power network caused by geomagnetic storm[J]. High Voltage Engineering, 2017, 43(5): 1707-1714. [8] 廖卫平, 张艳, 冯佳伟, 等. 考虑不对称故障影响的感应电动机负荷动态特性快速解析算法[J]. 电工技术学报, 2020, 35(19): 4183-4193. Liao Weiping, Zhang Yan, Feng Jiawei, et al.Fast analytical method for calculating the dynamic performance of induction-motor loads considering the effect of asymmetrical fault[J]. Transactions of China Electrotechnical Society, 2020, 35(19): 4183-4193. [9] 王泽忠, 黄天超. 特高压变压器地磁感应电流和无功功率关系的定量分析[J]. 电工技术学报, 2020, 35(22): 4709-4716. Wang Zezhong, Huang Tianchao.Quantitative analysis of geomagnetically induced current-Q relation of UHV transformer[J]. Transactions of China Electrotechnical Society, 2020, 35(22): 4709-4716. [10] Horton R, Boteler D, Overbye T J, et al.A test case for the calculation of geomagnetically induced current[J]. IEEE Transaction Power Delivery, 2012, 27(4): 2368-2373. [11] 王泽忠, 董博, 刘春明, 等. 华北地区大地电性结构三维建模及磁暴感应地电场有限元计算[J]. 电工技术学报, 2015, 30(3): 61-66. Wang Zezhong, Dong Bo, Liu Chunming, et al.Three-dimensional earth conductivity structure modeling in north China and calculation of geoelectromagnetic fields during geomagnetic disturbances based on finite element method[J]. Transactions of China Electrote-chnical Society, 2015, 30(3): 61-66. [12] 刘连光, 郭世晓, 魏恺, 等. 基于全节点模型的三华电网地磁感应电流计算[J]. 电网技术, 2014, 38(7): 1946-1952. Liu Lianguang, Guo Shixiao, Wei Kai, et al.Calculation of geomagnetically induced currents in interconnected north China-central China-east China power grid based on full-node GIC model[J]. Power System Technology, 2014, 38(7): 1946-1952. [13] 李冰, 王泽忠, 刘恪, 等. 特高压变压器直流偏磁对绕组电流的影响[J]. 电工技术学报, 2020, 35(7): 1422-1431. Li Bing, Wang Zezhong, Liu Ke, et al.Research on winding current of UHV transformer under DC-bias[J]. Transactions of China Electrotechnical Society, 2020, 35(7): 1422-1431. [14] 刘连光, 朱溪, 王泽忠, 等. 基于K值法的单相四柱式特高压主体变的GIC-Q损耗计算[J]. 高电压技术, 2017, 43(7):2 340-2348. Liu Lianguang, Zhu Xi, Wang Zezhong, et al.Calculation for reactive power loss of single-phase four limbs UHV transformer due to geomagnetically induced current with parameter K[J]. High Voltage Engineering, 2017, 43(7): 2340-2348. [15] 刘春明, 王红梅, 王璇. 多次磁暴下特高压电网GIC统计规律研究[J]. 中国电机工程学报, 2019, 39(15): 4606-4615. Liu Chunming, Wang Hongmei, Wang Xuan.Statistical analysis of geomagnetically induced current in UHV power grids under multiple geomagnetic storms[J]. Proceedings of the CSEE, 2019, 39(15): 4606-4615. [16] 刘佳. 大规模风电接入的电力系统小干扰稳定及控制方法研究[D]. 北京: 华北电力大学, 2019. [17] 郑安然, 郭春义, 殷子寒, 等. 提高弱交流系统下混合多端直流输电系统小干扰稳定性的控制参数优化调节方法[J]. 电工技术学报, 2020, 35(6): 1336-1345. Zheng Anran, Guo Chunyi, Yin Zihan, et al.optimal adjustment method of control parameters for improving small-signal stability of hybrid multi-terminal HVDC system under weak AC condition[J]. Transactions of China Electrotechnical Society, 2020, 35(6): 1336-1345.