Multi-Layer Tissue Structure Transcutaneous Electric Field Coupled Wireless Power Transfer System for Human Implantable Devices
Cai Chunwei1,2, Chen Tian3, Wu Shuai1,2, Jiao Yujie1, Liu Xichen1
1. School of New Energy Harbin Institute of Technology (Weihai) Weihai 264209 China; 2. Qingdao Research Institute Harbin Institute of Technology (Weihai) Qingdao 266109 China; 3. Wuhan Power Supply Company of State Grid Hubei Electric Power Co. Ltd Wuhan 430010 China
Abstract:Electric-field-coupled wireless power transfer (WPT) offers the advantages of low electro- magnetic interference, low eddy current loss, and lightweight coupler structures. However, current research on electric-field-coupled WPT for human implantable devices typically assumes a single-layer human-tissue model as the energy-transmission medium. In practical applications, the flexible film electrode, used as a receiver, is usually implanted between the skin and fat. Thus, the structure of multi-layer tissue has significant research potential for electric-field-coupled WPT. In this paper, a multi-layer tissue-structure transcutaneous electric- field-coupled WPT system is investigated from three aspects: circuit modeling, coupling device design, and safety assessment. To address the limitations of traditional circuit models in complex human environments, a precise human-tissue circuit model is developed. The dielectric properties of human tissues are studied using the fourth- order Cole-Cole model, and the tissue loss angle, which quantifies energy dissipation across frequencies, serves as the criterion for frequency selection. A multi-tissue-layer circuit model of the human body that incorporates current and voltage distributions is developed. Accordingly, the power distribution in the power transfer link and the system efficiency are analyzed to identify the parameters that affect the transcutaneous link's energy transfer performance. To address the specific requirements of the multi-layer tissue circuit model, the coupler is designed, and its transmission characteristics are investigated. Firstly, the insulation layer thickness is optimized using power transfer efficiency as the criterion. The insulation layer thickness is selected, and the resonant frequency is determined to be 3 MHz. Then, the S-S compensation circuit is designed to clarify the influence on the power transfer link. Ultimately, the power-transfer capacity of the designed coupler is examined. The results show that the designed coupler is insensitive to transmitter separation and to misalignment in the X and Y directions, making it suitable for subcutaneous implants. To ensure the safety of the transcutaneous power transfer link, a safety assessment is conducted on the designed coupler. Using IEEE C95.1 as the safety criterion, the safety assessment is based on the electric field's specific absorption rate in COMSOL. The energy transfer capabilities at different frequencies are compared. Subsequently, the tissue temperature rise is evaluated using the temperature field simulation. The tissue temperature rise during one hour of charging is under 0.789℃, which meets the IEEE C95.1 thermal safety regulations. An experimental platform using fresh pork is set up. The optimized coupler design is verified through comparative experiments with insulating layers of different thicknesses. The simulation, analytical calculation, and experimental results agree well with the proposed circuit model. The power delivered to the load is 107 mW, and the link efficiency is 45.48%, thereby verifying the excellent energy transmission capability of the designed coupler.
蔡春伟, 陈天, 武帅, 焦宇杰, 刘希琛. 多组织层结构经皮电场耦合的人体植入式设备无线电能传输系统[J]. 电工技术学报, 2026, 41(10): 3260-3272.
Cai Chunwei, Chen Tian, Wu Shuai, Jiao Yujie, Liu Xichen. Multi-Layer Tissue Structure Transcutaneous Electric Field Coupled Wireless Power Transfer System for Human Implantable Devices. Transactions of China Electrotechnical Society, 2026, 41(10): 3260-3272.
[1] 陈浩, 丘东元, 张波, 等. 植入式医疗设备无线供电技术综述[J]. 电源学报, 2025, 23(1): 188-199. Chen Hao, Qiu Dongyuan, Zhang Bo, et al.Overview of wireless power transfer technology for implantable medical devices[J]. Journal of Power Supply, 2025, 23(1): 188-199. [2] Cai Chunwei, Chen Tian, Ren Xiuyun, et al.Modeling and design of a transcutaneous resonant capacitive power transfer link for biomedical implants[J]. IEEE Transactions on Power Electronics, 2025, 40(2): 3726-3737. [3] 陈伟华, 黄雨琦, 闫孝姮, 等. 基于多频磁负超材料的心脏起搏器无线供能研究[J]. 电工技术学报, 2024, 39(16): 4931-4943. Chen Weihua, Huang Yuqi, Yan Xiaoheng, et al.Wireless energy supply for cardiac pacemaker based on multi-band magnetic negative metamaterial[J]. Transactions of China Electrotechnical Society, 2024, 39(16): 4931-4943. [4] Knecht O, Kolar J W.Performance evaluation of series-compensated IPT systems for transcutaneous energy transfer[J]. IEEE Transactions on Power Electronics, 2019, 34(1): 438-451. [5] Khalifeh J M, Zohny Z, MacEwan M, et al. Electrical stimulation and bone healing: a review of current technology and clinical applications[J]. IEEE Reviews in Biomedical Engineering, 2018, 11: 217-232. [6] Charthad J, Baltsavias S, Samanta D, et al.An ultrasonically powered implantable device for targeted drug delivery[C]//2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Orlando, FL, USA, 2016: 541-544. [7] Yoo J, Yan Long, Lee S, et al.A 5.2 mW self- configured wearable body sensor network controller and a 12 μW wirelessly powered sensor for a continuous health monitoring system[J]. IEEE Journal of Solid-State Circuits, 2010, 45(1): 178-188. [8] Baker M W.A low-power cochlear implant system[D]. Cambridge: Massachusetts Institute of Technology, 2007. [9] Lo Y K, Chen Kuanfu, Gad P, et al.A fully-integrated high-compliance voltage SoC for epi-retinal and neural prostheses[J]. IEEE Transactions on Biomedical Circuits and Systems, 2013, 7(6): 761-772. [10] Galkin B, Kibilda J, DaSilva L A. UAVs as mobile infrastructure: addressing battery lifetime[J]. IEEE Communications Magazine, 2019, 57(6): 132-137. [11] 尹杰, 刘博, 孙国兵, 等. 基于迁移学习和降噪自编码器-长短时间记忆的锂离子电池剩余寿命预测[J]. 电工技术学报, 2024, 39(1): 289-302. Yin Jie, Liu Bo, Sun Guobing, et al.Transfer learning denoising autoencoder-long short term memory for remaining useful life prediction of Li-ion batteries[J]. Transactions of China Electrotechnical Society, 2024, 39(1): 289-302. [12] Hauser R G.The growing mismatch between patient longevity and the service life of implantable cardioverter-defibrillators[J]. Journal of the American College of Cardiology, 2005, 45(12): 2022-2025. [13] 尹成科, 徐博翎. 植入式人工心脏无线电能传输研究进展[J]. 电工技术学报, 2015, 30(19): 103-109. Yin Chengke, Xu Boling.Wireless power transfer for implantable ventricular assistance: a review[J]. Trans- actions of China Electrotechnical Society, 2015, 30(19): 103-109. [14] Meng Miao, Kiani M.Design and optimization of ultrasonic wireless power transmission links for millimeter-sized biomedical implants[J]. IEEE Trans- actions on Biomedical Circuits and Systems, 2017, 11(1): 98-107. [15] Caverly R H.Breakthroughs in microwaves: increasing signal strength in swarms of wireless sensors: an interview with dr. Aydin babakhani[J]. IEEE Journal of Microwaves, 2021, 1(2): 532-539. [16] 陈伟华, 宋宇航, 闫孝姮, 等. 心脏起搏器无线电能传输LCC-LCC磁集成印刷螺旋线圈研究[J]. 电工技术学报, 2024, 39(17): 5289-5299. Chen Weihua, Song Yuhang, Yan Xiaoheng, et al.Research on wireless power transmission for cardiac pacemakers using LCC-LCC magnetic integrated printed spiral coil[J]. Transactions of China Elec- trotechnical Society, 2024, 39(17): 5289-5299. [17] Jow U M, Ghovanloo M.Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission[J]. IEEE Transactions on Biomedical Circuits and Systems, 2007, 1(3): 193-202. [18] Kiani M, Jow U M, Ghovanloo M.Design and optimization of a 3-coil inductive link for efficient wireless power transmission[J]. IEEE Transactions on Biomedical Circuits and Systems, 2011, 5(6): 579-591. [19] 周华康, 严仲明, 曹桂梅, 等. 基于柔性线圈的信能同链路分时传输系统[J/OL]. 电工技术学报, 1-10 [2026-02-12]. https://doi.org/10.19595/j.cnki.1000-6753.tces.251083. Zhou Huakang, Yan Zhongming, Cao Guimei, et al. flexible coil-based information-power co-link time- division transmission system[J/OL]. Transactions of China Electrotechnical Society, 1-10. [2026-02-12]. https://doi.org/10.19595/j.cnki.1000-6753.tces.251083. [20] 陈伟华, 刘岳鹏, 闫孝姮, 等. 心脏起搏器谐振式无线供能四匹配电容无功屏蔽[J]. 电工技术学报, 2025, 40(14): 4382-4394. Chen Weihua, Liu Yuepeng, Yan Xiaoheng, et al.Reactive shielding of four matching capacitors for resonant wireless power transfer in cardiac pace- makers[J]. Transactions of China Electrotechnical Society, 2025, 40(14): 4382-4394. [21] Al-Kalbani A I, Yuce M R, Redouté J M. A biosafety comparison between capacitive and inductive coupling in biomedical implants[J]. IEEE Antennas and Wire- less Propagation Letters, 2014, 13: 1168-1171. [22] 郑小瑶, 江彦伟, 疏许健, 等. 宇称-时间对称电场耦合无线电能传输系统电场分布特性研究[J]. 电源学报, 2024, 22(5): 60-66. Zheng Xiaoyao, Jiang Yanwei, Shu Xujian, et al.Study on electric-field distribution characteristics of parity-time symmetric electric-field coupled wireless power transfer system[J]. Journal of Power Supply, 2024, 22(5): 60-66. [23] Erfani R, Marefat F, Sodagar A M, et al.Modeling and experimental validation of a capacitive link for wireless power transfer to biomedical implants[J]. IEEE Transactions on Circuits and Systems II: Express Briefs, 2018, 65(7): 923-927. [24] Hossain A N M S, Mohseni P, Lavasani H M. Design and optimization of capacitive links for wireless power transfer to biomedical implants[J]. IEEE Transactions on Biomedical Circuits and Systems, 2022, 16(6): 1299-1312. [25] Becerra-Fajardo L, Tudela-Pi M, Ivorra A.Two-port networks to model galvanic coupling for intrabody communications and power transfer to implants[C]// 2018 IEEE Biomedical Circuits and Systems Con- ference (BioCAS), Cleveland, OH, USA, 2018: 1-4. [26] Aldaoud A, Redoute J M, Ganesan K, et al.Near-field wireless power transfer to stent-based biomedical implants[J]. IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 2018, 2(3): 193-200. [27] Sedehi R, Budgett D, Jiang Jincheng, et al.A wireless power method for deeply implanted biomedical devices via capacitively coupled conductive power transfer[J]. IEEE Transactions on Power Electronics, 2021, 36(2): 1870-1882. [28] 贾静, 柯丽, 杜强, 等. 胸腔生物阻抗检测对人体植入电子设备安全性研究[J]. 电工技术学报, 2024, 39(22): 6990-6997. Jia Jing, Ke Li, Du Qiang, et al.Safety evaluation of thoracic bio-electrical impedance technique[J]. Trans- actions of China Electrotechnical Society, 2024, 39(22): 6990-6997. [29] Gabriel S, Lau R W, Gabriel C.The dielectric properties of biological tissues: Ⅲ. Parametric models for the dielectric spectrum of tissues[J]. Physics in Medicine and Biology, 1996, 41(11): 2271-2293. [30] IEEE C95.1—2019. IEEE standard for safety levels with respect to human exposure to electric, magnetic, and electromagnetic fields, 0 Hz to 300 GHz[J]. IEEE Std C95.1—2019 (Revision of IEEE Std C95.1—2005/Incorporates IEEE Std C95.1—2019/Cor 1—2019), 2019: 1-312. [31] 赵军, 赵毅航, 武志军, 等. 电动汽车无线充电系统对心脏起搏器的电磁兼容与热效应影响[J]. 电工技术学报, 2022, 37(增刊1): 1-10. Zhao Jun, Zhao Yihang, Wu Zhijun, et al.The influence of electric vehicle wireless charging system on electromagnetic compatibility and thermal effect of cardiac pacemaker[J]. Transactions of China Electrotechnical Society, 2022, 37(S1): 1-10. [32] International Electrotechnical Commission (IEC)/ Institute of Electrical and Electronics Engineers (IEEE) 62704—1: 2017. Determining the Peak Spatial-Average Specific Ab-Sorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz to 6 GHz—Part 1: General Requi- rements for Using the Finite Difference Time-Domain (FDTD) Method for SAR Calculations[S]. 2017. [33] Hossain A N M S, Erfani R, Mohseni P, et al. On the non-idealities of a capacitive link for wireless power transfer to biomedical implants[J]. IEEE Transactions on Biomedical Circuits and Systems, 2021, 15(2): 314-325.