Quantitative Calculation Method of Transformer Oil-Paper Insulation Aging Parameters Based on Frequency Dielectric Spectrum Frequency Range Optimized Calculation
1. Key Laboratory of Engineering Dielectrics and Its Application Ministry of Education Harbin University of Science and Technology Harbin 150080 China; 2. State Key Laboratory Breeding Base of Dielectrics Engineering Harbin University of Science and Technology Harbin 150080 China; 3. State Grid Electric Power Research Institute of Jilin Electric Power Co. Ltd Changchun 130021 China
Abstract:Stable operation of transformers is an important guarantee for the safe operation of power grids. The aging of oil-paper insulation in transformer can be evaluated more accurately by frequency-domain dielectric spectroscopy. The current evaluation methods mostly focus on the evaluation of aging status of single oil-paper insulation. The aging state assessment of transformer equivalent model is less, and the evaluation software is extremely inaccurate. In order to further meet the practical engineering application, in this paper, a numerical method for calculating the aging state of transformer oil-paper insulation based on equivalent model of transformer is presented. The relevant validation was carried out by accelerated aging test. Firstly, the variable temperature dielectric spectroscopy curves of oil-immersed pressboard with different ageing were obtained under laboratory conditions. According to frequency-temperature translation, the activation energy of oil-immersed pressboard with different aging degrees was calculated. The quantitative characterization equation of the degree of polymerization and activation energy of oil-immersed pressboard was established. Secondly, the basic data of oil-immersed pressboard at different test temperatures and aging degrees were obtained by inverted frequency temperature translation method. Finally, the influence of the transformer equivalent model structure on the frequency range of the frequency domain dielectric loss factor was analyzed. By using the proposed frequency-range numerical iteration algorithm, when the goodness of fit between test curve and calculation curve is the best, the degree of polymerization, moisture content of oil-immersed pressboard and conductivity of transformer oil in transformer equivalent XY model can be obtained. Compared with the physical and chemical performance analysis results, the error is small. It can effectively reduce the time of insulation aging assessment of transformers in the field.
刘骥, 张明泽, 赵春明, 程炜超, 贾海峰, 朱博. 基于频域介电响应分频段优化计算的变压器油纸绝缘老化参数定量计算方法[J]. 电工技术学报, 2020, 35(9): 2020-2031.
Liu Ji, Zhang Mingze, Zhao Chunming, Cheng Weichao, Jia Haifeng, Zhu Bo. Quantitative Calculation Method of Transformer Oil-Paper Insulation Aging Parameters Based on Frequency Dielectric Spectrum Frequency Range Optimized Calculation. Transactions of China Electrotechnical Society, 2020, 35(9): 2020-2031.
[1] 杜林, 冉鹂蔓, 蔚超, 等. 基于扩展德拜模型的油纸绝缘受潮频域特征量研究[J]. 电工技术学报, 2018, 33(13): 3051-3058. Du Lin, Ran Liman, Wei Chao, et al.Study on frequency domain characteristics of moisture in oil- paper insulation based on extended debye model[J]. Tansactions of China Electrotechnical Society, 2018, 33(13): 3051-3058. [2] Gubanski S, Boss P, Csepes G, et al.Dielectric response methods for diagnostics of power trans- formers[J]. IEEE Electrical Insulation Magazine, 2003, 19(3): 12-18. [3] Paraskevas C, Vassiliou P, Dervos C.Temperature dependent dielectric spectroscopy in frequency domain of high-voltage transformer oils compared to physicochemical results[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2006, 13(3): 539-546. [4] Saha T K, Purkait P.Understanding the impacts of moisture and thermal ageing on transformer’s insulation by dielectric response and molecular weight measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008, 15(2): 568-582. [5] 廖瑞金, 刘捷丰, 吕彦东, 等. 变压器油纸绝缘含水量定量评估的频域介电特征参量研究[J]. 电工技术学报, 2015, 30(1): 204-211. Liao Ruijin, Liu Jiefeng, Lü Yandong, et al.Study on frequency domain dielectric characteristic parameters for quantitative evaluation of moisture content in transformer oil paper insulation[J]. Transactions of China Electrotechnical Society, 2015, 30(1): 204-211. [6] Liao Ruijin, Liu Jiefeng, Yang Lijun, et al.Quanti- tative analysis of insulation condition of oil-paper insulation based on frequency domain spectro- scopy[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2010, 22(1): 322-334. [7] 廖瑞金, 郝建, 杨丽君, 等. 变压器油纸绝缘频域介电谱特性的仿真与实验研究[J]. 中国电机工程学报, 2010, 30(22): 113-119. Liao Ruijin, Hao Jian, Yang Lijun, et al.Simulation and experimental study on frequency-domain dielectric spectroscopy of oil-paper insulation for trans- formers[J]. Proceedings of the CSEE, 2010, 30(22): 113-119. [8] 王世强, 魏建林, 张冠军, 等. 温度对油纸绝缘介电响应特性的影响[J]. 电工技术学报, 2012, 27(5): 50-55. Wang Shiqiang, Wei Jianlin, Zhang Guanjun, et al.Effect of temperature on dielectric response characte- ristics of oil impregnated pressboard[J]. Transactions of China Electrotechnical Society, 2012, 27(5): 50-55. [9] Wang Shiqiang, Zhang Guanjun, Wei Jianlin, et al.Investigation of dielectric response characteristics of thermal aged insulating pressboard in vacuum and oil-impregnated ambient[J]. IEEE Transactions on Magnetics, 2010, 17(6): 1853-1862. [10] 吴广宁, 崔运光, 段宗超, 等. 有机酸对变压器油纸绝缘进一步热老化的催化作用试验研究[J]. 高电压技术, 2015, 41(3): 832-839. Wu Guangning, Cui Yunguang, Duan Zongchao, et al.Experimental study on further thermal aging of transformer oil-paper insulation by organic acid catalysis[J]. High Voltage Engineering, 2015, 41(3): 832-839. [11] 李海燕, 何梦, 黄林, 等. 超高压变压器油中酸类物质的生成规律和变压器热老化状况分析[J]. 高电压技术, 2015, 41(6): 1959-1964. Li Haiyan, He Meng, Huang Lin, et al.Correlation between the generation of acidic products and the thermal aging of oil-paper insulation of the UHV transformer[J]. High Voltage Engineering, 2015, 41(6): 1959-1964. [12] 董明, 刘媛, 任明, 等. 油纸绝缘频域介电谱解释方法研究[J]. 中国电机工程学报, 2015, 35(4): 1002-1008. Dong Ming, Liu Yuan, Ren Ming, et al.Explanation study of frequency-domain dielectric spectroscopy for oil-paper insulation system[J]. Proceedings of the CSEE, 2015, 35(4): 1002-1008. [13] 董明, 刘媛, 任明, 等. 油纸绝缘频域介电谱特征参数提取及绝缘状态相关性研究[J]. 中国电机工程学报, 2015, 35(23): 6246-6253. Dong Ming, Liu Yuan, Ren Ming, et al.Study of characteristic parameter extraction and insulation condition correlation of frequencydomain dielectric spectroscopy for oil-paper insulation systems[J]. Proceedings of the CSEE, 2015, 35(23): 6246-6253. [14] 杨丽君, 齐超亮, 邓帮飞, 等. 采用修正Cole-Cole模型提取油纸绝缘频域介电谱的特征参量方法[J]. 高电压技术, 2013, 39(2): 310-317. Yang Lijun, Qi Chaoliang, Deng Bangfei, et al.Application of modified Cole-Cole model to extract characteristics of frequency dielectric spectroscopy of oil-paper insulation[J]. High Voltage Engineering, 2013, 39(2): 310-317. [15] 王东阳, 周利军, 朱少波, 等. 不同温度油隙频域介电谱的归算方法[J]. 中国电机工程学报, 2016, 36(23): 6583-6592. Wang Dongyang, Zhou Lijun, Zhu Shaobo, et al.Calculation method of dielectric spectrum in frequency domain of oil gap at different temperatures[J]. Proceedings of the CSEE, 2016, 36(23): 6583-6592. [16] Paweł Z, Tomasz N K, Konrad K, et al.Formation of water nanodrops in cellulose impregnated with insulating oil[J]. Cellulose, 2015, 22(1): 861-866. [17] Paweł Z, Tomasz N K, Konrad K.An analysis of AC conductivity in moist oil-impregnated insulation pressboard[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2015, 22(4): 2156-2164. [18] Koch M, Prevost T.Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2012, 19(6): 1908-1915. [19] 张明泽, 刘骥, 齐鹏帅, 等. 基于介电响应技术的变压器油纸绝缘含水率数值评估方法[J]. 电工技术学报, 2018, 33(18): 4397-4407. Zhang Mingze, Liu Ji, Qi Pengshuai, et al.Numerical evaluation method for moisture content of trans- former oil-paper insulation based on dielectric response technique[J]. Transactions of China Electro- technical Society 2018, 33(18): 4397-4407. [20] 廖瑞金, 刘捷丰, 杨丽君, 等. 电力变压器油纸绝缘状态评估的频域介电特征参量研究[J]. 电工技术学报, 2015, 30(6): 247-254. Liao Ruijin, Liu Jiefeng, Yang Lijun, et al.Investi- gation on frequency domain dielectric characteristics for condition assessment of transformer oil-paper insulation[J]. Transactions of China Electrotechnical Society, 2015, 30(6): 247-254. [21] Liao Ruijin, Liu Jiefeng, Yang Lijun, et al.Under- standing and analysis on frequency dielectric parameter for quantitative diagnosis of moisture content in paper-oil insulation system[J]. IET Electric Power Applications, 2015, 9(3): 213-222. [22] Lamkaouehi K, Ellison W J, Moreau J M.Water: a dielectric reference[J]. Journal of Molecular Liquids, 1996, 68(2): 171-279. [23] 张明泽, 刘骥, 吕佳璐, 等. 换油周期对变压器油纸绝缘老化性能影响规律研究[J]. 电工技术学报, 2019, 34(22): 4827-4838. Zhang Mingze, Liu Ji, Lü Jialu, et al.Research on aging influence of oil replacement cycle in trans- former oil-paper insulation[J]. Transactions of China Electrotechnical Society, 2019, 34(22): 4827-4838.