DC Breakdown Characteristics of Flowing Transformer Oil Contaminated by Metallic Particles
Yao Yuhang1, Tao Xiantao2, Yu Mengyue1, Pan Cheng1, Tang Ju1
1. State Key Laboratory of Power Grid Environmental Protection School of Electrical Engineering and Automation Wuhan University Wuhan 430072 China; 2. China Electric Power Research Institute Wuhan 430074 China
Abstract:The presence of free metallic particles in power transformer oil poses a significant threat to its insulation due to their conductivity and their ability to distort the electric field. With the increasing rated voltage levels, the negative effects resulting from particle motion and accumulation have gained considerable attention. However, previous investigations have primarily focused on static liquid conditions, overlooking the fact that transformer oil in operational equipment keeps consistentlyflowing due to circulation systems and temperature gradients. The motion behaviors of metallic particles are altered by the flowing of oil, consequently affecting the breakdown characteristics of contaminated oil. The breakdown characteristics and mechanisms of transformer oil containing metallic particles under flowing conditions are not well understood. Therefore, this study aims to address this knowledge gap. Before the test, 6.2 g of metallic particles with a diameter of ~150 μmare injected into the circulating system of transformer oil, with a particle concentration of 3 500 pieces/100 mL. The flow velocity of the transformer oil is controlled by adjusting the oil pump speed. Experimental tests on the breakdown characteristics of flowing transformer oil are conducted, using a custom-built experimental platform. And two types of breakdown tests, without preload and with preload, are performed. During the experiments, a synchronized data acquisition system comprising a high-speed camera and oscilloscope is employed to record the distribution of metallic particles before breakdown and the discharge signals at the moment of breakdown. The results indicate that the presence of metallic particles significantly reduces the insulation withstand capability of flowing transformer oil. Compared to pure transformer oil, the DC breakdown voltage of oil decreases by more than 30%. Furthermore, the characteristic breakdown voltage of contaminated oil initially exhibits a rapid increase with flow velocity and then gradually stabilizes. When the oil flow velocity is below 0.25 m/s, the breakdown voltage after preload is lower than that without preload. However, as the flow velocity continues to increase, the two values gradually converge. Finally, the influence mechanism of oil flow velocity on the breakdown characteristics of transformer oil is discussed in conjunction with the variation in particle distribution in the oil gap. The images captured before breakdown indicate that the breakdown of transformer oil containing metallic particles is primarily caused by individual metallic particles in close proximity to the energized electrode surface. When these particles come into contact with the electrode, it results in severe distortion of the local electric field, leading to partial discharge (PD). Following discharge, the metallic particles can be regarded as metallic protrusions on the high-voltage electrode, further contributing to gap breakdown. The oil flow velocity affects the breakdown characteristics by modifying the distribution of metallic particles during the pre-breakdown stage. As the flow velocity increases, the number of particles in the oil gap gradually decreases, reducing the possibility of breakdown. After preload for 20 minutes at 10 kV, metallic particles tend to accumulate in stagnant and low-velocityflow. Thereby, the particle concentrationprior to breakdownincreases and the electric field in the contaminated oilis distorted, resulting in a further reduction of the breakdown voltage.
姚雨杭, 陶霰韬, 于梦悦, 潘成, 唐炬. 含自由金属微粒流动变压器油的直流击穿特性[J]. 电工技术学报, 2023, 38(zk1): 157-167.
Yao Yuhang, Tao Xiantao, Yu Mengyue, Pan Cheng, Tang Ju. DC Breakdown Characteristics of Flowing Transformer Oil Contaminated by Metallic Particles. Transactions of China Electrotechnical Society, 2023, 38(zk1): 157-167.
[1] 徐政. 交直流电力系统动态行为分析: 机械工业出版社高水平著作出版基金资助项目[M]. 北京: 机械工业出版社, 2004. [2] 张永泽, 唐炬, 潘成, 等. 油流速度对含气泡变压器油击穿特性的影响[J]. 电工技术学报, 2022, 37(2): 479-487. Zhang Yongze, Tang Ju, Pan Cheng, et al.Impact of velocity on breakdown characteristics of transformer oil containing bubbles[J]. Transactions of China Electrotechnical Society, 2022, 37(2): 479-487. [3] 张文亮, 于永清, 李光范, 等. 特高压直流技术研究[J]. 中国电机工程学报, 2007, 27(22): 1-7. Zhang Wenliang, Yu Yongqing, Li Guangfan, et al.Researches on UHVDC technology[J]. Proceedings of the CSEE, 2007, 27(22): 1-7. [4] 董新洲, 汤涌, 卜广全, 等. 大型交直流混联电网安全运行面临的问题与挑战[J]. 中国电机工程学报, 2019, 39(11): 3107-3118. Dong Xinzhou, Tang Yong, Bu Guangquan, et al.Confronting problem and challenge of large scale AC-DC hybrid power grid operation[J]. Proceedings of the CSEE, 2019, 39(11): 3107-3118. [5] Mahmud S, Chen G, Golosnoy I O, et al.Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oil[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2015, 22(1): 152-160. [6] Mahmud S, Chen G, Golosnoy I O, et al.Experimental studies of influence of different electrodes on bridging in contaminated transformer oil[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2015, 22(5): 2433-2441. [7] L’vov S Y, Komarov V B, Bondareva V N, et al.Contamination of the transformer oil of power transformers and shunting reactors by metal-containing colloidal particles[J]. Power Technology and Engineering, 2011, 45(1): 76-81. [8] Tang Ju, Ma Shouxiao, Zhang Mingjun, et al.Influence of microbubbles motion state on partial discharge in transformer oil[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2015, 22(5): 2646-2652. [9] 姚雨杭, 潘成, 唐炬, 等. 交直流复合电压下流动变压器油中金属微粒运动规律和局部放电特性研究[J]. 电工技术学报, 2021, 36(15): 3101-3112. Yao Yuhang, Pan Cheng, Tang Ju, et al.Motion behaviors and partial discharge characteristics of metallic particles in moving transformer oil under AC/DC composite voltage[J]. Transactions of China Electrotechnical Society, 2021, 36(15): 3101-3112. [10] 于敏潮, 肖福明, 胡秉海, 等. 变压器油中颗粒度对变压器绝缘强度的影响[J]. 变压器, 2000, 37(12): 26-30. Yu Minchao, Xiao Fuming, Hu Binghai, et al.Influence of graininess in transformer oil on dielectrical strength of transformer[J]. Transformer, 2000, 37(12): 26-30. [11] Wang Youyuan, Li Yuanlong, Wei Chao, et al.Copper particle effect on the breakdown strength of insulating oil at combined AC and DC voltage[J]. Journal of Electrical Engineering and Technology, 2017, 12(2): 865-873. [12] Li X.Practical technology of transformer oil pump[M]. Beijing: China Electric Power Press, 2010. [13] Carraz F, Rain P, Tobazeon R.Particle-initiated breakdown in a quasi-uniform field in transformer oil[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 1995, 2(6): 1052-1063. [14] Wang X, Wang Z D, Noakhes J.Motion of conductive particles and the effect on AC breakdown strengths of esters[C]//IEEE International Conference on Dielectric Liquids, 2011: 6015453. [15] Zhang Jing, Wang Feipeng, Li Jian, et al.Influence of copper particles on breakdown voltage and frequency-dependent dielectric property of vegetable insulating oil[J]. Energies, 2017, 10(7): 938. [16] 李原龙. 固体颗粒在绝缘油中的运动特性及对绝缘油击穿强度的影响[D]. 重庆: 重庆大学, 2017. [17] 陈彬, 韩超, 刘阁. 颗粒污染物对变压器油击穿电压的影响[J]. 高电压技术, 2018, 44(12): 3903-3909. Chen Bin, Han Chao, Liu Ge.Effect of particulate contamination on breakdown voltage of transformer oil[J]. High Voltage Engineering, 2018, 44(12): 3903-3909. [18] Pan Cheng, Tang Ju, Tao Xiantao, et al.Partial discharge and breakdown characteristics of moving transformer oil contaminated by metallic particles[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2018, 25(5): 1774-1784. [19] 程林, 李兴兴, 唐炬, 等等. 不同温度下含金属微粒的流动液体绝缘介质放电形成过程与机理分析[J]. 高电压技术, 2018, 44(9): 2917-2925. Cheng Lin, Li Xingxing, Tang Ju, et al.discharge process and its mechanism analysis in flowing liquid dielectric containing metal particles at different temperatures[J]. High Voltage Enginering, 2018, 44(9): 2917-2925. [20] Dan Min, Hao Jian, Liao Ruijin, et al.Accumulation behaviors of different particles and effects on the breakdown properties of mineral oil under DC voltage[J]. Energies, 2019, 12(12): 2301. [21] 张永泽, 唐炬, 潘成, 等. 温度对流动变压器油中悬移气泡局部放电特性的影响与作用机制[J]. 电工技术学报, 2020, 35(6):1357-1367. Zhang Yongze, Tang Ju, Pan Cheng, et al.Effects of temperature on partial discharge characteristics induced by suspended bubbles in flowing transformer oil and the mechanism[J]. Transactions of China Electrotechnical Society, 2020, 35(6):1357-1367. [22] Insulating liquids - Determination of the breakdown voltage at power frequency - Test method:DS/EN 60156[S]. DS, 1995. [23] 王奕玲. 基于COMSOL的大型油浸式变压器绕组温度场数值分析[D]. 天津: 河北工业大学, 2019. [24] CIGRE Working Group 17 of Study Committee 12, Effect of particles on transformer dielectric strength[R]. Group 17 of Study Committee 12, Effect of particles on transformer dielectric strength[R]. Paris: CIGRE, 2000. [25] Cleanliness requirements of parts used in hydraulic Systems: NAS1638[S]. AIA/NAS, 2011. [26] 龙光. ODFS-334000/500自耦变压器高场强区域的电场计算[D]. 北京: 华北电力大学, 2013. [27] 夏苏怡, 潘成, 姚雨杭, 等. 稍不均匀直流电场下静止与流动变压器油中金属微粒聚集特性[J]. 高电压技术, 2023, 49(4): 1693-1702. Xia Suyi, Pan Cheng, Yao Yuhang, et al.Accumulation characteristics of metal particles in static and flowing transformer oil under slightly nonuniform DC field[J]. High Voltage Engineering, 2023, 49(4): 1693-1702. [28] Yao Yuhang, Xia Suyi, Tang Ju, et al.Charging characteristic of free metallic particles in transformer oil when the electrodes covered with insulation paper[C]//2021 IEEE 4th International Electrical and Energy Conference (CIEEC), Wuhan, China, 2021: 1-5. [29] Sun Anbang, Huo Chao, Zhuang Jie.Formation mechanism of streamer discharges in liquids: a review[J]. High Voltage, 2016, 1(2): 74-80.