A High Accuracy Phasor Estimation Algorithm for Phasor Measurement Units Calibrator
Xu Sudi1, Liu Hao1, Bi Tianshu1, Qian Cheng1, Zhang Feng2
1. State Key Lab of Alternate Electric Power System with Renewable Energy Sources North China Electric Power University Beijing 102206 China; 2. State Grid Xinjiang Electric Power Company Urumqi 830063 China
Abstract:The testing and calibration of phasor measurement units (PMUs) are fundamental for their deployments and operation in power systems. Therefore, how to offer references with enough accuracy for PMU static and dynamic tests is critical. In this paper, a high accuracy phasor estimation algorithm for PMU calibrator is proposed. The universal phasor fitting models are built; the non-linear fitting-based phasor calculation algorithm is proposed according to the built optimization model minimizing the sum of squares of residuals; parameter initial points and bound constraints setting methods are proposed to solve multiple solutions resulting from nonlinear and nonconvex phasor fitting models; white noise restrain methods are presented to further improve the measurement accuracy. Furthermore, the PMU calibrator is developed. The results of both simulation and experimental test show that the accuracy of the PMU calibrator can meet requirements for calibration. The developed PMU calibrator can be used to test PMUs in the laboratory without high accuracy generator.
许苏迪, 刘灏, 毕天姝, 钱程, 张锋. 一种适用于同步相量测量装置校准器的高精度相量测量方法[J]. 电工技术学报, 2020, 35(2): 372-382.
Xu Sudi, Liu Hao, Bi Tianshu, Qian Cheng, Zhang Feng. A High Accuracy Phasor Estimation Algorithm for Phasor Measurement Units Calibrator. Transactions of China Electrotechnical Society, 2020, 35(2): 372-382.
[1] 罗深增, 李银红, 石东源. 广域测量系统可观性概率评估及其在PMU优化配置中的应用[J]. 电工技术学报, 2018, 33(8): 1844-1853. Luo Shenzeng, Li Yinhong, Shi Dongyuan.Wide area monitoring system observability probabilistic evaluation and it’s application in optimal PMU placement[J]. Transactions of China Electrotechnical Society, 2018, 33(8): 1844-1853. [2] 邵雅宁, 唐飞, 刘涤尘, 等. 一种适用于WAMS量测数据的系统暂态功角稳定评估方法[J]. 电力系统保护与控制, 2015, 43(6): 33-39. Shao Yaning, Tang Fei, Liu Dichen, et al.An approach of transient angle stability assessment in power system for WAMS measured data[J]. Power System Protection and Control, 2015, 43(6): 33-39. [3] 王臻, 李承, 林志芳, 等. 考虑高斯有色噪声的FOMC-HTLS-Adaline算法在低频振荡模式辨识中的研究[J]. 电工技术学报, 2017, 32(6): 21-30. Wang Zhen, Li Cheng, Lin Zhifang, et al.Research on low frequency oscillation mode identification based on FOMC-HTLS-Adaline algorithm considering colored gaussian noises[J]. Transactions of China Electrotechnical Society, 2017, 32(6): 21-30. [4] 姜涛, 贾宏杰, 李国庆, 等. 基于广域量测信息相关性的电力系统同调辨识[J]. 电工技术学报, 2017, 32(1): 1-11. Jiang Tao, Jia Hongjie, Li Guoqing, et al.Cross- correlation coefficient-based coherency identification in Bulk power system using wide-area measure- ments[J]. Transactions of China Electrotechnical Society, 2017, 32(1): 1-11. [5] Q/GDW 1131-2014 电力系统实时动态监测系统技术规范[S]. 北京: 国家电网公司, 2015. [6] IEEE Std.C37.118.1-2011. IEEE standard for synchro-phasor measurements for power systems[S]. 2011-10. [7] IEEE standard for synchro-phasor measurements for powersystems-amendment 1: modification of selected performance requirements[S]. IEEE Std C37.118.1a- 2014, 2014-04. [8] Pogliano U, Braun J P, Voljč B, et al.Software platform for PMU algorithm testing[J]. IEEE Transactions on Instrumentation & Measurement, 2013, 62(6): 1400-1406. [9] Grando F L, Denardin G W, Moreto M.Test platform for analysis and development of phasor measurement units (PMU)[C]//IEEE International Conference on Industry Applications, Curitiba, 2017: 1-6. [10] 毕天姝, 刘灏, 杨奇逊. PMU算法动态性能及其测试系统[J]. 电力系统自动化, 2014, 38(1): 62-67. Bi Tianshu, Liu Hao, Yang Qixun.Dynamic performance of PMU algorithm and its testing system[J]. Automation of Electric Power Systems, 2014, 38(1): 62-67. [11] Caldwell D.ANSI/NCSL Z540.3: 2006: Require- ments for the calibration of measuring and test equipment[S]. 2006. [12] Tang Y, Stenbakken G N.Calibration of phasor measurement unit at NIST[J]. IEEE Transactions on Instrumentation & Measurement, 2013, 62(6): 1417-1422. [13] Kilter J, Palu I, Almas M S, et al.Experiences with dynamic PMU compliance testing using standard relay testing equipment[C]//Innovative Smart Grid Technologies Conference, Washington, DC, 2015: 103-110. [14] Trinchera B, Serazio D, Pogliano U.Asynchronous phase comparator for characterization of devices for PMUs calibrator[J]. IEEE Transactions on Instru- mentation & Measurement, 2017, 66(6): 1139-1145. [15] 金涛, 陈毅阳, 段小华, 等. 基于改进DFT的电力系统同步相量测量算法研究[J]. 电工技术学报, 2017, 32(17): 1-10. Jin Tao, Chen Yiyang, Duan Xiaohua, et al.Research on synchronous phasor measurement algorithm of power system based on improved DFT[J]. Transactions of China Electrotechnical Society, 2017, 32(17): 1-10. [16] Xia Tao, Liu Yilu.Single-phase phase angle measurements in electric power systems[J]. IEEE Transactions on Power Systems, 2010, 25(2): 844-852. [17] Romano P, Paolone M.Enhanced interpolated-DFT for synchrophasor estimation in FPGAs: theory, implementation, and validation of a PMU proto- type[J]. IEEE Transactions on Instrumentation & Measurement, 2014, 63(12): 2824-2836. [18] 刘洁波, 黄纯, 江亚群, 等. 基于强跟踪泰勒-卡尔曼滤波器的动态相量估计算法[J]. 电工技术学报, 2018, 33(2): 433-441. Liu Jiebo, Huang Chun, Liu Yaqun, et al.Dynamic phasor estimator based on strong tracking Taylor- Kalman filter[J]. Transactions of China Electro- technical Society, 2018, 33(2): 433-441. [19] Belega D, Fontanelli D, Petri D.Dynamic phasor and frequency measurements by an improved Taylor weighted least squares algorithm[J]. IEEE Transa- ctions on Instrumentation & Measurement, 2015, 64(8): 2165-2178. [20] 符玲, 韩文朕, 麦瑞坤, 等. 利用频域信息滤除衰减直流的同步相量测量算法[J]. 中国电机工程学报, 2016, 36(18): 4923-4929. Fu Ling, Han Wenzheng, Mai Ruikun, et al.Phasor estimator based on frequency-domain information considering decaying DC components[J]. Pro- ceedings of the CSEE, 2016, 36(18): 4923-4929. [21] Horio M, Morimoto J, Tabuchi T.A method for nonlinear least squares problem[J]. Technical Bulletin of Tokushima Bunri University, 2008, 75: 81-95. [22] Zhan Lingwei, Liu Yong, Culliss J, et al.Dynamic single-phase synchronized phase and frequency estimation at the distribution level[J]. IEEE Transa- ctions on Smart Grid, 2015, 6(4): 2013-2022.