电工技术学报  2017, Vol. 32 Issue (19): 118-124    DOI: 10.19595/j.cnki.1000-6753.tces.161082
电机与电器 |
基于滑动离散傅里叶变换的串联直流电弧故障识别
王尧1,李阳2,葛磊蛟3,牛峰1,4,李奎1
1. 省部共建电工装备可靠性与智能化国家重点实验室河北工业大学 天津 300130;
2. 天津工业大学电气与自动化学院 天津 300387;
3. 天津大学电气自动化与信息工程学院 天津 300072;
4. 浙江大学电气工程学院 杭州 310027
A Series DC Arcing Fault Recognition Method Based on Sliding Discrete Fourier Transform
Wang Yao1, Li Yang2, Ge Leijiao3, Niu Feng1, 4, Li Kui1
1. State Key Laboratory of Reliability and Intelligence of Electrical Equipment Hebei University of Technology Tianjin 300130 China;
2. School of Electrical Engineering and Automation Tianjin Polytechnic University Tianjin 300387 China;
3. School of Electrical and Information Engineering Tianjin University Tianjin 300072 China;
4. School of Electrical Engineering Zhejiang University Hangzhou 310027 China
全文: PDF (3141 KB)  
输出: BibTeX | EndNote (RIS)      
摘要 在直流供电系统中,串联直流电弧故障因难于被检测而成为威胁系统安全运行的最主要因素。针对现有故障电弧识别方法运算较为复杂、实时性相对较差的不足,提出一种基于滑动离散傅里叶变换(DFT)的串联直流电弧故障识别方法。时域与频域分析表明,燃弧起始阶段是直流电弧故障识别的最佳时期,根据该阶段电弧电流的频谱特征确定滑动DFT分析频率点为40 kHz、80 kHz和100 kHz。综合考虑算法分辨率与实时性要求,采用200 μs时间窗口对电弧电流进行滑动DFT分析,并用200 μs时间窗口进行滑动平均降噪处理。结果表明,发生电弧故障前后滑动DFT频谱在三个特征频率点均有明显变化,验证了滑动DFT算法用于串联直流电弧故障识别的可行性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
王尧
李阳
葛磊蛟
牛峰
李奎
关键词 串联直流电弧电弧故障故障识别滑动离散傅里叶变换    
Abstract:Series DC arcing fault pose an extreme safety risk in DC power system because it is difficult to be detected. A sliding discrete fourier transform (DFT) based arcing fault recognition method is proposed to meet the requirement of real-time in detection and reduction in algorithm complexity. The arcing initiation stage is the best moment for fault detection based on analysis both in time domain and in frequency domain. Accordingly, three characteristic frequencies, 40 kHz, 80 kHz and 100 kHz, are selected for the point by point sliding DFT calculation. Moreover, a time-window of 200μs is used to implement the algorithm for simplicity and accuracy. Finally, it is concluded that all the three spectrums increase significantly during the arcing fault. And the sliding DFT algorithm can be applied for series DC arcing fault recognition.
Key wordsSeries DC arcing    arcing fault    fault detection    sliding discrete fourier transform   
收稿日期: 2016-07-13      出版日期: 2017-10-25
PACS: TM501  
作者简介: 王尧男,1981年生,博士,讲师,研究方向为智能电器。E-mail:wangyao@hebut.edu.cn;李奎男,1965年生,教授,博士生导师,研究方向为智能电器、电器可靠性与检测技术。Email:likui@hebut.edu.cn(通信作者)
引用本文:   
王尧,李阳,葛磊蛟,牛峰,李奎. 基于滑动离散傅里叶变换的串联直流电弧故障识别[J]. 电工技术学报, 2017, 32(19): 118-124. Wang Yao, Li Yang, Ge Leijiao, Niu Feng, Li Kui. A Series DC Arcing Fault Recognition Method Based on Sliding Discrete Fourier Transform. Transactions of China Electrotechnical Society, 2017, 32(19): 118-124.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/10.19595/j.cnki.1000-6753.tces.161082          https://dgjsxb.ces-transaction.com/CN/Y2017/V32/I19/118