1. School of Electrical Engineering Wuhan University Wuhan 430072 China; 2. Beijing Electric Power Research Institute Beijing 100075 China; 3. Southwest Branch of State Grid Corporation Chengdu 610041 China
Abstract:This paper establishes a simulation model of the transformer and studies in case of partial discharge power supply fixed, the sound pressure propagation in space, sound pressure amplitude variation in the spread process, the influence of the position of the partial discharge on signal propagation characteristics and acoustic attenuation of propagation in the core windings and transformer oil. Simulation results show partial discharge occurs within 1ms after the explosion, and the spatial distribution of the sound pressure inside the transformer changes rapidly, but there is no significant changes after 1ms. The change of sound pressure in the core and winding of the transformer is larger than that in the oil. Partial discharge explosion spreads to the surrounding medium in the form of wave front with spherical wave. The closer the position of the partial discharge power source is, the bigger of the received signal amplitude is. When acoustic wave propagates in the core, winding and transformer oil, the sound pressure amplitude possesses different attenuation in three directions due to the different propagation path and the increasing of the propagation distance. Experiments show the validity of the simulation results. And the analysis can provide the basis for the detection of partial discharge in transformer.
[1] 刘君华, 徐敏骅, 黄成军, 等. 局部放电电磁波在GIS中的衰减特性[J]. 电工技术学报, 2010, 25(8): 52-58. Liu Junhua, Xu Minhua, Huang Chengjun, et al. Investigation on the attenuation characteristics of electromagnetic waves in GIS[J]. Transactions of China Electrotechnical Society, 2010, 25(8): 52-58. [2] 叶海峰, 钱勇, 刘宗杰, 等. 一种新型的放电源空间定位用特高频传感器[J]. 电工技术学报, 2015, 30(8): 333-340. Ye Haifeng, Qian Yong, Liu Zongjie, et al. A new UHF sensor for spatial location of partial discharge sources[J]. Transactions of China Electrotechnical Society, 2015, 30(8): 333-340. [3] Li Yanqing, Chen Zhiye, Lu Fangcheng. Patern recognition of transformer partial discharge based on acoustic method[J]. Proceedings of the CSEE, 2003, 23(2): 108-111. [4] 辛晓虎, 李继胜, 纪海英, 等. 用于变压器中局部放电定位的十字形超声阵列传感器研究[J]. 中国电机工程学报, 2013, 33(21): 154-162. Xin Xiaohu, Li Jisheng, Ji Haiying, et al. Study of cross-shaped ultrasonic array senor applied to partial discharge location in transformers[J]. Proceedings of the CSEE, 2013, 33(21): 154-162. [5] 程述一, 律方成, 谢庆, 等. 基于暂态对地电压和超声阵列信号的变压器局放定位方法[J]. 电工技术学报, 2012, 27(4): 255-262. Cheng Shuyi, Lü Fangcheng, Xie Qing, et al. Study of partial discharge locating method in transformer based on transient earth voltage and ultrasonic array signals[J]. Transactions of China Electrotechnical Society, 2012, 27(4): 255-262. [6] Akbari A, Werle P, Borsi H, et al. Transfer function based partial discharge localization in power transformers: a feasibility study[J]. IEEE Electrical Insulation Magazine, 2002, 18(5): 22-32. [7] 唐炬, 吴建蓉, 卓然, 等. 针-板局部放电VHF信号与放电量之间的等量关系[J]. 高电压技术, 2010, 36(5): 1083-1089. Tang Ju, Wu Jianrong, Zhuo Ran, et al. Relationship between VHF signals and discharge magnitude of partial discharge from needle plate electrode[J]. High Voltage Engineering, 2010, 36(5): 1083-1089. [8] 郑文栋, 杨宁, 钱勇, 等. 多传感器联合检测技术在XLPE电缆附件局部放电定位中的试验研究[J]. 电力系统保护与控制, 2011, 39(20): 84-88. Zheng Wendong, Yang Ning, Qian Yong, et al. Experimental research on partial discharge locali- zation in XLPE cable accessories using multi sensor joint detection technology[J]. Power System Pro- tection and Control, 2011, 39(20): 84-88. [9] 张雄清, 刘黎, 金海龙. 35kV开关柜局放检测异常分析及处理[J]. 电气技术, 2013, 14(6): 58-60. Zhang Xiongqing, Liu Li, Jin Hailong. The analysis and processing on the aberrant PD of 35kV switch- gear[J]. Electrical Engineering, 2013, 14(6): 58-60. [10] TADean, Liu Zhenqing. Relationship between disper- sive characteristics of ultrasonic guided waves and inner-radius=thickness ratio of pipes[J]. Journal of Fudan University, 2003(1): 7-13. [11] Yang Lingjian, Zhang Lingling, Gao Songwei. Guided wave propagation characteristics in the steel tube[J]. Non-Destructive Testing, 2011, 186(1): 9-12. [12] Taizawa H, Burani G F. Analysis and location of partial discharges in power transformers by means of electrical methods[C]//IEEE 16th International Conference and Exhibition on Electricity Distribution, Part 1: Contributions, Amsterdam 2001, 1: 482. [13] Lu Y, Tan X, Hu X. PD detection and localization by acoustic measurements in an oil-filled transformer science[C]//IEE Proceedings of Science, Measure- ment and Technology, 2000, 147(2): 81-85.