Preparation of Oil-Paper Insulation Samples with Moisture Equilibrium and Frequency Domain Characteristic Parameters Extraction for Moisture Assessment
Gao Jun1, Liao Ruijin1, Wang Youyuan1, Lü Yandong2, Yang Lijun1, Liu Jiefeng1, Wang Ke3
1. State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing 400044 China; 2. Alstom Grid Technology Center Co., Ltd. Shanghai 201114 China; 3. China Electric Power Research Institute Beijing 100192 China
Abstract:In order to promote the applicaton of the frequency-domain dielectric spectroscopy (FDS) to the nondestructive diagnosis of oil-paper insulation states of transformer, it is necessary to establish a reliable dielectric response database of oil-paper insulation with different equilibrium moisture contents in the laboratory. In this paper, a new preparation method for oil-paper insulation samples with different equilibrium moisture contents is proposed and the transient and stable frequency domain dielectric responses of oil-paper insulation during the migration process of moisture between oil and pressboard are deeply investigated. In the meanwhile, the quantitative relationships between moisture and characteristic parameters extracted from frequency domain dielectric properties are established. Finally, the actual moisture content of pressboards is measured by the Karl Fischer moisture meter to verify the validity of the proposed preparation method. Results show that in the migration process of moisture between oil and pressboard, the real part C′ of the complex capacitance increase obviously within 10-3~100 Hz, while the imaginary part C″ of the complex capacitance and the dielectric loss parameter tanδ present a clear tendency towards the high frequency region. The clear functional relationships between tanδ, C′, C″ and the moisture content in the pressboard are respectively observed in their characteristic frequency points(f=10-3Hz, 10-2Hz, 10-1Hz, 100Hz). The sample preparation method proposed in this paper can be used to accurately manufacture the pressboards with expected equilibrium moisture contents.
高竣, 廖瑞金, 王有元, 吕彦冬, 杨丽君, 刘捷丰, 汪可. 油纸绝缘水分平衡样品的制备及水分评估频域特征量提取[J]. 电工技术学报, 2015, 30(18): 196-202.
Gao Jun, Liao Ruijin, Wang Youyuan, Lü Yandong, Yang Lijun, Liu Jiefeng, Wang Ke. Preparation of Oil-Paper Insulation Samples with Moisture Equilibrium and Frequency Domain Characteristic Parameters Extraction for Moisture Assessment. Transactions of China Electrotechnical Society, 2015, 30(18): 196-202.
[1] Lundgaard L E, Hansen W, Linhjell D, et al. Aging of oil-impregnated paper in power transformer[J]. IEEE Transactions on Power Delivery, 2004, 19(1): 230- 239. [2] Emsley A M, Xiao X, Heywood R J, et al. Degrada- tion of cellulosic insulation in power transformers. Part 3: effects of oxygen and water in ageing in oil[J]. IEE Proceedings-Science, Measurement and Technology, 2000, 147(3): 115-119. [3] 王伟, 马志青, 李成榕, 等. 纤维素老化油纸绝缘水分平衡的影响[J]. 中国电机工程学报, 2012, 32(31): 100-104. Wang Wei, Ma Zhiqing, Li Chengrong, et al. Impact of cellulose aging on moisture equilibrium of oil- pressboard insulation[J]. Proceedings of the CSEE, 2012, 32(31): 100-104. [4] 周利军, 汤浩, 张血琴, 等. 油纸绝缘微水扩散的暂态分布模型[J]. 中国电机工程学报, 2008, 28(7): 134-140. Zhou Lijun, Tang Hao, Zhang Xueqin, et al. Disequili- brium moisture partition in oil-paper insulation[J]. Proceedings of the CSEE, 2008, 28(7): 134-140. [5] Oommen T. Moisture equilibrium charts for trans- former insulation dying practice[J]. IEEE Transactions on Power Apparatus System, 1984, 103(10): 3063- 3067. [6] Du Y, Zahn M, Lesieutre B C, et al. Moisture equili- brium in transformer paper-oil systems[J]. IEEE Electrical Insulation Magazine, 1999, 15(1): 11-20. [7] Maik Koch, Michael Kruger, Stefan Tenbohlen. Comparing various moisture determination methods for power transformers[C]. Cigré 6th Southern Africa Regional Conference, Somerset West, South Africa, 2009: 1-6. [8] Ekanayake C, Gubanski S M, Graczkowski A, et al. Frequency response of oil impregnated pressboard and paper samples for estimating moisture in transformer insulation[J]. IEEE Transactions on Power Delivery, 2006, 21(3): 1309-1317. [9] Blennow J, Gubanski S M. Field experiences with measurements of dielectric response in frequency domain for power transformer diagnostics[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2006, 21(2): 681-688. [10] Gubanski S M, Boss P, Csepes G, et al. Dielectric response methods for diagnostics of power trans- formers[J]. IEEE Electrical Insulation Magazine, 2003, 19(3): 12-18. [11] Koch M, Prevost T. Analysis of dielectric response measurements for condition assessment of oil paper transformer insulation[J]. IEEE Transactions on Dielec- trics and Electrical Insulation, 2012, 19(6): 1908-1915. [12] 魏建林, 王世强, 彭华东, 等. 变压器油纸绝缘的介电响应特性研究——加速热老化的介电谱[J]. 电工技术学报, 2012, 27(5): 56-62. Wei Jianlin, Wang Shiqiang, Peng Huadong, et al. Investigation of dielectric response characteristics of transformer oil-paper insulation—dielectric spectro- scopy of acceleratedly thermal aging[J]. Transactions of China Electrotechnical Society, 2012, 27(5): 56-62. [13] 廖瑞金, 郝建, 杨丽君, 等. 变压器油纸绝缘频域介电特征量与绝缘老化状态的关系[J]. 电工技术学报, 2012, 27(5): 43-49. Liao Ruijin, Hao Jian, Yang Lijun, et al. Relationship between frequency domain dielectric characteristic quantity and aging status of transformer oil-paper insulation[J]. Transactions of China Electrotechnical Society, 2012, 27(5): 43-49. [14] Saha T K. Review of modern diagnostic techniques for assessing insulation condition in aged transformers [J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2003, 10(5): 903-917. [15] Xu S, Middleton R, Fetherston F, et al. A comparison of return voltage measurement and frequency domain spectroscopy test on high voltage insulation[C]. Procee- dings of the IEEE 7th International Conference on Properties and Applications of Dielectric Materials, Nagoya, Japan, 2003: 351-355. [16] Saha T K, Purkait P. Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformers[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2004, 11(1): 144-154. [17] Csépes G, Hámos I, Brooks R, et al. Practical founda- tions of the RVM (recovery voltage method for oil/paper insulation diagnosis)[C]. 1998 IEEE Annual Report Conference on Electrical Insulation and Dielectric Phenomena, Atlanta, America, 1998: 345-355. [18] Linhjell D, Lundgaard L. Dielectric response of mineral oil impregnated cellulose and the impact of aging[J]. IEEE Transactions on Dielectrics and Electrical Insula- tion, 2007, 14(1): 156-169. [19] Zaengl W S. Dielectric spectroscopy in time and frequency domain for HV power equipment—part I: theoretical considerations[J]. IEEE Electrical Insulation Magazine, 2003, 19(5): 5-19. [20] Saha T K, Purkait P. Understanding the impacts of moisture and thermal ageing on transformer’s insulation by dielectric response and molecular weight measure- ments[J]. IEEE Transactions on Dielectrics and Elec- trical Insulation, 2008, 15(2): 568-581. [21] 王世强, 魏建林, 张冠军, 等. 温度对油纸绝缘介电响应特性的影响[J]. 电工技术学报, 2012, 27(5): 50-55. Wang Shiqiang, Wei Jianlin, Zhang Guanjun, et al. Effect of temperature on dielectric response characteris- tics of oil impregnated pressboard[J]. Transactions of China Electrotechnical Society, 2012, 27(5): 50-55. [22] Saha T K, Purkait P. Investigations of temperature effects on the dielectric response measurements of transformer oil paper insulation system[J]. IEEE Trans- actions on Power Delivery, 2008, 23(1): 252-260.