Abstract:The subsynchronous oscillation has been a dynamic stability problem that threatens the safe and stable operation of power systems, and serious subsynchronous oscillation events have occurred frequently in recent years around the world. Therefore, it is important to promptly extracting the oscillation components and precisely remove the oscillation source by monitoring the wide-frequency measurement data online. Most of conventional subsynchronous component extraction methods, however, have sluggish calculation times and low calculation accuracy, making it challenging to meet the oscillation monitoring demands of a wide-frequency measurement system. To address these issues, this paper suggests a method of calculating instantaneous power using the voltage and current from the wide-frequency measurement system, realizing the extraction of the frequency of the subsynchronous oscillation and the identification of the oscillation source. Based on the instantaneous power from the measured data, the analytical formulas for the multimodal subsynchronous power of a doubly-fed induction generator grid-connected system were derived in this article. The major components of the subsynchronous power were extracted in the three-phase symmetric and asymmetric situations. Afterwards, using the features of the alternating power component in the main component of subsynchronous power, it was suggested to develop a frequency extraction method based on the whole-cycle instantaneous power difference. This method is faster and more accurate than the traditional method, avoiding the picket fence effect and spectrum leakage issues. Additionally, a method of the identification for subsynchronous oscillation source utilizing half-cycle instantaneous power difference was proposed based on the subsynchronous frequency extraction. This method can locate the subsynchronous oscillation source for the centralized grid-connected system of multiple wind farms and support for cutting machines. To validate the suggested method, a doubly-fed induction generator was simulated in PSCAD by incorporating it into an infinite grid model using series complementation. The frequency extraction was carried out for the of three-phase symmetric and asymmetric situations in the subsynchronous frequency extraction example. When comparing the FFT analysis results, it shows that the instantaneous power-based frequency extraction results have good accuracy. For every 5 s increase in the studied time series, the computing time of the approach in this study grows by roughly 0.3 ms while the FFT method increases by about 2 ms, the difference between which is an order of magnitude. The result demonstrates how the suggested approach has clear advantages in the processing performance. Meantime, the approach reduces the possibility of spectrum leakage caused by discontinuous sampling endpoints in FFT analysis, and permits variable selection of truncation points for measurement data. The oscillation source identification was done for two scenarios in the multi-machine synchronous oscillation source identification examples: single oscillation source and multi-oscillation source. The simulations demonstrate that the voltage and current at the subsynchronous frequency of the generator where the oscillation source is located are larger than those at other generators. As a result, the corresponding half-cycle instantaneous power difference at the subsynchronous frequency has a larger amplitude. The findings can be used to accurately identify the oscillation source generators in the centralized grid-connected system of multiple wind farms. Furthermore, the magnitude of the absolute mean value of the half-cycle instantaneous power difference can be used to rank the significance of the oscillation sources and to rationally plan emergency response actions in the event of subsynchronous oscillations. The simulated analysis leads to the following conclusions: (1) The primary elements of the instantaneous power in the symmetric and asymmetric three-phase circuits are a constant power component and an alternating power component of subsynchronous frequency when the subsynchronous oscillation occurs in the wind power grid-connected system. (2) The frequency corresponding to the smallest absolute mean value of the whole-cycle instantaneous power difference is the subsynchronous oscillation frequency, based on which this paper suggests a method for extracting the subsynchronous oscillation frequency. The approach can avoid the picket fence effect problem and offers improved calculation accuracy and speed compared to FFT. (3) The oscillation source, the wind generator, in the centralized grid-connected system of multiple wind farms can be detected because the half-cycle instantaneous power difference of the oscillation source generator at the subsynchronous sampling period is the biggest.
[1] 肖湘宁, 罗超, 廖坤玉. 新能源电力系统次同步振荡问题研究综述[J]. 电工技术学报, 2017, 32(6): 85-97. Xiao Xiangning, Luo Chao, Liao Kunyu.Review of the research on subsynchronous oscillation issues in electric power system with renewable energy sources[J]. Transactions of China Electrotechnical Society, 2017, 32(6): 85-97. [2] 王伟胜, 张冲, 何国庆, 等. 大规模风电场并网系统次同步振荡研究综述[J]. 电网技术, 2017, 41(4): 1050-1060. Wang Weisheng, Zhang Chong, He Guoqing, et al.Overview of research on subsynchronous oscillations in large-scale wind farm integrated system[J]. Power System Technology, 2017, 41(4): 1050-1060. [3] 李明节, 于钊, 许涛, 等. 新能源并网系统引发的复杂振荡问题及其对策研究[J]. 电网技术, 2017, 41(4): 1035-1042. Li Mingjie, Yu Zhao, Xu Tao, et al.Study of complex oscillation caused by renewable energy integration and its solution[J]. Power System Technology, 2017, 41(4): 1035-1042. [4] Wang Liang, Xie Xiaorong, Jiang Qirong, et al.Investigation of SSR in practical DFIG-based wind farms connected to a series-compensated power system[J]. IEEE Transactions on Power Systems, 2015, 30(5): 2772-2779. [5] 张剑, 肖湘宁, 高本锋, 等. 双馈风力发电机的次同步控制相互作用机理与特性研究[J]. 电工技术学报, 2013, 28(12): 142-149, 159. Zhang Jian, Xiao Xiangning, Gao Benfeng, et al.Mechanism and characteristic study on sub-synchronous control interaction of a DFIG-based wind-power generator[J]. Transactions of China Electrotechnical Society, 2013, 28(12): 142-149, 159. [6] Xu Yanhui, Gao Tianchu.Sub-synchronous frequency domain-equivalent modeling for wind farms based on rotor equivalent resistance characteristics[J].Global Energy Interconnection, 5(3): 293-300. [7] 马闻达, 王西田, 解大. 大规模风电场并网系统次同步振荡功率传播特性研究[J]. 中国电机工程学报, 2020, 40(16): 5217-5229. Ma Wenda, Wang Xitian, Xie Da.Characteristics of subsynchronous oscillation power propagation in the large-scale wind farm integrated system[J]. Proceedings of the CSEE, 2020, 40(16): 5217-5229. [8] 丁屹峰, 程浩忠, 吕干云, 等. 基于Prony算法的谐波和间谐波频谱估计[J]. 电工技术学报, 2005, 20(10): 94-97. Ding Yifeng, Cheng Haozhong, Lü Ganyun, et al.Spectrum estimation of harmonics and interharmonics based on Prony algorithm[J]. Transactions of China Electrotechnical Society, 2005, 20(10): 94-97. [9] Yang Xiaomei, Zhang Jianing, Xie Xiaorong, et al.Interpolated DFT-based identification of sub-synchronous oscillation parameters using synch-rophasor data[J]. IEEE Transactions on Smart Grid, 2020, 11(3): 2662-2675. [10] Romano P, Paolone M.Enhanced interpolated-DFT for synchrophasor estimation in FPGAs: theory, implementation, and validation of a PMU prototype[J]. IEEE Transactions on Instrumentation and Measurement, 2014, 63(12): 2824-2836. [11] 马钺, 蔡东升, 黄琦. 基于Rife-Vincent窗和同步相量测量数据的风电次同步振荡参数辨识[J]. 中国电机工程学报, 2021, 41(3): 790-803. Ma Yue, Cai Dongsheng, Huang Qi.Parameter identification of wind power sub-synchronous oscillation based on Rife-Vincent window and synchrophasor data[J]. Proceedings of the CSEE, 2021, 41(3): 790-803. [12] 李天云, 赵妍, 季小慧, 等. HHT方法在电力系统故障信号分析中的应用[J]. 电工技术学报, 2005, 20(6): 87-91. Li Tianyun, Zhao Yan, Ji Xiaohui, et al.Application of HHT method for analysis of fault signal in electric power system[J]. Transactions of China Electrotechnical Society, 2005, 20(6): 87-91. [13] 王杨, 晁苗苗, 谢小荣, 等. 基于同步相量数据的次同步振荡参数辨识与实测验证[J]. 中国电机工程学报, 2022, 43(3): 899-908. Wang Yang, Chao Miaomiao, Xie Xiaorong, et al.Identification of subsynchronous oscillation parameters and field tests based on PMU data[J]. Proceedings of the CSEE, 2022, 43(3): 899-908. [14] Ma Yue, Huang Qi.Application of multisynchros-queezing transform for subsynchronous oscillation detection using PMU data[C]//2020 IEEE Industry Applications Society Annual Meeting, Detroit, MI, USA, 2021: 1-7. [15] Varma R K, Moharana A.SSR in double-cage induction generator-based wind farm connected to series-compensated transmission line[J]. IEEE Transactions on Power Systems, 2013, 28(3): 2573-2583. [16] Ali Mohammadpour H, Santi E.Modeling and control of gate-controlled series capacitor interfaced with a DFIG-based wind farm[J]. IEEE Transactions on Industrial Electronics, 2015, 62(2): 1022-1033. [17] Liu Huakun, Xie Xiaorong, Zhang Chuanyu, et al.Quantitative SSR analysis of series-compensated DFIG-based wind farms using aggregated RLC circuit model[J]. IEEE Transactions on Power Systems, 2017, 32(1): 474-483. [18] Karaagac U, Mahseredjian J, Jensen S, et al.Safe operation of DFIG-based wind parks in series-compensated systems[J]. IEEE Transactions on Power Delivery, 2018, 33(2): 709-718. [19] 余一平, 闵勇, 陈磊, 等. 基于能量函数的强迫功率振荡扰动源定位[J]. 电力系统自动化, 2010, 34(5): 1-6. Yu Yiping, Min Yong, Chen Lei, et al.Disturbance source location of forced power oscillation using energy functions[J]. Automation of Electric Power Systems, 2010, 34(5): 1-6. [20] 任怡娜, 陈磊, 闵勇, 等. 次同步振荡中暂态能量流与电功率和阻尼转矩的关系[J]. 电力系统自动化, 2018, 42(22): 52-58. Ren Yina, Chen Lei, Min Yong, et al.Relationship between transient energy flow, electric power and damping torque in subsynchronous oscillation[J]. Automation of Electric Power Systems, 2018, 42(22): 52-58. [21] Chen Lei, Min Yong, Chen Yiping, et al.Evaluation of generator damping using oscillation energy dissipation and the connection with modal analysis[J]. IEEE Transactions on Power Systems, 2014, 29(3): 1393-1402. [22] 陈剑, 杜文娟, 王海风. 基于对抗式迁移学习的含柔性高压直流输电的风电系统次同步振荡源定位[J]. 电工技术学报, 2021, 36(22): 4703-4715. Chen Jian, Du Wenjuan, Wang Haifeng.Location method of subsynchronous oscillation source in wind power system with VSC-HVDC based on adversarial transfer learning[J]. Transactions of China Electrotech-nical Society, 2021, 36(22): 4703-4715. [23] 陈剑, 杜文娟, 王海风. 采用深度迁移学习定位含直驱风机次同步振荡源机组的方法[J]. 电工技术学报, 2021, 36(1): 179-190. Chen Jian, Du Wenjuan, Wang Haifeng.A method of locating the power system subsynchronous oscillation source unit with grid-connected PMSG using deep transfer learning[J]. Transactions of China Electrotechnical Society, 2021, 36(1): 179-190. [24] Huang Tong, Freris N M, Kumar P R, et al.A synchrophasor data-driven method for forced oscillation localization under resonance conditions[J]. IEEE Transactions on Power Systems, 2020, 35(5): 3927-3939. [25] Liu Hao, Qi Yuan, Zhao Junbo, et al.Data-driven subsynchronous oscillation identification using field synchrophasor measurements[J]. IEEE Transactions on Power Delivery, 2022, 37(1): 165-175. [26] Li Jinsong, Liu Hao, Li Wenzhuo, et al.Data network traffic analysis and optimization strategy of real-time power grid dynamic monitoring system for wide-frequency measurements[J]. Global Energy Intercon-nection, 2022, 5(5): 131-142.