1.Department of Electrical Engineering Xi′an University of Technology Xi′an 710048 China; 2.State Key Lab of Electrical Insulation and Power Equipment Xi′an Jiaotong University Xi′an 710049 China
Abstract:High frequency pulsating signal injection (HFPSI) has strong robustness because it′s weak sensitivity for motor parameters variation and measurement errors.It shows favorable estimation performance for interior permanent magnet synchronous motors (PMSM) and surface-mounted PMSM at zero or low speed.However,the accuracy of the speed identification is directly related to the filter time constant.The HFPSI with fixed bandwidth filter has a good estimation accuracy only in the narrow speed range,at the same time the fixed bandwidth filter restricts the speed regulation range.A novel method of the HFPSI using the immune algorithm (IA) is proposed in this paper,and the IA is studied on the basis of the immune response system,the IA is also analyzed in this paper.After the IA is applied into HFPSI,the filter time constant can be adjusted on-line in the signal processing,meanwhile the problem that the fixed filter time constant of the HFPSI resulting in narrow speed regulation range can be overcome.The correctness and the effectiveness of the proposed method are verified by the simulation and experimental results.
尹忠刚,张彦平,张延庆,刘静,孙向东. 采用免疫高频脉动信号注入的PMSM转速辨识方法[J]. 电工技术学报, 2016, 31(增刊2): 243-254.
Yin Zhonggang,Zhang Yanping,Zhang Yanqing,Liu Jing,Sun Xiangdong. High Frequency Pulsating Signal Injection for Permanent Magnet Synchronous Machines Based on Immune Algorithm. Transactions of China Electrotechnical Society, 2016, 31(增刊2): 243-254.
[1] Lee J,Hong J,Nam K.Sensorless control of surface-mount permanent-magnet synchronous motors based on a nonlinear observer[J].IEEE Transactions on Power Electronics,2010,25(2):290-297. [2] 刘英培,栗然.一种永磁同步电机直接转矩控制无传感器运行优化方法[J].中国电机工程学报,2014,34(30):5368-5377. Liu Yingpei,Li Ran.An optimization method of direct torque control and sensorless operation for permanent magnet synchronous motors[J].Proceeding of the CSEE,2014,34(30):5368-5377. [3] 陆婋泉,林鹤云,冯奕,等.永磁同步电机无传感器控制的软开关滑模观测器[J].电工技术学报,2015,30(2):106-113. Lu Xiaoquan,Lin Heyun,Feng Yi,et al.Soft switching sliding mode observer for PMSM sensorless control[J].Transactions of China Electrotechnical Society,2015,30(2):106-113. [4] Wang Gaolin,Li Zhuomin,Zhang Guoqiang,et al.Quadrature PLL-based high-order sliding-mode observer for IPMSM sensorless control with online MTPA control strategy[J].IEEE Transactions on Energy Conversion,2013,28(1):214-224. [5] 李冉,赵光宙,徐绍娟.基于扩展滑模观测器的永磁同步电动机无传感器控制[J].电工技术学报,2012,27(3):79-85. Li Ran,Zhao Guangzhou,Xu Shaojuan.Sensorless control of permanent magnet synchronous motor based on extended sliding mode observer[J].Transactions of China Electrotechnical Society,2012,27(3):79-85. [6] 易伯瑜,康龙云,陶思念,等.基于两段卡尔曼滤波器的内置式永磁电机观测器设计[J].电工技术学报,2014,29(9):110-118. Yi Boyu,Kang Longyun,Tao Sinian,et al.Observer design of interior permanent magnet synchronous motors based on two-stage Kalman filter[J].Transactions of China Electrotechnical Society,2014,29(9):110-118. [7] 尹忠刚,肖鹭,孙向东,等.基于粒子群优化的感应电机模糊卡尔曼滤波器转速估计方法[J].电工技术学报,2016,31(6):55-65. Yin Zhonggang,Xiao Lu,Sun Xiangdong,et al.A speed estimation method of fuzzy extended Kalman filter for induction motors based on particle swarm optimization[J].Transactions of China Electrotechnical Society,2016,31(6):55-65. [8] Yin Zhonggang,Zhao Chang,Liu Jing,et al.Research on anti-error performance of speed and flux estimator for induction motor using robust reduced-order EKF[J].IEEE Transactions on Industrial Informatics,2013,9(2):1037-1046. [9] Habibullah M,Lu D D C.A speed-sensorless FS-PTC of induction motors using extended Kalman filters[J].IEEE Transactions on Industrial Electronics,2015,62(11):6765-6778. [10]朱瑛,程明,花为,等.基于滑模变结构模型参考自适应的电气无极变速器无传感器控制[J].电工技术学报,2015,30(2):64-72. Zhu Ying,Cheng Ming,Hua Wei,et al.Sensorless control for electrical variable transmission based on sliding mode model reference adaptive system[J].Transactions of China Electrotechnical Society,2015,30(2):64-72. [11]王庆龙,张兴,张崇巍.永磁同步电机矢量控制双滑模模型参考自适应系统转速辨识[J].中国电机工程学报,2014,34(6):897-902. Wang Qinglong,Zhang Xing,Zhang Chongwei.Double sliding-mode model reference adaptive system speed identification for vector control of permanent magnet synchronous motors[J].Proceeding of the CSEE,2014,34(6):897-902. [12]Teja A,Verma V,Chakraborty C.A new formulation of reactive-power-based model reference adaptive system for sensorless induction motor drive[J].IEEE Transactions on Industrial Electronics,2015,62(11):6797-6808. [13]Zbede Y B,Gadoue S M,Atkinson D J.Model predictive MRAS estimator for sensorless induction motor drives[J].IEEE Transactions on Industrial Electronics,2016,63(6):3511-3521. [14]Ogasawara S,Akagi H.Implementation and position control performance of a position-sensorless IPM motor drive system based onmagnetic saliency[J].IEEE Transac-tions on Industry Applications,1998,34(4):806-812. [15]Raca D,Garcia P,Reigosa D D,et al.Carrier-signal selection for sensorless control of PM synchronous machines at zero and very low speeds[J].IEEE Transactions on Industry Applications,2010,46(1):167-178. [16]Limsuwan N,Kato T,Yu C Y,et al.Secondary resistive losses with high-frequency injection-based self-sensing in IPM machines[J].IEEE Transactions on Industry Applications,2013,49(4):1499-1507. [17]Raca D,Harke M C,Lorenz R D.Robust magnet polarity estimation for initialization of PM synchronous machines with near-zero saliency[J].IEEE Transactions on Industry Applications,2008,44(4):1199-1209. [18]Garcia P,Briz F,Degner M W,et al.Accuracy,bandwidth,and stability limits of carrier-signal-injection-based sensorless control methods[J].IEEE Transactions on Industry Applications,2007,43(4):990-1000. [19]Luo Xin,Tang Qipeng,Shen Anwen,et al.PMSM sensorless control by injecting HF pulsating carrier signal into estimated fixed-frequency rotating reference frame[J].IEEE Transactions on Industrial Electronics,2016,63(4):2294-2303. [20]Yang S C,Lorenz R D.Surface permanent magnet synchronous machine position estimation at low speed using eddy-current-reflected asymmetric resistance[J].IEEE Transactions on Power Electronics,2012,27(5):2595-2604. [21]Yoon Y D,Sul S K.Sensorless control for induction machines based on square-wave voltage injection[J].IEEE Transactions on Power Electronics,2014,29(7):3637-3645. [22]Yang S C.Saliency-based position estimation of permanent-magnet synchronous machines using square-wave voltage injection with a single current sensor[J].IEEE Transactions on Industry Applications,2015,51(2):1561-1571. [23]Liu J M,Zhu Z Q.Novel sensorless control strategy with injection of high-frequency pulsationg carriar signal into stationary reference frame[J].IEEE Transactions on Industry Applications,2014,50(4):2574-2582. [24]Accetta A,Cirrincione M,Pucci M,et al.Sensorless control of PMSM fractional horsepower drives by signal injection and neural adaptive-band filtering[J].IEEE Transactions on Industrial Electronics,2012,59(3):1355-1366. [25]Yoon Y D,Sul S K,Morimoto S,et al.High-bandwidth sensorless algorithm for AC machines based on square-wave-type voltage injection[J].Transactions on Industry Applications,2011,47(3):1361-1370. [26]Liu J M,Zhu Z Q.Sensorless control strategy by square-waveform high-frequency pulsating signal injection into stationary reference frame[J].IEEE Transactions on Industry Applications,2014,2(2):171-180. [27]Yuan Jiaxin,Pan Jianbing,Fei Wenli,et al.An immune-algorithm-based space-vector PWM control strategy in a three-phase inverter[J].IEEE Transactions on Industrial Electronics,2013,60(5):2084-2093. [28]袁佳歆,薛刚,赵震,等.三相逆变器无死区最优矢量控制研究[J].电力系统保护与控制,2014,42(24):18-24. Yuan Jiaxin,Xue Gang,Zhao Zhen,et al.New optimal dead-time elimination for three-phase voltage source inverters[J].Power System Protection and Control,2014,42(24):18-24. [29]Zhu Q,Yin Z G,Zhang Y Q,et al.Research on two-degree-of-freedom internal model control strategy for induction motor based on immune algorithm[J].IEEE Transactions on Industrial Electronics,2016,63(3):1981-1992.