摘要 为解决消弧线圈接地电网单相接地故障测距困难的问题,提出一种基于最小二乘参数辨识的消弧线圈接地系统单相接地故障测距方法。以消弧线圈接地电网故障零序全波等效电路作为辨识模型,将故障距离、过渡电阻、对地电容作为模型的未知参数,利用该模型所反映的单相接地故障电压、电流时域关系构造参数辨识目标函数,用最小二乘辨识方法进行最优参数求解,得到故障位置到母线端的距离。对于带分支线路的情况,在参数辨识测距方法的基础上建立了推理判断逻辑,提高了测距方法的适用性。所提出的测距算法可集成在故障选线装置中,无需增加额外设备即可实现故障选线、测距一体化功能。仿真和实验验证了所提测距方法的有效性与准确性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
贾清泉
王振宇
王 宁
董海艳
艾 丽
关键词 消弧线圈接地电网单相接地故障故障测距零序全波等效电路最小二乘参数辨识    
Abstract:To deal with the fault locating problem against single-phase-to-ground fault in arc-suppression-coil earthed power distribution systems,a fault locating algorithm is presented for single-phase-to-ground fault in arc-suppression-coil earthed power distribution systems based on parameter estimation principle.By regarding the full-wave zero-sequence equivalent circuit as the estimation model and treating the fault distance,fault resistance and zero-sequence capacitance as the unknown parameters,the objective function of parameter estimation can be established according to the fault voltages and currents.The least-square estimation method is used to obtain the optimal parameters.So the distance between the fault location and the bus side can be obtained.In addition,considering branches likely existed in the distribution lines,deductive logics are constructed as the complement for the basic fault location method to improve the applicability of the method.The presented algorithm can be integrated in the fault selection device to implement the dual function without extra equipment.Simulations and experiments are conducted to verify the feasibility and accuracy of the proposed method.
Key wordsArc-suppression-coil earthed power distribution systems    single-phase-to-ground fault    fault location    zero-sequence full waveform equivalent circuit    least-square parameter estimation   
收稿日期: 2015-07-16      出版日期: 2016-12-26
PACS: TM77  
基金资助:国家自然科学基金项目资助(51477147)。
作者简介: 贾清泉 男,1970年生,教授,博士生导师,研究方向为配电网故障选线和故障定位技术,电能质量分析与治理。E-mail:jiaqingquan@sina.com王振宇 男,1990年生,硕士,研究方向为配电网故障定位技术。E-mail:1249132935@qq.com (通信作者)
引用本文:   
贾清泉, 王振宇 ,王 宁, 董海艳, 艾 丽. 基于参数辨识的消弧线圈接地电网单相接地故障测[J]. 电工技术学报, 2016, 31(23): 77-85. Jia Qingquan, Wang Zhenyu, Wang Ning ,Dong Haiyan, Ai Li. A Single-Phase-to-Ground Fault Locating Algorithm for Arc-Suppression-Coil Earthed Power Distribution Systems Based on Parameter Estimation. Transactions of China Electrotechnical Society, 2016, 31(23): 77-85.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/Y2016/V31/I23/77