1. Department of Electrical Power Engineering Shanghai Jiao Tong University Shanghai 200240 China; 2. Fujian Electric Power Test & Research Institute Fuzhou 350007 China; 3. Electrical Engineering and New Material Department of China Electric Power Research Institute Beijing 100192 China
Abstract:The flexible controlling of battery energy storage system is very suitable for the load shifting of power system. Based on the load forecasting, a threshold value considering power equalization can be set to determine the charging and discharging state of the storage system. However, the capacity of the storage system is limited in practice. So the scheme based on a single threshold value can be improved as a load interval. Once the running state of the system is determined, the value of real-time power exchange can be timeshare segment matched. Since there must be a deviation between real-time load and load forecasting, an adjustment method considering the predictive power of the storage system is proposed. The effectiveness and continuity of the scheme are verified by simulation.
尚瑨,邰能灵,刘琦,陈彬,陈金祥,惠东. 采用区间控制的蓄电池储能电站调峰运行控制策略[J]. 电工技术学报, 2015, 30(16): 221-229.
Shang Jin,Tai Nengling,Liu Qi,Chen Bin,Chen Jinxiang,Hui Dong. Load Shifting Scheme of Battery Energy Storage System Based on Interval Controlling. Transactions of China Electrotechnical Society, 2015, 30(16): 221-229.
[1] 周林, 黄勇, 郭珂, 等. 微电网储能技术研究综述[J]. 电力系统保护与控制, 2011, 39(7): 147-152. Zhou Lin, Huang Yong, Guo Ke, et al. A survey of energy storage technology for microgrid[J]. Power System Protection and Control, 2011, 39(7): 147-152. [2] 廖胜利, 程春田, 蔡华祥, 等. 改进的火电调峰方式[J]. 电力系统自动化, 2006, 30(1): 89-93. Liao Shengli, Cheng Chuntian, Cai Huaxiang, et al. Improved algorithm of adjusting discharge peak by thermal power plants[J]. Automation of Electric Power System, 2006, 30(1): 89-93. [3] 王鹏, 张灵凌, 梁琳, 等. 火电机组有偿调峰与无偿调峰划分方法探讨[J]. 电力系统自动化, 2010, 34(9): 87-91. Wang Peng, Zhang Lingling, Liang Lin, et al. A method for division of paid peak-regulation and free peak- regulation for thermal power units[J]. Automation of Electric Power System, 2010, 34(9): 87-91. [4] 张少华, 言茂松. 上海电网发展燃气轮机调峰的系统规划与优化[J]. 电网技术, 1996, 20(4): 27-32. Zhang Shanghua, Yan Maosong. Systematic planning and optimization for GAS turbine plants in Shanghai power system[J]. Power System Technology, 1996, 20(4): 27-32. [5] 王若谷, 王建学, 张恒, 等. 水电机组调峰服务的成本分析及实用补偿方法[J]. 电力系统自动化, 2011, 35(23): 41-47. Wang Ruogu, Wang Jianxue, Zhang Heng, et al. A cost analysis and practical compensation method for hydropower units peaking service[J]. Automation of Electric Power System, 2011, 35(23): 41-47. [6] 王金文, 范习辉, 张勇传, 等. 大规模水电系统短期调峰电量最大模型及其求解[J] 电力系统自动化, 2003, 27(15): 29-34. Wang Jinwen, Fan Xihui, Zhang Yongchuan, et al. Short-term generation schedule for the peak-energy maximization of large-scale hydropower systems[J]. Automation of Electric Power System, 2003, 27(15): 29-34. [7] Ali Nourai, Kogan V I, Chris M Schafer. Load leveling reduces T&D line losses[J]. IEEE Transactions on Power Delivery, 2008, 23(4): 2168-2173. [8] Sutanto D. Power management solutions for energy management, power quality and environment using battery energy storage systems[C]. IEEE 1999 Interna- tional Conference on Power Electronics and Drive Systems, Hong Kong, 1999, 1. [9] Zhou Haihua, Tanmoy Bhattacharya. Composite energy storage system involving battery and ultracapacitor with dynamic energy management in microgrid applica- tions[J]. IEEE Transactions on Power Electronics, 2011, 26(3): 923-930. [10] 丁明, 徐宁舟, 毕锐. 用于平抑可再生能源功率波动的储能电站建模及评价[J]. 电力系统自动化, 2011, 35(2): 66-72. Ding Ming, Xu Ningzhou, Bi Rui. Modeling of BESS for smoothing renewable energy output fluctuations [J]. Automation of Electric Power System, 2011, 35(2): 66-72. [11] Jeroen Tant, Frederik Geth, Daan Six. Multiobjective battery storage to improve PV integration in residential distribution grids[J]. IEEE Transactions on Sustainable Energy, 2013, 4(1): 182-192. [12] 严干贵, 冯晓东. 用于松弛调峰瓶颈的储能系统容量配置方法[J]. 中国电机工程学报, 2012, 32(28): 27-36. Yan Gangui, Feng Xiaodong. Optimization of energy storage system capacity for relaxing peak load regula- tion bottlenecks[J]. Proceedings of the CSEE, 2012, 32(28): 27-36. [13] Igor Papic, Member. IEEE simulation model for dischar- ging a lead-acid battery energy storage system for load leveling[J]. IEEE Transactions on Energy Conversion, 2006, 21(2): 608-616. [14] Ali Nourai, Kogan V I, Chris M Schafer. Load leveling reduces T&D line losses[J]. IEEE Transactions on Power Delivery, 2008, 23(4): 2168-2173. [15] Oudalov A Cher kaoui R, Beguin A. Sizing and optimal operation of battery energy storage system for peak shaving application[C]. 2007 IEEE Lausanne, Power Tech., 2007: 621-625. [16] Palomino E, Stevens J, Wiles J. A control system for improved battery utilization in a PV-powered peak- shaving system[C]. IEEE Conference Photovoltaic Specialists Conference, Washington DC, 1996: 1525- 1528. [17] Jeroen Tant, Frederik Geth, Daah Six. Multiobjective battery storage to improve PV integration in residential distribution grids[J]. IEEE Transactions on Sustainable Energy, 2013, 4(1): 182-192.