Abstract:The special environment in which the magnetic field is very weak and even nearly to zero hasunique and important applications in scientific and technology research.Through passive magnetic shielding,active compensation and other approaches,nearly zero magnetic fields can be realized in the ground condition with geomagnetic field and variable magnetic disturbances.Some high level nearly zero magnetic field environment facilities have been built in the world,and domestic researchers also have achieved some developments.Considering the recent developments in this field,the status reviews of these facilities including the construction design and performances are presented.
李立毅, 孙芝茵, 潘东华, 刘家曦,刘添豪. 近零磁环境装置现状综述[J]. 电工技术学报, 2015, 30(15): 136-140.
Li Liyi ,Sun Zhiyin ,Pan Donghua ,Liu Jiaxi, Liu Tianhao. Status Reviews for Nearly Zero Magnetic Field Environment Facility. Transactions of China Electrotechnical Society, 2015, 30(15): 136-140.
[1] Cohen D.A shielded facility for low-level magnetic measurements[J].Journal of Applied Physics,1967,38(3):1295-1296. [2] Cohen D.Large-volume conventional magnetic shields[J].Revue de Physique Appliquée,1970,5(1):53-58. [3] Mager A.Grossrumige magnetische abschirmungen[J].Journal of Magnetism and Magnetic Materials,1976,2(1):245-255. [4] Lequain P,Berkhout J A,Schouten J.Design and construction at ESTEC of a magnetically shielded enclosure for VLF[R].ESA TN-125,1977:1-32. [5] Kelh V.Construction and performance of the Otaniemi magnetically shielded room[C].Biomagnetism,Berlin,1981:33-50. [6] Erne S N,Hahlbohm H D,Scheer H,et al.The Berlin magnetically shielded room (BMSR),Section B:Performances[C].Biomagnetism,Berlin,1981:79-81. [7] Kajiwara G,Harakawa K,Ogata H,et al.High-performance magnetically shielded room[J].IEEE Transactions on Magnetics,1996,32(4):2582-2585. [8] Moon S H,Oh B,Kim H T,et al.Two-channel high-tc SQUID magnetometer for magnetocardiograms[J].Journal of the Korean Physical Society,1997,31(2):342-346. [9] Bork J,Hahlbohm H D,Klein R,et al.The 8-layered magnetically shielded room of the PTB:Design and construction[C].Biomag 2000,Proceeding 12th International Conference on Biomagnetism,Espoo Finland,2000. [10]Thiel F,Schnabel A,Knappe-Gruneberg S,et al.Demagnetization of magnetically shielded rooms[J].Review of scientific instruments,2007,78(3):035106-035106-13. [11]Cohen D,Schlpfer U,Ahlfors S,et al.New six-layer magnetically-shielded room for MEG[C].Biomagnetism,Jena,2002:919-921. [12]甘承德,瞿清昌.计量院卧佛寺弱磁实验室筹建纪实[J].中国计量,2005,1(11):46-48. [13]张志友,李嘉璋,刘建本,等.零磁室内环境磁场噪声的测定[J].烟台大学学报 (自然科学与工程版),1989,1 (2):37-41. [14]程华富.交变微弱磁场标准研究[J].水雷战与舰船防护,2009,17(1):9-12. Cheng Huafu.Research on alternating weak magnetic field standards[J].Mine Warfare & Ship Self-Defence,2009,17(1):9-12. [15]Soltner H,Pabst U,Butzek M,et al.Design,construction,and performance of a magnetically shielded room for a neutron spin echo spectrometer[J].Nuclear Instruments and Methods in Physics Research Section A:Accelerators,Spectrometers,Detectors and Associated Equipment,2011,644(1):40-47. [16]Dickerson S,Hogan J M,Johnson D M S,et al.A high-performance magnetic shield with large length-to-diameter ratio[J].Review of Scientific Instruments,2012,83(6):065108. [17]Altarev I,Babcock E,Beck D,et al.A magnetically shielded room with ultra low residual field and gradient[J].Review of Scientific Instruments,2014,85(7):075106.