Abstract:To investigate the humidity impact on radio interference due to positive corona, a positive corona discharge experimental platform for stranded conductor is built. To get rid of the influence of other factors, the relative humidity is taken as the unique variable which is artificially controlled in the range of 40%~85%. Applying the impedance-matching technique to the test line’s terminals, the corona current pulses on the stranded conductor are accurately measured and the influence of the humidity on positive corona current pulses and their radio interference is investigated. Some regularities are found as the humidity increases: new discharge points arises,whereas the amplitudes of the pulses produced by the new discharge points are usually very small; the average amplitude of the corona pulses decreases and the repetition rate of the corona pulses firstly increases and attains the maximum at humidity of 60%~75%, and then decreases as the humidity further increases; the rise time, time to half value and duration time of the pulse will be greatly shortened in the range of 40%~60%, whereas no regularities are found in the range of 60%~80%; the spectral density of the corona current decreases, which means that an increase of humidity will cause a decrease of radio interference.
刘阳,崔翔,卢铁兵,向宇,王小波,李学宝,张宏. 湿度对绞线正极性电晕电流脉冲及其无线电干扰影响的实验[J]. 电工技术学报, 2015, 30(3): 79-89.
Liu Yang,Cui Xiang,Lu Tiebing,Xiang Yu,Wang Xiaobo,Li Xuebao,Zhang Hong. Experimental Investigation of Humidity Impact on Positive Corona Current Pulse and Its Radio Interference of Stranded Conductors. Transactions of China Electrotechnical Society, 2015, 30(3): 79-89.
[1] Khalifa M, El-Debeiky S. Analysis of the effect of humidity on d. c. corona power losses[J]. Proceedings of the Institution of Electrical Engineers, 1971, 118(5): 714-718. [2] Allen N L, Berger G, Dring D, et al. Effects of humidity on corona inception in a diverging electric field[J]. IEE Proceedings of a Physical Science, Measurement and Instrumentation, Management and Education- Reviews, 1981, 128(8): 565-570. [3] Fouad L, Elhazek S. Effect of humidity on positive corona discharge in a three electrode system[J]. Journal of Electrostatics, 1995, 35(1): 21-30. [4] Bian X M, Meng X B, Wang L M, et al. Negative corona inception voltages in rod-plane gaps at various air pressures and humidities[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2011, 18(2): 613-619. [5] 惠建峰, 关志成, 王黎明, 等. 正直流电晕特性随气压和湿度变化的研究[J]. 中国电机工程学报, 2007, 27(33): 53-58. Hui Jianfeng, Guan Zhicheng, Wang Liming, et al. Research on variation of positive DC corona character- ristics with air pressure and humidity[J]. Proceedings of the CSEE, 2007, 27(33): 53-58. [6] 卞星明, 惠建峰, 黄海鲲, 等. 气压湿度对负直流电晕特性影响的研究[J]. 中国电机工程学报, 2010, 30(4): 118-124. Bian Xingming, Hui Jianfeng, Huang Haikun, et al. Effects of air pressure and humidity on the charateristics of negative DC corona[J]. Proceedings of the CSEE, 2010, 30(4): 118-124. [7] Bian X M, Wang L M, MacAlpine J M K, et al. Positive corona inception voltages and corona currents for air at various pressures and humidities[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2010, 17(1): 63-70. [8] 安冰, 丁燕生, 王伟, 等. 湿度对电晕笼中导线直流电晕特性的影响[J]. 电网技术, 2008, 32(24): 98-101. An Bing, Ding Yansheng, Wang Wei, et al. Influence of humidity on corona performance of DC conductor in corona cage[J]. Power System Technology, 2008, 32(24): 98-101. [9] Hu Q, Shu L, Jiang X, et al. Effects of air pressure and humidity on the corona onset voltage of bundle conductors[J]. IET Generation, Transmission & Distri- bution, 2011, 5(6): 621-629. [10] Xu M M, Tan Z Y, Li K J. Modified Peek formula for calculating positive DC corona inception electric field under variable humidity[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2012, 19(4): 1377-1382. [11] Wang X H, You C F. Effect of humidity on negative corona discharge of electrostatic precipitators[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2013, 20(5): 1720-1726. [12] Meng X B, Hui J F, Mei H W, et al. Influence of pressure and humidity on the amplitude-phase distribu- tion of AC corona pulse[C]. Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2013: 838-841. [13] Nouri H, Zouzou N, Moreau E, et al. Effect of relative humidity on current-voltage characteristics of an electrostatic precipitator[J]. Journal of Electrostatics, 2012, 70(1): 20-24. [14] Allen N L. Corona, breakdown and humidity in the rod- plane gap[J]. IEE Proceedings a Physical Science, Measurement and Instrumentation, Management and Education-Reviews,1986, 133(8): 562-568. [15] Boutlendj M, Allen N L, Lightfoot H A, et al. Positive DC corona and sparkover in short and long rod-plane gaps under variable humidity conditions[J]. IEE Proc. -A, 1991, 138(1): 31-36. [16] Rodriguez D, Gorur R S, Hansen P M. Effect of humidity on the breakdown characteristics of air in non-uniform fields at 30kHz[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2010, 17(1): 45-52. [17] Peyrous R. The effects of relative humidity on ozone production by corona discharge in oxygen or air-a numerical simulation-part I: oxygen[J]. Ozone Science and Engineering, 1990, 12(1): 19-40. [18] Peyrous R. The effects of relative humidity on ozone production by corona discharge in oxygen or air-a numerical simulation-part II: air[J]. Ozone Science and Engineering, 1990, 12(1): 41-64. [19] Chen J, Wang P. Effect of relative humidity on electron distribution and ozone production by DC coronas in air[J]. IEEE Transactions on Plasma Science, 2005, 33(2): 808-812. [20] Hui J F, Guan Z C, Wang L M, et al. Variation of the dynamics of positive streamer with pressure and humidity in air[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008, 15(2): 382-389. [21] 卞星明, 惠建峰, 黄海鲲, 等. 气压和湿度对正直流电晕流注脉冲特性的影响[J]. 高电压技术, 2009, 35(10): 2371-2382. Bian Xingming, Hui Jianfeng, Huang Haikun, et al. Influence of air pressure and humidity on positive DC corona streamer pulse characteristics[J]. High Voltage Engineering, 2009, 35(10): 2371-2382. [22] 蒋虹, 陈豫朝, 张广洲, 等. 温湿度对交流电晕无线电干扰的影响[J]. 高电压技术, 2011, 37(12): 2918-2923. Jiang Hong, Chen Yuchao, Zhang Guangzhou, et al. Effect of temperature and humidity on radio interference generated from AC corona[J]. High Voltage Engineering, 2011, 37(12): 2918-2923. [23] Liu Yang, Cui Xiang, Lu Tiebing, et al. Accurate measurement of original current pulses because of positive corona in the coaxial cylindrical arrangement [J]. IET Science, Measurement & Technology, accepted. [24] 张峰, 石现峰, 张学智. Welch功率谱估计算法仿真及分析[J]. 西安工业大学学报, 2009, 29(4): 353-356. Zhang Feng, Shi Xianfeng, Zhang Xuezhi. Study and simulation of Welch power spectrum estimation method [J]. Journal of Xi’an Technological University, 2009, 29(4): 353-356. [25] Malik N H, Al-rainy A A. Statistical variation of DC corona pulse amplitudes in point-to-plane air gaps[J]. IEEE Transactions on Electrical Insulation, 1987, EI-22(6): 825-829. [26] Maruvada P S. Corona performance of high-voltage transmission lines[M]. Baldock: Research Studies Press, 2000. [27] Chervenak J G, Van Lint V A J. Electron-ion recom- bination in air at EMP fields[J]. IEEE Transactions on Nuclear Science, 1985, 32(6): 4308-4311. [28] Sakata S, Okada T. Effect of humidity on hydrated cluster-ion formation in a clean room corona discharge neutralizer[J]. Journal of Aerosol Science, 1994, 25(5): 879-893. [29] Trinh N G. Partial discharge XIX: Discharge in air Part I: Physical mechanisms[J]. IEEE Electrical Insulation Magazine, 1995, 11(2): 23-29. [30] Otto A J. Direct current conductor corona modeling and metrology:[D]. Stellenbosch, South Africa: Univer- sity of Stellenbosch, 2009. [31] DL/T 691-1999, 高压架空送电线路无线电干扰计算方法[S]. [32] Liao T W, Keen W A, Powell D R. Relationship between corona and radio influence on transmission lines, laboratory studies I-point and conductor corona [J]. Transactions of the American Institute of Electrical Engineers on Power Apparatus and Systems, Part III, 1954, 76(3): 530-538. [33] Nigol O. Analysis of radio noise from high-voltage lines I-meter response to corona pulses[J]. IEEE Transactions on Power Apparatus and Systems, 1964, 83(5): 524-533. [34] Maruvada P S, Hylten-Cavallius N, Chinh N T. Radio noise meter response to random pulses by computer simulation[J]. IEEE Transactions on Power Apparatus and Systems, 1974, 93(3): 905-915. [35] Maruvada P S, Trinh N G, Dallaire D, et al. Corona performance of a conductor bundle for bipolar HVDC transmission at ±750kV[J]. IEEE Transactions on Power Apparatus and Systems, 1977, 96(6): 1872-1882. [36] Maruvada P S, Trinh N G, Dallaire R D, et al. Corona studies for bipolar HVDC transmission at voltages between ±600kV and ±1 200kV Part 1: Long-term bipolar line studies[J]. IEEE Transactions on Power Apparatus and Systems, 1981, 100(3): 1453-1461. [37] Maruvada P S, Dallarie R D, Heroux P, et al. Corona studies for bipolar HVDC transmission at voltages between ±600kV and ±1200kV Part 2: Special bipolar line, bipolar cage and bus studies[J]. IEEE Transactions on Power Apparatus and Systems, 1981, 100(3): 1462- 1471. [38] Maruvada P S, Dallaire R D, Heroux P, et al. Long- term statistical study of the corona electrical field and ion-current performance of a ±900kV bipolar HVDC transmission line configuration[J]. IEEE Power Enginee- ring Review, 1984, 4(1): 33-33.