Abstract:Aiming at three-level NPC(Neutral-point Clamped) traction inverter and traction motor system for high-speed trains, a hardware-in-the-loop application research of beat-less control scheme was adopted. Firstly, mathematical model of traction main circuit is analyzed in detailed. Secondly, considering the effect of dead-time and PWM sample signal’s error, the real-time hardware-in-the-loop model for the three-level inverter and motor system based on dSPACE platform is built. After that, in order to restrain the beat frequency phenomenon occurred with single-pulse control in the region of constant-voltage variable-frequency operation, a beat-less control algorithm, with the characteristic of transient change of inverter’s output frequency and rotor field oriented vector control, is proposed. The control principal of this algorithm is derived from volt-second balance theory. And as the result of control, the unbalance of positive and negative period of inverter’s output voltage is decreased deeply. At last, the real-time simulation comparison for this system with and without beat-less control was carried out, the simulation results prove its validity and feasibility.
葛兴来, 冯晓云, 韩坤, 宋文胜. 三电平牵引变流器无拍频控制的硬件在回路实时仿真[J]. 电工技术学报, 2014, 29(8): 204-210.
Ge Xinglai, Feng Xiaoyun, Han Kun, Song Wensheng. Hardware-in-the-Loop Application of Beat-less Control Scheme for Three-Level Traction Inverter System. Transactions of China Electrotechnical Society, 2014, 29(8): 204-210.
[1] 冯晓云. 电力牵引交流传动及其控制系统[M]. 北京: 高等教育出版社, 2009. [2] 姜卫东, 王群京, 陈权, 等. 一种完全基于两电平空间矢量调制的三电平空间矢量调制算法[J]. 电工技术学报, 2009, 24(1): 108-114. Jiang Weidong, Wang Qunjing, Chen Quan, et al. SVPWM strategy for three-level inverter based on SVPWM stratety for two-level inverter[J]. Transactions of China Electrotechnical Society, 2009, 24(1): 108-114. [3] 胡海兵, 姚文熙, 吕征宇. 三电平空间矢量调制的FPGA实现[J]. 电工技术学报, 2010, 25(5): 116-128. Hu Haibing, Yao Wenxi, Lü Zhengyu. Realization of three level SVPWM using FPGA[J]. Transactions of China Electrotechnical Society, 2010, 25(5): 116-128. [4] 葛兴来, 冯晓云. 动车组牵引传动三电平逆变器SVPWM控制[J]. 西南交通大学学报, 2008, 43(5): 566-572. Ge Xinglai, Feng Xiaoyun. SVPWM control of three level inverter for traction drive in EMUs[J]. Journal of Southwest Jiaotong University, 2008, 43(5): 566-572. [5] 葛兴来, 冯晓云. 三电平逆变器无拍频控制策略研究[J]. 铁道学报, 2010, 32(3): 125-130. Ge Xinglai, Feng Xiaoyun. Research on beat-less control technology in three level inverter[J]. Journal of the China Railway Society, 2010, 32(3): 125-130. [6] Kimura A. Frequency domain analysis of beat-less control method for converter-inverter driving systems applied to AC electric cars[J]. IEEE Transactions on Industry Applications, 2008, 128(11): 1269-1274. [7] Konda K, Hata H, Yuki K, et al. Development of permanent magnet synchronous motor control system for the traction purpose of the gauge changing train[J]. IEEE Transactions on Industry Applications, 2005, 125(4): 348-354. [8] Ouyang Hui, Zhang Kai, Zhang Penju, et al. Repetitive compensation of fluctuating DC link voltage for railway traction drives[J]. IEEE Transactions on Power Electronics, 2011, 26(8): 2160-2171. [9] Lee B K, Ehsami M. A simplified functional simulation model for three-phase voltage-source inverter using switching function concept[J]. IEEE Transactions on Industrial Electronics, 2001, 48(2): 309-321. [10] 丁荣军, 桂卫华, 陈高华. 电力机车交流传动系统的半实物实时仿真[J]. 中国铁道科学, 2008, 29(4): 96-102. Ding Rongjun, Gui Weihua, Chen Gaohua. HIL real- time simulation of electric locomotive AC drive system [J]. China Railway Science, 2008, 29(4): 96- 102. [11] Terwiesch P, Keller T, Scheiben E. Rail vehicle control system integration testing using digital hardware-in-the-loop simulation[J]. IEEE Transac- tions on Control Systems, 1999, 7(3): 352-362. [12] Faruque M O, Dinavahi V, Xu W. Algorithms for the accounting of multiple switching events in digital simulation of power-electronic systems[J]. IEEE Transactions on Power Delivery, 2005, 20(2): 1157- 1167.