Abstract:The operation principles of peak current controlled, V2 controlled, and V2C controlled buck converter operating in continuous conduction mode (CCM) are analyzed and compared respectively. It is pointed out that V2C control is essentially a kind of control technique by utilizing peak capacitor voltage and inductor current, quite similar to peak current control. It is also pointed out that both peak current control and V2 control are special case of V2C control. Stability of V2C controlled Buck converter operating in CCM is analyzed in time-domain and frequency-domain respectively. Sub-harmonic oscillation of V2C controlled Buck converter operating in CCM when duty ratio is higher than 0.5 (D> 0.5) can be eliminated by using slope compensation. Simulation and experiment results are given to verify our theory analysis.
[1] Mammano R. Switching power supply topology voltage mode vs current mode[M]. Unitrode Product & Applications Handbook, 1995-1996. Order Number DN-62. [2] 林维明. 具有快速负载动态响应的DC/DC开关变换器控制新策略[J]. 中国电机工程学报, 2001, 21(9): 78-81. [3] Mitchell D M. An analytical investigation of current-injected control for constant-frequency switching regulators[J]. IEEE Transactions on Power Electronics, 1986, 1(3): 167-174. [4] Middlebrook R D. Topics in multiple-loop regulators and current-mode programming[C]. IEEE Power Electronics Specialists Conference, 1985: 716-732. [5] 吴忠, 李红, 左鹏, 等. DC/DC升压变换器串级控制[J]. 中国电机工程学报, 2002, 22(1): 110-115. [6] 王毅, 陈希有, 徐殿国. 双电压合成矩阵变换器闭环控制的研究[J]. 中国电机工程学报, 2002, 22(1): 74-79. [7] Goder D, Pelletier W. V2 architecture provides ultra-fast transient response in switch power supplies[C]. Proceedings of High Frequency Power Conversion, Las Vegas, Nevada, 1996: 19-23. [8] 王凤岩, 许建平, 许峻峰. V2控制Buck变换器分 析[J]. 中国电机工程学报, 2005, 25(12): 67-72. [9] 王凤岩, 许建平. 不连续导电模式V2控制Buck变换器分析[J]. 电工技术学报, 2005, 20(10): 35-40. [10] Qu S. Modeling and design considerations of V2 controlled buck regulator[C]. IEEE Applied Power Electronics Conference and Exposition, USA, 2001: 507-513. [11] Wang F, Wu S, Xu J, et al. Modeling and simulation of V2 controlled switching converters[C]. IEEE International Conference on Power Electronics and Drive Systems, Singapore, 2003: 613-617. [12] Schuellein G. Current sharing of redundant synchronous buck regulators powering high performance microprocessors using the V2 control method[C]. IEEE Applied Power Electronics Conference and Exposition, USA, 1998: 853-859. [13] 王凤岩, 许建平. V2C控制Buck变换器分析[J]. 中国电机工程学报, 2006, 26(2): 121-126. [14] 王凤岩, 许建平. 不连续导电模式V2C控制Boost变换器分析[J]. 电气应用, 2007, 26(6): 62-65. [15] Deisch C. Simple switching control method changes power converter into a current source[C]. IEEE Power Electronics Specialists Conference, 1978: 300-306. [16] 何亮, 方宇, 李吉, 等. 峰值电流控制DC/DC变换器的恒值限流方法[J]. 电工技术学报, 2006, 21(10): 86-89. [17] Wang F, Xu J, Xu J. Small-signal model of V2 control technique with compensation[C]. IEEE International Conference on Communications, Circuits and Systems, China, 2004: 1358-1362. [18] Sun J. Characterization and performance comparison of ripple-based control for voltage regulator modules[J]. IEEE Transactions on Power Electronics, 2006, 21(2): 346-353.