Dynamic Analysis and Elimination of DC Component of Grid Connected Voltage Controlled Inverter |
Gao Jiayuan, Zhao Jinbin, He Chaojie, Zhang Shuaitao, Qu Keqing |
College of Electrical Engineering Shanghai College of Electric Power Shanghai 200090 China |
|
|
Abstract This paper focusses on the problem of direct current injection caused by voltage-controlled inverter connection. Based on the axial-voltage regulation single phase LCL inverter, the mathematical model of grid connected inverter has been built. This paper shows the details of mathematical analysis and formula derivation by analyzing the reasons of DC component indection. The result shows that the DC component has a nearly linear relationship with the voltage amplitude and frequency. Thus, this paper proposes the current deviation compensation (CDC) control strategy to diminish and eliminate the impacts of DC component. This strategy can compensate the injection direct current when the grid voltage and frequency fluctuation happen. The CDC control can also improve the performance of voltage-controlled inverter at the same time. Finally, simulation and experiment verify the effectiveness of the proposed control strategy.
|
Received: 11 January 2016
Published: 30 August 2017
|
|
|
|
|
[1] 刘鸿鹏, 王卫, 吴辉. 光伏逆变器的调制方式分析与直流分量抑制[J]. 中国电机工程学报, 2010, 30(9): 27-32. Liu Hongpeng, Wang Wei, Wu Hui. Modulation mode analysis and suppressing DC current of PV inverter[J]. Proceedings of the CSEE, 2010, 30(9): 27-32. [2] 杨晓光, 姜龙斌, 冯俊博, 等. 一种新型高效无变压器型单相光伏逆变器[J]. 电工技术学报, 2015, 30(8): 97-103. Yang Xiaoguang, Jiang Longbin, Feng Junbo, et al. A new high efficiency transformerless single-phase photovoltaic inverter[J]. Transactions of China Elec- trotechnical Society, 2015, 30(8): 97-103. [3] Roberto G, Eugenio G, Jesus L. Transformerless single-phase multilevel-based photovoltaic inverter[J]. IEEE Transactions on Industrial Electronics, 2008, 55(7): 2694-2702. [4] Armstrong M, Atkinson D J, Mark Johnson C. Auto- calibrating DC link current sensing technique for transformerless grid connected H-bridge inverter systems[J]. IEEE Transactions on Power Electronics, 2006, 21(5): 1385-1393. [5] 陈堃, 刘涤尘, 陈昌旺. 基于改进重复控制的光伏并网逆变器直流注入抑制策略[J]. 电工技术学报, 2013, 28(10): 159-166. Chen Kun, Liu Dichen, Chen Changwang. A strategy for restraining DC injection of photovoltaic grid- connected inverters based on improved repetitive control[J]. Transactions of China Electrotechnical Society, 2013, 28(10): 159-166. [6] Blewitt W M, Atkinson D J, Kelly J, et al. Approach to low-cost prevention of DC injection in transfor- merless grid connected inverters[J]. IET Power Electron, 2010, 3(1): 111-119. [7] Berba F, Atkinson D, Armstrong M. A review of minimisation of output DC current component methods in single-phase grid-connected inverters PV applications[C]//The 2nd International Symposium on Environment-Friendly Energies and Applications, Tyne, UK, 2012: 296-301. [8] 周林, 杨冰, 郭珂, 等. 光伏并网系统中直流注入问题最新进展及发展趋势[J]. 电力系统保护与控制, 2012, 40(6): 147-155. Zhou Lin, Yang Bing, Guo Ke, et al. The progress and development trend of the DC injection issue in PV grid-connected systems[J]. Power System Pro- tection and Control, 2012, 40(6): 147-155. [9] 王宝诚, 郭小强, 梅强, 等. 无变压器非隔离型光伏并网逆变器直流注入控制技术[J]. 中国电机工程学报, 2009, 29(36): 23-28. Wang Baocheng, Guo Xiaoqiang, Mei Qiang, et al. DC injection control for transformerless PV grid- connected inverters[J]. Proceedings of the CSEE, 2009, 29(36): 23-28. [10] Yan Q, Wu X, Yuan X, et al. Minimization of the DC component in transformerless three-phase grid- connected photovoltaic inverters[J]. IEEE Transa- ctions on Power Electronics, 2015, 30(7): 3984- 3997. [11] Gonzalez R, Lopez J, Sanchis P, et al. Trans- formerless inverter for single-phase photovoltaic systems[J]. IEEE Transactions on Power Electronics, 2007, 22(2): 693-697. [12] Lopez O, Teodorescu R, Gandoy J D. Multilevel transformerless topologies for single-phase grid- connected converters[C]//IEEE Proceedings of IECON, Paris, France, 2006: 5191-5196. [13] Bowtell L, Ahfock A. Direct current offset controller for transformerless single-phase photovoltaic grid- connected inverters[J]. IET Renewable Power Generation, 2010, 4(5): 428-437. [14] Buticchi G, Consolini L, Lorenzani E. Active filter for the removal of the DC current component for single-phase power lines[J]. IEEE Transactions on Industrial Electronics, 2013, 60(10): 4403-4414. [15] Wang B, Guo X, Gu H, et al. Real-time DC injection measurement technique fortransformerless PV systems[C]//IEEE International Symposium on Power Electronics for Distributed Generation Systems, Hefei, 2010: 980-983. [16] 张元吉, 赵晋斌, 王亚维, 等. 基于等效内部阻抗的单相电压控制型逆变器控制策略[J]. 电网技术, 2014, 38(2): 478-483. Zhang Yuanji, Zhao Jinbin, Wang Yawei. Control scheme of single-phase voltage-controlled inverter based on equivalent inner impedance[J]. Power System Technology, 2014, 38(2): 478-483. [17] 王亚维, 赵晋斌, 屈克庆, 等. 基于轴压调节的电压控制型逆变器的并网运行模式[J]. 电力系统自动化, 2015, 39(15): 110-116. Wang Yawei, Zhao Jinbin, Qu Keqing, et al. Grid- tied mode for voltage-controlled inverter with axes[J]. Automation of Electric Power System, 2015, 39(15): 110-116. [18] 赵晋斌, 张元吉, 屈克庆, 等. 单相LCL并网逆变器控制策略综述[J]. 电工技术学报, 2013, 28(10): 134-142. Zhao Jinbin, Zhang Yuanji, Qu Keqing, et al. Overview of control strategy for single-phase grid- connected inverter with LCL filter[J]. Transactions of China Electrotechnical Society, 2013, 28(10): 134-142. |
|
|
|