Abstract:Mine communication cable is a kind of primary transmission line transmitting the monitor signal. As lack of test data, the primary electric parameter models of mine communication cable cannot be established, so it is difficult to analyze the transmission characteristics of mine monitor. Referencing the BT#0 numerical model and common twisted pair model parameters of six gauges and using the data fitting method, this paper calculates the numerical model parameters of three kinds of mine cables and establishes the models. According to the models, the characteristics of primary electric parameters of mine communication cable are studied.
[1] 孙继平. 矿井安全监控系统[M]. 北京: 煤炭工业出版社, 2006. [2] 成凌飞. 矿用ADSL传输性能研究[D]. 北京: 中国矿业大学(北京), 2008. [3] 穆道生. 现代化光纤通信系统[M]. 北京: 科学出版社, 2005. [4] Lindholm M.Characteristics of twisted pair cables in Finland[C]. ETSI-TM6 Contribution TD22, Tel Aviv, Israel, 1997. [5] Musson J.Maximum likelihood estimation of the primary parameters of twisted pair cables[C]. ETSI-TM6 Contribution TD8, Madrid, Spain, 1998. [6] Pythoud F. Model of swiss access network cables[C]. ETSI-TM6 Contribution TD48, Madrid, Spain, 1998. [7] Van den Brink R. Measurements and models on Dutch cables[C]. ETSI-TM6 Contribution TD15, Tel Aviv, Israel, 1997. [8] Van den Brink R.A round robin test on cable measurements[C]. ETSI-TM6 Contribuion TD16, Tel Aviv, Israel, 1997. [9] Vautier M.RLCG parameters for France telecom copper cables[C]. ETSI-TM6 Contribution TD25, Sophia Antipolis, France, 1996. [10] Van den Brink R. Cable reference models for simulating metallic access networks[C]. ETSI STC TM6, 1998. [11] Rauschmayer D J. ADSL/VDSL principles[M]. Indiana: Macmillan Technical Publishing, 1999. [12] 任玉杰. 数值分析及其Matlab实现[M]. 北京: 高等教育出版社, 2007.