A Low Voltage Ride-Through of Strategy for Doubly Fed Induction Generator
Yu Lan1, 2, 3, Chen Guocheng1, 2, Song Xiaoliang1, 2, Cao Dapeng1, 2, Wu Guoxiang1, 2
1. Shanghai University Shanghai 200072 China 2. Shanghai Key Laboratory of Power Station Automation Technology Shanghai 200072 China 3. Shanghai University of Engineering Science Shanghai 201620 China
Abstract:Grid faults cause series of problems for doubly fed induction generator (DFIG) such as over current in both stator and rotor by using traditional DFIG control methods. In order to solve these problems, DFIG needs low voltage rid through (LVRT) ability. Based on the DFIG characteristics during the symmetric grid fault, this paper proposes DFIG rotor side converter LVRT control method to improve the DFIG over current. Based on theoretic analysis, the modes of LVRT control strategy are established. A 3kW DFIG excitation control experimental system is established. The test results prove the LVRT control method of DFIG to be effective.
蔚兰, 陈国呈, 宋小亮, 曹大鹏, 吴国祥. 一种双馈感应风力发电机低电压穿越的控制策略[J]. 电工技术学报, 2010, 25(9): 170-175.
Yu Lan, Chen Guocheng, Song Xiaoliang, Cao Dapeng, Wu Guoxiang. A Low Voltage Ride-Through of Strategy for Doubly Fed Induction Generator. Transactions of China Electrotechnical Society, 2010, 25(9): 170-175.
[1] Eduard Muljadi, C P Butterfield, Brian Parsons, et al. Effect of variable speed wind turbine generator on stability of a weak grid[J]. IEEE Transactions on Energy Conversion, 2007, 22(1): 29-36. [2] 向大为, 杨顺昌, 冉立. 电网对称故障时双馈感应发电机不脱网运行的励磁控制策略[J]. 中国电机工程学报, 2006, 26(3): 164-170. [3] Morren J, Sjoerd W H de Haan. Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip[J]. IEEE Transactions on Energy Conversion, 2005, 20(1): 435-441. [4] Dittrich A, Stoev A. Comparison of fault ride-through strategies for wind turbines with DFIM generators[C]. 2005 European Conference on Power Electronics and Applications, 2005:1-8. [5] Abbey C, Joos G. Short-term energy storage for wind energy applications[C]. Industry Applications Conference, 2005: 2035-2042. [6] 胡家兵, 孙丹, 贺益康, 等. 电网电压骤降故障下双馈风力发电机建模与控制[J]. 电力系统自动化, 2006, 30(8): 21-26 Hu Jiabing, Sun Dan, He Yikang, et al. Modeling and control of DFIG wind energy generator system under grid voltage dip[J]. Automation of Electric Power System, 2006, 30(8): 21-26. [7] Dawei Xiang, Li Ran, Tavner P J, et al. Control of a doubly fed induction generator in a wind turbine during grid fault ride-through[J]. IEEE Transactions on Energy Conversion, 2006, 21(3): 652-662. [8] Manoj R Rathi, Ned Mohan A. A novel robust low voltage and fault rtide through for wind turbine application operating in weak grids[C]. Industrial Electronics Society, IECON, 2005: 2481-2486. [9] Jesus Lopez, Eugenio Gubia, Pablo Sanchis. Wind turbines based on doubly fed induction generator under asymmetrical voltage dips[J]. IEEE Transaction on Energy Conversion, 2008, 23(1): 321- 329. [10] 吴春华, 陈国呈, 丁海洋, 等. 一种新型光伏并网逆变器控制策略[J]. 中国电机工程学报, 2007, 27 (33): 103-107.