Abstract:Based on the equivalent circuit of a 3-phase 4-wire generator-rectifier system, this paper presents the dynamic average-value model (AVM) of 4-wire diode-bridge rectifier under continuous conduction mode (CCM) using state-space averaging method. The AVM is validated by the corresponding switching model of rectifier by simulations in the Matlab/Simulink environment, and by a hardware test system composed of a synchronous generator and its 3-phase 4-wire diode-bridge rectifier load. The results show that the AVM can captures the key steady-state and transient characteristics of the rectifier, and the agreement of DC voltage between the AVM, the switching model, and the hardware circuit are well. The model presented herein can be used for modeling, impedance mapping, and stability assessment with small disturbance of such generator (transformer) -rectifier systems.
[1] Wu Bin. High-power converters and AC drives[M]. New Jersey: Wiley-IEEE Press, 2006. [2] Bose B K. Modern power electronics and AC drives[M]. New York: Prentice Hall, 2002. [3] Sudhoff S D, Glover S F, Lamm P T, et al. Admittance space stability analysis of power electronic systems[J]. IEEE Transactions on Aerospace and Electronic Systems, 2000, 36(3): 965-973. [4] Jadric I, Boroyevich D, Jadric M. Modeling and control of a synchronous generator with an active DC load[J]. IEEE Transactions on Power Electronics, 2000, 15(2): 303-311. [5] Glover F S. Modeling and stability analysis of power electronics based systems[D]. Indiana: Purdue University, 2003. [6] Kundur P. Power system stability and control[M]. New York: McGraw-Hill, Inc., 1994. [7] 陈建业. 电力电子电路的计算机仿真[M]. 北京:清华大学出版社, 2003. [8] Zhu Huiyu, Burgos R P, Lacaux F, et al. Evaluation of average models for nine-phase diode rectifiers with improved AC and DC dynamics[C]. 21st IEEE Annual Conference on Applied Power Electronics Conference and Exposition, Dallas, TX, USA, 2006: 1324-1330. [9] Jatskevich J, Pekarek S D, Davoudi A. Parametric average-value model of synchronous machine- rectifier systems[J]. IEEE Transactions on Energy Conversion, 2006, 21(1): 9-18. [10] Sudhoff S D, Corzine K A, Hegner H J, et al. Transient and dynamic average-value modeling of synchronous machine fed load-commutated converters[J]. IEEE Transactions on Energy Conversion, 1996, 11(3): 508-514. [11] Han Liqiu, Wang Jiabin, David Howe. State-space average modeling of 6-and 12-pulse diode rectifiers[C]. The European Conference on Power Electronics and Applications, Aalborg, Denmark, 2007: 1-10. [12] Sanders S R, Verghese G C. Synthesis of averaged circuit models for switched power converters[J]. IEEE Transactions on Circuits and Systems, 1991, 38(8): 905-915. [13] Ma Weiming, Hu An, Liu Dezhi, et al. Stability of a synchronous generator with diode-bridge rectifier and back-EMF load[J]. IEEE Transactions on Energy Conversion, 2000, 15(4): 458-463. [14] 马伟明. 十二相同步发电机及其整流系统的研究[D]. 北京: 清华大学, 1995.