Abstract:This paper studies the effect that two terminal of the line trip in different time on the dynamic security region (DSR) by numerical simulation experiment in the case of three-phase short circuit. And come with three conclusions: When the two terminals of the line trip in different time, the hyperplane of the dynamic security region is approximately parallel; The range of the dynamic security region monotone decreasing with the increase of the trip time difference between the two ends of the line; There is an approximately linear relationship between the distance between the hyperplane of the dynamic security region and the trip time difference. The relationship between the transient stability limit and the time difference of the tripping time also satisfies the monotonicity and approximately linear. Based on the above empirical rules, a simplified algorithm for calculating the boundary of DSR is presented. The simulation results of the 10-generator, 39-bus New-England system verify the correctness of the above conclusions and methods.
刘怀东, 方伟, 王锦桥, 秦婷, 冯志强. 线路两端不同时跳闸对动态安全域的影响[J]. 电工技术学报, 2018, 33(13): 3034-3040.
Liu Huaidong, Fang Wei, Wang Jinqiao, Qin Ting, Feng Zhiqiang. The Influence of Different Trip Time on the Dynamic Security Region. Transactions of China Electrotechnical Society, 2018, 33(13): 3034-3040.
[1] 江知瀚, 刘蔚, 高旭, 等. 2015年冀北电网220kV及以上电压等级交流系统继电保护及安全自动装置设备及运行情况分析[J]. 华北电力技术, 2016(6): 51-55. Jiang Zhihan, Liu Wei, Gao Xu, et al. Equipment evaluation and operation analysis on protective relaying and stability control device of Jibei grid in 220 kV and above voltage AC systems in2015[J]. North China Electric Power, 2016(6): 51-55. [2] 郭振威, 姚建刚, 康童, 等. 一种输电线路超高速方向保护方法[J]. 电工技术学报, 2016, 31(22): 168-177. Guo Zhenwei, Yao Jiangang, Kang Tong, et al.A method for directional ultra-high-speed protection of transmission lines[J]. Transactions of China Electrotechnical Society, 2016, 31(22): 168-177. [3] 金立军, 董骁, 闫书佳, 等. 喷口结构对半自能式SF_6断路器最短燃弧时间的影响[J]. 高压电器, 2013(3): 64-68. Jin Lijun, Dong Xiao, Yan Shujia, et al.Impact of nozzle structure on short arc time of half-self-extinguish SF_6 circuit breaker[J]. High Voltage Apparatus, 2013(3): 64-68. [4] 罗干平. 126 kV SF6断路器分闸时间特性统计分析[J]. 高电压技术, 2001, 27(1): 67-68. Luo Ganping.Statistical analysis of opening time of 126 kV SF6 circuit breaker[J]. High Voltage Engineering, 2001, 27(1): 67-68. [5] 庞福滨, 杨毅, 袁宇波, 等. 智能变电站保护动作时间延时特性研究[J]. 电力系统保护与控制, 2016, 44(15): 86-92. Pang Fubin, Yang Yi, Yuan Yubo, et al.Research on characteristics of intelligent substation protection time delay[J]. Power System Protection and Control, 2016, 44(15): 86-92. [6] 刘宏君, 张兆云, 李辉. 光纤通道路径不一致对线路差动保护的影响[J]. 电力系统保护与控制, 2008, 36(12): 52-55. Liu Hongjun, Zhang Zhaoyun, Li Hui.Influence of the fibre route with difference on line differntial protection[J]. Power System Protection and Control, 2008, 36(12): 52-55. [7] 刘路辉, 庄劲武, 王晨, 等. 燃弧时间对混合型直流真空断路器分断特性的影响[J]. 电工技术学报, 2015, 30(24): 55-60. Liu Luhui, Zhuang Jinwu, Wang Chen, et al.Effect of arcing time upon the interruption characteristic of the hybrid DC vacuum circuit breaker[J]. Transactions of China Electrotechnical Society, 2015, 30(24): 55-60. [8] 余贻鑫. 电力系统安全域方法研究述评[J]. 天津大学学报, 2008, 41(6): 635-646. Yu Yixin.Review of study on methodology of security regions of power system[J]. Journal of Tianjin University, 2008, 41(6): 635-646. [9] 余贻鑫, 栾文鹏. 利用拟合技术决定实用电力系统动态安全域[J]. 中国电机工程学报, 1990, 10(增刊1): 22-28. Yu Yixin, Luan Wenpeng.Practical dynamic security regions of power systems[J]. Proceedings of the CSEE, 1990, 10(S1): 22-28. [10] 曾沅, 余贻鑫. 电力系统动态安全域的实用解法[J]. 中国电机工程学报, 2003, 23(5): 24-28. Zeng Yuan, Yu Yixin.A practical direct method for determining dynamic security regions of electric power systems[J]. Proceedings of the CSEE, 2003, 23(5): 24-28. [11] 秦超, 刘艳丽, 余贻鑫, 等. 含双馈风机电力系统的动态安全域[J]. 电工技术学报, 2015, 30(18): 157-163. Qin Chao, Liu Yanli, Yu Yixin, et al.Dynamic security region of power systems with double fed induction generator[J]. Transactions of China Electrotechnical Society, 2015, 30(18): 157-163. [12] 刘怀东, 唐晓玲, 高天亮, 等. 基于机组同调性的电力系统动态安全域改进解析法[J]. 电工技术学报, 2008, 23(4): 112-118. Liu Huaidong, Tang Xiaoling, Gao Tianliang, et al.An improved analytical method for determining dynamic security region of electrical power systems based on generator coherency[J]. Transactions of China Electrotechnical Society, 2008, 23(4): 112-118. [13] Liu Yanli, Yu Yixin.Probabilistic steady-state and dynamic security assessment of power transmission system[J]. Science China Technological Sciences, 2013, 56(5): 1198-1207. [14] 吴安平. 稳定计算中500 kV线路故障切除时间的确定[J]. 四川电力技术, 2008, 31(5): 7-8. Wu Anping.Determination of 500 kV line fault removal time in stability calculation[J]. Sichuan Electric Power Technology, 2008, 31(5): 7-8. [15] 殷自力, 陈宇星. 基于功率传输转移分布因子的简化电网潮流计算方法[J]. 电力系统保护与控制, 2016, 44(17): 25-30. Yin Zili, Chen Yuxing.A power flow computation method for reduction grid based on power transfer distribution factor[J]. Power System Protection and Control, 2016, 44(17): 25-30. [16] 苏慧玲, 李扬. 基于准稳态功率转移分布因子的电力系统复杂网络特性分析[J]. 电力自动化设备, 2013, 33(9): 47-53. Su Huiling, Li Yang.Analysis of complex network characteristics based on quasi-steady PTDF for power system[J]. Electric Power Automation Equipment, 2013, 33(9): 47-53.