The Inverse Problem Study of Plane Model Based on Magneto-Acoustic Tomography with Current Injection
Xia Hui1, Liu Guoqiang1, Huang Xin2, Guo Liang1,3
1. Institute of Electrical Engineering Chinese Academy of Sciences Beijing 100190 China;
2. Shandong Jiaotong University Jinan 250023 China;
3. Graduate University of Chinese Academy of Sciences Beijing 100190 China
Magneto-acoustic tomography with current injection (MAT-CI) is a new imaging technology combined with electrical impedance tomography and ultrasound imaging. It has the advantages of high contrast in electrical impedance tomography and high spatial resolution in ultrasound imaging. MAT-CI will have a broad application prospect in the field of bio-impedance imaging which is expected to obtain high quality images. In this paper, a new method for reconstructing the current density of the sample by the ultrasonic field signal is proposed. Firstly, using Wiener filtering deconvolution method, the original sound field p(r,t) is reconstructed by acoustic signals measured by the ultrasonic transducers. And then the sound source distribution ▽·(J×B0) is obtained by the time inversion method. Secondly, taken into account the only two components of the current density in the two-dimensional plane model, according to the current continuity theorem, the two components of the current density are reconstructed. Finally, the experimental platform with hardware system was established for MAT-CI. Using the biological tissue as the sample, the experiments were carried out. The conductivity image of the pork tissue was acquired. The reconstructed image shows that this method is feasible.
夏慧, 刘国强, 黄欣, 郭亮. 注入电流式磁声成像平面模型的逆问题研究[J]. 电工技术学报, 2017, 32(4): 147-153.
Xia Hui, Liu Guoqiang, Huang Xin, Guo Liang. The Inverse Problem Study of Plane Model Based on Magneto-Acoustic Tomography with Current Injection. Transactions of China Electrotechnical Society, 2017, 32(4): 147-153.
[1] Bagshaw A P, Liston A D, Bayford R H, et al. Electrical impedance tomography of human brain function using reconstruction algorithms based on the finite element method[J]. Neuroimage, 2003, 20(2): 752-764.
[2] Seagar A D, Barber D C, Brown B H. Thepretical limits to sensitivity and resolution in impedance imaging[J]. Clinical Physics and Physiological Measurement, 1987, 8(Supp.A): 13-31.
[3] Cherepenin V, Karpov A, Korjenevsky A, et al. A 3D electrical impedance tomography system for breast cancer detection[J]. Physiological Measurement. 2001, 22(1): 9-18.
[4] Seo J K, Pyo H C, Park C, et al. Image reconstruction of anisotropic conductivity tensor distribution in MREIT: computer simulation study[J]. Physics in Medicine and Biology, 2004, 49(5): 4371-4382.
[5] 付志红, 余慈拱, 侯兴哲, 等. 瞬变电磁法视电阻率成像的接地网断点诊断方法[J]. 电工技术学报, 2014, 29(9): 253-259. Fu Zhihong, Yu Cigong, Hou Xingzhe, et al. Transient electromagnetic apparent resistivity imaging for break point diagnosis of grounding grids[J]. Transactions of Electrotechnical Society, 2014, 29(9): 253-259.
[6] 刘瑞芳, 李俊峰, 桑秉谦, 等. 基于电磁场数值计算的变频供电感应电机耦合电容与轴电压的分析[J]. 电工技术学报, 2015, 30(14): 161-169. Liu Ruifang, Li Junfeng, Sang Bingqian, et al. Modeling of coupled capacitances and bearing voltage in induction motors fed by inverters based on numerical calculation of electromagnetic field[J]. Transactions of Electrotechnical Society, 2015, 30(14): 161-169.
[7] Kuchment P, Kunyansky L. Synthetic focusing in ultrasound modulated tomography[J]. Inverse Pro- blems and Imaging, 2010, 4(4): 665-673.
[8] Kuchment P. Mathematics of hybrid imaging: a brief review[J]. Mathematical Legacy of Leon Ehrenpreis, 2011, 1(16): 183-208.
[9] 陈民铀, 高兵, 杨帆, 等. 基于电-热-机械应力多物理场的IGBT焊料层健康状态研究[J]. 电工技术学报, 2015, 30(20): 252-260. Chen Minyou, Gao Bing, Yang Fan, et al. Healthy evaluation on IGBT solder based on electro-thermal- mechanical analysis[J]. Transactions of Electro- technical Society, 2015, 30(20): 252-260.
[10] Xu Y, He B. Magnetoacoustic tomography with magnetic induction (MAT-MI)[J]. Physics in Medi- cine and Biology, 2005, 50(21): 5175-5187.
[11] Li Y L, Ma Q Y, Zhang D, et al. Acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction[J]. Chinese Physics B, 2011, 20(8): 084302(1-3).
[12] Liu G Q, Huang X, Xia H, et al. Magnetoacoustic tomography with current injection[J]. Chinese Science Bulletin, 2013, 58(1): 3600-3606.
[13] 林颖, 郭志红, 陈玉峰. 基于卷积递归网络的电流互感器红外故障图像诊断[J]. 电力系统保护与控制, 2015, 43(16): 87-94. Lin Ying, Guo Zhihong, Chen Yufeng. Convolutional- recursive network based current transformer infrared fault image diagnosis[J]. Power System Protection and Control, 2015, 43(16): 87-94.
[14] Xu Y, Wang L V. Time resversal and its apllication to tomography with diffracting sources[J]. Physical Review Letters, 2004, 92(3): 033902(1-8).
[15] 刘国强. 医学电磁成像[M]. 北京: 科学出版社, 2006.