Abstract:Compared with 3p3l inverter, three phase legs of three-phase four-leg (3p4l) inverter could be decoupled by appropriate control, 3p4l inverter could also work with unbalanced load. 3p4l inverter can improve DC voltage utilization by injecting 3rd harmonic into fourth legs. In recent years, paralleled inverter technology is widely used in power electronic converter system to improve power level, and this technology can also be used in 3p4l inverter. But if current is out of control, circulating current will exist in four legs of paralleled 3p4l inverter, which could damages the inverter seriously exists in four legs. In 3p4l inverter controlled by method with 3rd harmonic injection, zero-sequence circulating current caused by unbalance parameters arises in four legs between parallel inverter modules. Based on novel 3rd harmonic average value injection method, this paper, therefore proposes control strategy for eliminating the circulating current in 3p4l inverter. Finally, simulation and experimental results verify the proposed method.
陈轶涵, 任磊, 邓翔, 龚春英. 一种基于3次谐波注入的并联三相四桥臂逆变器均流控制策略[J]. 电工技术学报, 2016, 31(4): 104-113.
Chen Yihan, Ren Lei, Deng Xiang, Gong Chunying. Current Sharing Control Method for Parallel Three Phase Four Leg Inverter Based on Third Harmonic Injection. Transactions of China Electrotechnical Society, 2016, 31(4): 104-113.
[1] 张方华, 龚春英. 高功率模块化航空静止变流器的研制[J]. 航空学报, 2009, 30(6): 1119-1125. Zhang Fanghua, Gong Chunying. High efficiency modular aeronautic static inverter[J]. ACTA Aero- nautica ET Astronautica Sinica, 2009, 30(6): 1119- 1125. [2] 葛红娟, 蒋华, 王培强. 基于内模原理的三相航空静止变流器闭环控制系统[J]. 电工技术学报, 2006, 21(9): 88-92. Ge Hongjuan, Jiang Hua, Wang Peiqiang. A novel three-phase aviation static inverter closed-loop control system based on the internal model principle[J]. Transactions of China Electrotechnical Society, 2006, 21(9): 88-92. [3] Vechiu I, Curea O, Camblong H. Transient operation of a four-leg inverter for autonomous applications with unbalanced load[J]. IEEE Transactions on Power Electronics, 2010, 25(2): 399-407. [4] Kim J H, Sul S K. A carrier-based PWM method for three-phase four-leg voltage source converters[J]. IEEE Transactions on Power Electronics, 2004, 19(1): 66-75. [5] 官二勇, 宋平岗, 叶满园. 基于3次谐波注入法的三相四桥臂逆变电源[J]. 电工技术学报, 2005, 20(12): 43-52. Guan Eryong, Song Pinggang, Ye Manyuan. Three- phase inverter with four bridge-legs based on three harmonic injection method[J]. Transactions of China Electrotechnical Society, 2005, 20(12): 43-52. [6] 闫耀民, 范瑜, 汪至中. 一种改进的电压电流混合控制的并联逆变器[J]. 铁道学报, 2003, 25(3): 55-58. Yan Yaomin, Fan Yu, Wang Zhizhong. Advanced voltage and current hybrid controlled parallel inver- ters[J]. Journal of the China Railway Society, 2003, 25(3): 55-58. [7] 肖岚, 胡文斌, 蒋渭忠, 等. 基于主从控制的逆变器并联系统研究[J]. 东南大学学报(自然科学版), 2002, 32(1): 133-137. Xiao Lan, Hu Wenbin, Jiang Weizhong, et al. Research on master-slave controlled inverter parallel system[J]. Journal of Southeast University (Natural Science Edition), 2002, 32(1): 133-137. [8] Tuladhar A, Jin H, Unger T, et al. Parallel operation of single phase inverters with no control inter- connections[C]//IEEE Applied Power Electronics Conference and Exposition (APEC), 1997, 1: 94-100. [9] Chiang S J, Chang J M. Parallel control of the UPS inverters with frequency dependent droop scheme[C]// IEEE 32nd Annual Power Electronics Specialists Conference, 2001, 2: 957-961. [10] 方天治, 阮新波, 肖岚, 等. 一种改进的分布式逆变器并联控制策略[J]. 中国电机工程学报, 2008, 28(33): 30-36. Fang Tianzhi, Ruan Xinbo, Xiao Lan, et al. An improved distributed control strategy of parallel inverters[J]. Proceedings of the CSEE, 2008, 28(33): 30-36. [11] Xu Zhuang, Li Rui, Zhu Hui, et al. Control of parallel multiple converters for direct-drive permanent- magnet wind power generation systems[J]. IEEE Trans- actions on Power Electronics, 2012, 27(3): 1259- 1269. [12] 孙驰, 鲁军勇, 马伟明. 一种新的三相四桥臂逆变器控制方法[J]. 电工技术学报, 2007, 22(2): 58-73. Sun Chi, Lu Junyong, Ma Weiming. A novel control method for three-phase four-leg inverter[J]. Trans- actions of China Electrotechnical Society, 2007, 22(2): 58-73. [13] 邓卫华, 张波, 丘东元, 等. 三相电压型PWM整流器转台反馈精确线性化解耦控制研究[J]. 中国电机工程学报, 2005, 25(7):97-103. Deng Weihua, Zhang Bo, Qiu Dongyuan, et al. The research of decoupled state variable feed back linearization control method of three-phase voltage- source PWM rectifier[J]. Proceedings of the CSEE, 2005, 25(7): 97-103. [14] Ge B, Peng F Z. Current balancer-based grid- connected parallel inverters for high power wind- power system[J]. International Transactions on Elect- rical Energy Systems, 2014, 24(1): 108-124. [15] Rouya H R N, Mokhtari H. Control of parallel three-phase inverters using optimal control and SVPWM technique[C]//IEEE International Sym- posium on Industrial Electronics, 2009: 1823-1828. [16] Lei He, Fei Lanling, Xiong Jian, et al. Research on paralleled three-phase four-leg voltage source inverters based on dual-loop control in αβo coor- dinate[C]//IEEE International Conference on Power Electronics and ECCE Asia, 2011: 2912-2919.