Abstract:The ride-through operation of photovoltaic(PV) generation under unbalanced grid voltage will produce apparent harmonic currents. This paper studied on power control of PV under unbalanced voltage, and analyzed the total harmonic distortion and the component of each harmonic of the inverter currents. Then the analytic formulas of power fluctuation, current total harmonic distortion and each current harmonic of the PV inverter were derived, and two algorithms of the adjustment coefficients of PV power control were proposed. The control strategy model of current harmonic suppression under unbalanced grid voltage was built. The feasibility of this method was verified by the simulation results produced by PSCAD/EMTDC.
周念成,楼晓轩,王强钢,王佳佳. 电网电压不平衡下三相光伏发电系统的谐波电流抑制[J]. 电工技术学报, 2015, 30(16): 245-253.
Zhou Niancheng,Lou Xiaoxuan,Wang Qianggang,Wang Jiajia. Harmonic Currents Suppression for Three-Phase Photovoltaic Power Generation System Under Unbalanced Grid Voltage Conditions. Transactions of China Electrotechnical Society, 2015, 30(16): 245-253.
[1] Guerrero J, Blaabjerg F, Zhelev T, et al. Distributed generation: toward a new energy paradigm[J]. IEEE Industrial Electronics Magazine, 2010, 4(1): 52-64. [2] Zhu Jizhong. Renewable Energy Applications in Power Systems[M]. New York: Nova Science Publishers, 2012. [3] 周念成, 邓浩, 王强钢, 等. 光伏与微型燃气轮机混合微网能量管理研究[J]. 电工技术学报, 2012, 27(1): 74-84. Zhou Niancheng, Deng Hao, Wang Qianggang, et al. Energy management strategy of PV and micro-turbine hybrid micro-grid[J]. Transactions of China Electrotech- nical Society, 2012, 27(1): 74-84. [4] 张犁, 孙凯, 吴田进, 等. 基于光伏发电的直流微电网能量变换与管理[J]. 电工技术学报, 2013, 28(2): 248-254. Zhang Li, Sun Kai, Wu Tianjin, et al. Energy conversion and management for DC microgrid based on photovoltaic generation[J]. Transactions of China Electrotechnical Society, 2013, 28(2): 248-254. [5] 周念成, 闫立伟, 王强钢. 光伏发电在微电网中接入及动态特性研究[J]. 电力系统保护与控制, 2010, 38(14): 119-127. Zhou Niancheng, Yan Liwei, Wang Qianggang. Research on dynamic characteristic and integration of photovoltaic generation in microgrids[J]. Power System Protection and Control, 2010, 38(14): 119-127. [6] 郭小强, 邬伟扬, 漆汉宏. 电网电压畸变不平衡情况下三相光伏并网逆变器控制策略[J]. 中国电机工程学报, 2013, 33(3): 22-28. Guo Xiaoqiang, Wu Weiyang, Qi Hanhong. Control strategies of three-phase PV grid-connected inverter under distorted and unbalanced voltage conditions[J]. Proceedings of the CSEE, 2013, 33(3): 22-28. [7] Castilla M, Miret J, Camacho A, et al. Reduction of current harmonic distortion in three-phase grid- connected photovoltaic inverters via resonant current control[J]. IEEE Transactions on Industrial Electronics, 2013, 60(4): 1464-1472. [8] 王强钢, 周念成, 颜伟, 等. 采用背靠背变流器接入配电网改善低压微网电压质量的控制设计[J]. 电工技术学报, 2013, 28(4): 171-181. Wang Qianggang, Zhou Niancheng, Yan Wei, et al. Control design for voltage quality improvement of low voltage microgrid using back-to-back converter connected to distribution network[J]. Transactions of China Electrotechnical Society, 2013, 28(4): 171-181. [9] Suh Y, Lipo T A. Control scheme in hybrid synchronous stationary frame for PWM AC-DC converter under generalized unbalanced operating conditions[J]. IEEE Transactions on Industry Applications, 2006, 42(3): 825-835. [10] 姚骏, 陈西寅, 廖勇, 等. 电网电压不平衡时永磁直驱风电机组的控制策略[J]. 电力系统保护与控制, 2011, 39(14): 99-106. Yao Jun, Chen Xiyin, Liao Yong, et al. Control strategy of a direct-driven permanent-magnet synchronous generator wind turbine under unbalanced grid voltage conditions[J]. Power System Protection and Control, 2011, 39(14): 99-106. [11] Rodriguez P, Timbus A V, Teodorescu R, et al. Flexible active power control of distributed power generation systems during grid faults[J]. IEEE Transac- tions on Industrial Electronics, 2007, 54(5): 2583- 2592. [12] Rodriguez P, Timbus A, Teodorescu R, et al. Reactive power control for improving wind turbine system behavior under grid faults[J]. IEEE Transactions on Power Electronics, 2009, 24(7): 1798-1801. [13] Wang Fei, Duarte J L, Hendrix M A M. Pliant active and reactive power control for grid-interactive con- verters under unbalanced voltage dips[J]. IEEE Transac- tions on Power Electronics, 2011, 26(5): 1511-1521. [14] Filho F, Tolbert L M, Cao Y, et al. Real-time selective harmonic minimization for multilevel inverters con- nected to solar panels using artificial neural network angle generation[J]. IEEE Transactions on Industry Applications, 2011, 47(5): 2117-2124. [15] Castilla M, Miret J, Sosa J L, et al. Grid-fault control scheme for three-phase photovoltaic inverters with adjustable power quality characteristics[J]. IEEE Transactions on Power Electronics, 2010, 25(12): 2930-2940. [16] Miret J, Castilla M, Camacho A, et al. Control scheme for photovoltaic three-phase inverters to minimize peak currents during unbalanced grid-voltage sags[J]. IEEE Transactions on Power Electronics, 2012, 27(10): 4262-4270. [17] 国家电网公司. Q/GDW 617—2011光伏电站接入电网技术规定[S]. 北京: 中国电力出版社, 2011. [18] 张明锐, 林承鑫, 徐瑞新. 一种基于固态变压器的光伏发电并网技术[J]. 电力系统保护与控制, 2012, 40(19): 133-138. Zhang Mingrui, Lin Chengxin, Xu Ruixin, et al. Grid- connected photovoltaic power generation technology based on SST[J]. Power System Protection and Control, 2012, 40(19): 133-138. [19] 郑必伟, 蔡逢煌, 王武. 一种单级光伏并网系统MPPT算法的分析[J]. 电工技术学报, 2011, 26(7): 90-96. Zheng Biwei, Cai Fenghuang, Wang Wu. Analysis and research of MPPT algorithm for a single-stage PV grid-connected power generation system[J]. Transac- tions of China Electrotechnical Society, 2011, 26(7): 90-96. [20] 刘邦银, 段善旭, 刘飞, 等. 基于改进扰动观察法的光伏阵列最大功率点跟踪[J]. 电工技术学报, 2009, 24(6): 91-94. Liu Bangyin, Duan Shanxu, Liu Fei, et al. Photo- voltaic array maximum power point tracking based on improved perturbation and observation method[J]. Transactions of China Electrotechnical Society, 2009, 24(6): 91-94.