Abstract:In the flexible VSC-HVDC, this paper proposed a control Strategy based on DD-PMSG seriesl topology offshore wind farm in grid voltage drop. During LVRT, generator side converter controls the DC bus voltage and take weak magnetic control when output voltage of generator is saturation.Grid side converter deliver reactive power to grid, maintain the total DC voltage stability.And coordinated control pitch angle of PMSGs, adjust speed of all PMSGs in series topologuy effectively.,make the wind farm store more wind energy in the security and stability. Achieve LVRT during grid voltage drop. The result of simulation proved that the scheme is running stable during grid voltage drop, can achieve good coordination control to speed of multi-generators, which could be used to the engineering practice.
黄晟,王辉,廖武,黄守道. 基于VSC-HVDC海上串联拓扑风电场低电压穿越控制策略研究[J]. 电工技术学报, 2015, 30(14): 362-369.
Huang Sheng,Wang Hui,Liao Wu,Huang Shoudao. Control Strategy Based on VSC-HVDC Series Topology Offshore wind Farm for Low Voltage Ride Through. Transactions of China Electrotechnical Society, 2015, 30(14): 362-369.
[1] 王志新, 吴杰, 徐烈, 王国强. 大型海上风电场并网VSC-HVDC变流器关键技术[J] 中国电机工程学报, 2013, 33(19): 14-26. Wang Zhixin, Wu Jie, Xu Lie, Wang Guoqiang. Key technologies of large offshore wind farm VSC-HVDC converters for grid integration[J]. Proceeding of the CSEE, 2013, 33(19): 14-26. [2] C. Du, E. Agneholm, and G. Olsson, VSC-HVDC system for industrial plants with onsite generator[J] IEEE Trans. Power Del. 2009, vol. 24, no. 3, pp. 1359-1366. [3] Anish Prasai, Jung-Sik Yim. A New Architecture for Offshore Wind Farms[J]. IEEE Transactions on Power Electronics, 2008, 23(3): 1198-1204. [4] AlanMullane, Gordon, Lightbody, R. yachamini. Wind-turbine fault ride through enhancemet[J]. IEEE Transactions on Power Systems. 2005, 20(4): 1929- 1933. [5] 林建新. 直驱永磁风电机组低电压穿越的一种控制策略[J]. 福建工程学院学报, 2011, 9(4): 312-375. Ling Jinxin. A Control Strategy of Low Vootage Ride through for permanent magent direct driven wind turbine[J] Juornal of Fujian University of techlology 2011, 9(4): 312-375. [6] 胡书举, 李建林, 许洪华. 直驱式VSCF风电系统直流侧Crowbar电路的仿真分析[J]. 电力系统及其自动化学报, 2008, 20(3): 118-123. Hu Shuju, Li Jianglin, Xu Honghua. Simulation Analysis of DC-link crowbar for direct-drive VSCF wind power system[J]. Proceeding of the CSU-EPSA. 2008, 20(3): 118-123. [7] 杨晓萍, 段先锋, 田录林. 直驱永磁同步风电系统低电压穿越的研究[J]. 西北农林科技大学学报, 2009, 37(8): 228- 123. Yang Xiaopin, Duan Xianfeng, Tian Luling. Research on Direct drive permanent synchronous wind power systems Low voltage ride through. Juornal of Northwest University. 2009, 37(8): 228- 123. [8] 孙君杨, 朱淼, 高强, 等. 大型海上交流风电场内部拓扑优化设计[J]. 电网技术, 电网技术, 2013, 37(7): 1978-1982. Sun Junyang, Zhu Miao, Gao Qiang, et al. Optimal design of internal topology for high power ac offshore wind farms[J]. Power System Technology, 2013, 37(7): 1978-1982. [9] Kun Zhao, Gengyin Li, Bozhong Wang, et al. Grid- connected topology of PMSG wind power system based on VSC-HVDC[J]. Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2011 4th International Conference on, 2011, 297- 302. [10] 肖磊. 直驱式永磁同步风力发电机在不平衡电网电压下的控制: [D] 长沙: 湖南大学, 2012. [11] S M Muyeen, Junji Tamura, Toshiaki Murata. 风电场并网稳定性技术[M], 北京: 机械工业出版社, 2011 [12] 任亚钊. 永磁直驱风力发电系统低电压穿越控制技术研究: [D]北京: 华北电力大学2012. [13] 李和明, 董淑惠, 王毅, 等. 永磁直驱风电机组低电压穿越时的有功和无功协调控制[J]. 电工技术学报, 2013, 28(5): 73-81. Li Heming, Dong Shuihui, Wang Yi Ren, et al. Coordinated control of active and reactive power of PMSG-based wind turbines for low voltage ride through[J] Transactions of China Electrotechnical Society, 2013, 28(5): 73-81. [14] Liang Chu, Feikun Zhou, Jianhua Guo, et al. Research of Flux-weakening Control Strategy for PMSM Used in Electric Vehicle Based on Stator Current Com- pensation[J]. 2011 International Conference on Trans- portation, Mechanical, and Electrical Engineering, 2011: 1601-1604. [15] J. M. Carrasco, L. G. Franquelo, J. T. Bialasiewicz, et al, Power-electronic systems for the grid integration of renewable energy sources: A survey. IEEE Transactions on Industrial Electronics. 2006, 53(4): 1002-1016.