Abstract:The safe operation of inverters is paid much attention recently. This paper presents a survey on existing diagnostic methods for open-switch faults in inverters. These methods are classified into two categories in terms of the measured variables: one is current-based method and the other is voltage-based method. Voltage and current modes under the open-switch fault modes in the inverters of the open-loop V/F controlled induction machine system and the vector controlled permanent magnet synchronous motor system are simulated and analyzed. The principles of each fault diagnosis method are introduced, and these methods are summarized and compared by applicability, complexity, detection time and reliability. And then difficulties and trends of the research on fault diagnosis of inverters are indicated.
安群涛, 孙力, 孙立志, 赵克. 三相逆变器开关管故障诊断方法研究进展[J]. 电工技术学报, 2011, 26(4): 135-144.
An Quntao, Sun Li, Sun Lizhi, Zhao Ke. Recent Developments of Fault Diagnosis Methods for Switches in Three-Phase Inverters. Transactions of China Electrotechnical Society, 2011, 26(4): 135-144.
[1] Rothenhagen K, Fuchs F W. Performance of diagnosis methods for IGBT open circuit faults in three phase voltage source inverters for AC variable speed dirves[C]. Proceedings of the 11th European Conference on Power Electronics and Applications, Dresden, Germany, 2005: 7-16. [2] Fuchs F W. Some diagnosis methods for voltage source inverters in variable speed drives with induction machines—a survey[C]. Proceedings of the IEEE Industrial Electronics Society Annual Conference, Roanoke, Virginia, USA, 2003: 1378- 1385. [3] Welchko B A, Lipo T A, Jahns T M, et al. Fault tolerant three-phase AC motor drive topologies: a comparison of features, cost, and limitations[J]. IEEE Transactions on Power Electronics, 2004, 19(4): 1108-1116. [4] 张兰红, 胡育文, 黄文新. 三相变频驱动系统中的逆变器的故障诊断与容错技术[J]. 电工技术学报, 2004, 19(12): 1-9. [5] Lu Bin, Santosh K S. A literature review of IGBT fault diagnostic and protection methods for power inverters[J]. IEEE Transactions on Industry Appli- cations, 2009, 45(5): 1770-1777. [6] Abrahamsen F, Blaabjerg F, Ries K, et al. Fuse protection of IGBTs against rupture[C]. Proceedings of the Nordic Workshop on Power and Industrial Electronics, Aalborg, Denmark, 2000: 64-68. [7] Iov F, Blaabjerg F, Ries K. IGBT fuses in voltage source converters[C]. Proceedings of the PCIM, Chicago, IL, USA, 2001: 267-276. [8] Karimi S, Gaillard A, Poure P, et al. FPGA-based real-time power converter failure diagnosis for wind energy conversion systems[J]. IEEE Transactions on Industrial Electronics, 2008, 55(12): 4299-4308. [9] Yu O K, Park N J, Hyun D S. A novel fault detection scheme for voltage fed PWM inverter[C]. Proceedings of the IEEE 32nd Annual Conference on Industrial Electronics, Paris, France, 2006: 2654-2659. [10] Peuget R, Courtine S, Rognon J P. Fault detection and isolation on a PWM inverter by knowledge-based model[J]. IEEE Transactions on Industry Applications, 1998, 34(6): 1318-1326. [11] Mendes A M S, Cardoso A J M. Voltage source inverter fault diagnosis in variable speed AC drives by the average current Park’s vector approach[C]. Proceedings of the IEEE International Electric Machines and Drives Conference, Madison, USA, 1999: 704-706. [12] Abramik S, Sleszynski W, Nieznanski J, et al. A diagnostic method for on-line fault detection and localization in VSI-fed AC drives[C]. Proceedings of the 10th European Conference on Power Electronics and Applications, Toulouse, France, CD-ROM. [13] Rothenhagen K, Fuchs F W. Performance of diagnosis methods for IGBT open circuit faults in voltage source active rectifiers[C]. Proceedings of the 35th Annual IEEE Power Electronics Specialists Conference, Aachen, Germany, 2004: 4348-4354. [14] Sleszynski W, Nieznanski J, Cichowski A. Open- transistor fault diagnostics in voltage-source inverters by analyzing the load currents[J]. IEEE Transactions on Industrial Electronics, 2009, 56(11): 4681-4688. [15] Gilreath P, Singh B N. A new centroid based fault detection method for 3-phase inverter-fed induction motors[C]. Proceedings of the IEEE Power Electronics Specialist Conference, Recife, Brazil, 2005: 2663-2669. [16] Diallo D, Benbouzid M E H, Hamad D, et al. Fault detection and diagnosis in an induction machine drive-a pattern recognition approach based on Concordia stator mean current vector[J]. IEEE Transactions on Energy Conversion, 2005, 20(3): 512-519. [17] Park J H, Kim D H, Kim S S, et al. C-ANFIS based fault diagnosis for voltage-fed PWM motor drive systems[C]. Proceedings of the IEEE Annual Meeting of the Fuzzy Information, Alberta, Canada, 2004: 379-383. [18] Zidani F, Diallo D, Benbouzid M E H, et al. A fuzzy-based approach for the diagnosis of fault modes in a voltage-fed PWM inverter induction motor drive[J]. IEEE Transactions on Industrial Electronics, 2008, 55(2): 586-593. [19] Guan Y F, Sun D, He Y K. Mean current vector based on line real-time fault diagnosis for voltage source inverter fed induction motor drives[C]. Proceedings of the IEEE International Electrical Machines and Drives Conference, Antalya, Turkey, 2007: 1114- 1118. [20] 孙丹, 孟濬, 管宇凡, 等. 基于相空间重构和模糊聚类的永磁同步电机直接转矩控制系统逆变器故障诊断[J]. 中国电机工程学报, 2007, 27(6): 49-53. [21] Kral C, Kafka K. Power electronics monitoring for a controlled voltage source inverter drive with induction machines[C]. Proceedings of the IEEE Power Electronics Specialist Conference, Galway, Ireland, 2000: 213-217. [22] Charfi F, Sellami F, Al Haddad K. Fault diagnostic in power system using wavelet transforms and neural networks[C]. Proceedings of the IEEE International Symposium on Industrial Electronics, Montreal, Quebec, Canada, 2006: 1143-1148. [23] Awadallah M A, Morcos M M. Diagnosis of switch open-circuit fault in PM brushless DC motor drives[C]. Proceedings of the Large Engineering Systems Conference on Power Engineering, Montreal, Quebec, Canada, 2003: 69-73. [24] Awadallah M A, Morcos M M. Automatic diagnosis and location of open-switch fault in brushless DC motor drives using wavelets and neuro-fuzzy systems[J]. IEEE Transactions on Energy Conversion, 2003, 21(1): 104-111. [25] Mamat M R, Rizon M, Khanniche M S. Fault detection of 3-phase VSI using wavelet-fuzzy algorithm[J]. American Journal of Applied Sciences, 2006, 3(1): 1642-1648. [26] Khanniche M S, Mamat M R. Wavelet-fuzzy-based algorithm for condition monitoring of voltage source inverter[J]. Electronics Letters, 2004, 40(4): 267-268. [27] 杨忠林, 吴正国, 李辉. 基于直流侧电流检测的逆变器开路故障诊断方法[J]. 中国电机工程学报, 2008, 28(27): 18-22. [28] Chang G W, Chen S K. An analytical approach for characterizing harmonic and interharmonic currents generated by VSI-fed adjustable speed drives[J]. IEEE Transactions on Power Delivery, 2005, 20(4): 2585-2593. [29] Ribeiro R L A, Jacobina C B, Silva E R C, et al. Fault detection of open-switch damage in voltage-fed PWM motor drive systems[J]. IEEE Transactions on Power Electronics, 2003, 18(2): 587-593. [30] Jacobina C B, Ribeiro R L A, Lima A M N, et al. Fault-tolerant reversible AC motor drive system[J]. IEEE Transactions on Industry Applications, 2003, 39(4): 1077-1084. [31] Brouji H E, Poure P, Saadate S. A fast reliable fault diagnosis method for fault tolerant shunt three-phase active filter[C]. Proceedings of the IEEE International Symposium on Industrial Electronics, Montreal, Quebec, Canada, 2006: 1688-1693. [32] Cruz S M A, Ferreira M, Cardoso A J M. Output error voltages - a first method to detect and locate faults in matrix converters[C]. Proceedings of the 34th Annual Conference of IEEE Industrial Electronics, Orlando, Florida, USA, 2009: 1319-1325. [33] Kwak S, Kim T. Fault detection and location of open-circuited switch faults in matrix converter drive systems[C]. Proceedings of the IEEE Vehicle Power and Propulsion Conference, Dearborn, MI, USA, 2009: 1476-1481. [34] 安群涛, 孙力, 赵克, 等. 基于开关函数模型的逆变器开路故障诊断方法[J]. 中国电机工程学报, 2010, 30(6): 1-6. [35] Rothenhagen K, Fuchs F W. Performance of diagnosis methods for IGBT open circuit faults in three phase voltage source inverters for ac variable speed drives[C]. Proceedings of the 11th European Conference on Power Electronics and Applications, Dresden, Germany, 2005: 1-10.