Analysis of Harmonic Disturbance Response of Multi-Inverter Grid-Connected System Combining Characteristic Root and Modal Analysis Method
Li Rong1, Li Jianwen1, Li Yonggang1, Sun Wei2
1. State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Baoding 071003 China; 2. Baoding Power Supply Subsidiary Company of State Grid Hebei Electric Power Supply Co. Ltd Baoding 071000 China
Abstract:The broadband oscillation caused by the interaction of a high proportion of new energy connected to the grid, grid impedance and load is a typical system stability problem. In recent years, some overvoltage phenomena have been difficult to classify into the classical stability problems. The electromagnetic transient process driving this phenomenon differs from the power-angle relationship on the rotor-side generator models using phase-locked loops (PLLs). To explain the dynamic behavior of inverter grid-connected systems disturbed by broadband harmonics, this paper derives a mathematical expression that characterizes the system's response to harmonic disturbances and analyzes the response's characteristics. Furthermore, the feasibility of analyzing harmonic responses using characteristic roots is verified by an example of a single inverter connected to the grid. The relationship between the characteristic root and the resonance mode is clarified for multi-inverter grid-connected systems. Finally, the dynamic behavior analysis is verified by simulation and experiments. The harmonic disturbance response expression is derived according to the characteristic roots and the harmonic disturbance. It is found that the system's response comprises two waveforms: the steady-state response and the transient response. The resonance characteristics of these two responses differ, with the magnitude of the resonance peak closely related to the damping coefficient ξ. A large peak occurs when ξ is close to 0, gradually decreasing as ξ increases, and no steady-state response resonance peak is observed when ξ>0.7. The characteristic root can effectively describe the harmonic disturbance response of inverter grid-connected systems. The dynamic behavior of the system after disturbance can be quantitatively analyzed by calculating the damping coefficient value. When multiple inverters are connected to the grid, the impedance-based system modeling method provides convenience for analyzing the stability of the inverter grid-connected system. The series and parallel resonance points in high-order networks are obtained by modal analysis. Accordingly, the characteristic roots of the system are obtained by converting the memory elements in the matrix from the frequency domain to the s domain, offering a simple and reusable approach to characterize coupling relationships within high-order networks and analyze system stability. The proposed method is verified using a single inverter connected to the grid and three inverters with different parameters to be connected to the grid. It is found that the parameter design of a single inverter can meet grid-connected harmonic requirements. However, when multiple inverters are connected to the grid, the damping coefficient of a single inverter decreases with the number of parallel inverters. A smaller damping coefficient makes the system less capable of actively suppressing harmonic oscillations. The slow attenuation of transient components results in a significantly increased waveform distortion rate over a short period of time. The following conclusions can be obtained through simulation and experiments: (1) As an analytical tool for finding system characteristic roots and traversing system resonance frequencies, the modal analysis method can provide numerical solutions and modal impedance curves simply and quickly. (2) The characteristic roots of the system can effectively describe the dynamic behavior of the system after disturbance. (3) A small damping coefficient renders the system susceptible to severe harmonic oscillations and deepens waveform distortion in a short period.
李戎, 李建文, 李永刚, 孙伟. 结合特征根及模态分析法的逆变器多机并网系统谐波扰动响应分析[J]. 电工技术学报, 2024, 39(14): 4519-4534.
Li Rong, Li Jianwen, Li Yonggang, Sun Wei. Analysis of Harmonic Disturbance Response of Multi-Inverter Grid-Connected System Combining Characteristic Root and Modal Analysis Method. Transactions of China Electrotechnical Society, 2024, 39(14): 4519-4534.
[1] 康重庆, 姚良忠. 高比例可再生能源电力系统的关键科学问题与理论研究框架[J]. 电力系统自动化, 2017, 41(9): 2-11. Kang Chongqing, Yao Liangzhong.Key scientific issues and theoretical research framework for power systems with high proportion of renewable energy[J]. Automation of Electric Power Systems, 2017, 41(9): 2-11. [2] 卓振宇, 张宁, 谢小荣, 等. 高比例可再生能源电力系统关键技术及发展挑战[J]. 电力系统自动化, 2021, 45(9): 171-191. Zhuo Zhenyu, Zhang Ning, Xie Xiaorong, et al.Key technologies and developing challenges of power system with high proportion of renewable energy[J]. Automation of Electric Power Systems, 2021, 45(9): 171-191. [3] 肖湘宁, 廖坤玉, 唐松浩, 等. 配电网电力电子化的发展和超高次谐波新问题[J]. 电工技术学报, 2018, 33(4): 707-720. Xiao Xiangning, Liao Kunyu, Tang Songhao, et al.Development of power-electronized distribution grids and the new supraharmonics issues[J]. Transactions of China Electrotechnical Society, 2018, 33(4): 707-720. [4] 谢小荣, 刘华坤, 贺静波, 等. 电力系统新型振荡问题浅析[J]. 中国电机工程学报, 2018, 38(10): 2821-2828, 3133. Xie Xiaorong, Liu Huakun, He Jingbo, et al.On new oscillation issues of power systems[J]. Proceedings of the CSEE, 2018, 38(10): 2821-2828, 3133. [5] 马宁宁, 谢小荣, 贺静波, 等. 高比例新能源和电力电子设备电力系统的宽频振荡研究综述[J]. 中国电机工程学报, 2020, 40(15): 4720-4732. Ma Ningning, Xie Xiaorong, He Jingbo, et al.Review of wide-band oscillation in renewable and power electronics highly integrated power systems[J]. Pro-ceedings of the CSEE, 2020, 40(15): 4720-4732. [6] 肖湘宁, 罗超, 廖坤玉. 新能源电力系统次同步振荡问题研究综述[J]. 电工技术学报, 2017, 32(6): 85-97. Xiao Xiangning, Luo Chao, Liao Kunyu.Review of the research on subsynchronous oscillation issues in electric power system with renewable energy sources[J]. Transactions of China Electrotechnical Society, 2017, 32(6): 85-97. [7] 胡寿松. 自动控制原理[M]. 7版. 北京: 科学出版社, 2019. [8] 谢小荣, 贺静波, 毛航银, 等. “双高”电力系统稳定性的新问题及分类探讨[J]. 中国电机工程学报, 2021, 41(2): 461-475. Xie Xiaorong, He Jingbo, Mao Hangyin, et al.New issues and classification of power system stability with high shares of renewables and power elec-tronics[J]. Proceedings of the CSEE, 2021, 41(2): 461-475. [9] Huang S H, Schmall J, Conto J, et al.Voltage control challenges on weak grids with high penetration of wind generation: ERCOT experience[C]//2012 IEEE Power and Energy Society General Meeting, San Diego, CA, USA, 2012: 1-7. [10] Zhang Yi, Zhu Songzhe, Sparks R, et al.Impacts of solar PV generators on power system stability and voltage performance[C]//2012 IEEE Power and Energy Society General Meeting, San Diego, CA, USA, 2012: 1-7. [11] 余墨多, 黄文焘, 邰能灵, 等. 基于光伏电站暂态特性的自适应暂稳控制方法[J]. 电工技术学报, 2020, 35(增刊2): 512-522. Yu Moduo, Huang Wentao, Tai Nengling, et al.Transient stability enhancement with an adaptive control scheme for photovoltaic plants[J]. Transa-ctions of China Electrotechnical Society, 2020, 35(S2): 512-522. [12] 李锡林, 查晓明, 田震, 等. 考虑频率突变影响的孤岛微电网系统建模和基于Lyapunov第二法的暂态稳定性分析[J]. 电工技术学报, 2023, 38(增刊1): 18-31. Li Xilin, Zha Xiaoming, Tian Zhen, et al.Modeling of island microgrid considering frequency mutation and transient stability analysis based on Lyapunov second method[J]. Transactions of China Electrotechnical Society, 2023, 38(S1): 18-31. [13] 梁贵书, 董华英. 电路理论基础[M]. 3版. 北京: 中国电力出版社, 2009. [14] 肖湘宁. 新一代电网中多源多变换复杂交直流系统的基础问题[J]. 电工技术学报, 2015, 30(15): 1-14. Xiao Xiangning.Basic problems of the new complex AC-DC power grid with multiple energy resources and multiple conversions[J]. Transactions of China Electrotechnical Society, 2015, 30(15): 1-14. [15] Wang Xiongfei, Blaabjerg F.Harmonic stability in power electronic-based power systems: concept, modeling, and analysis[J]. IEEE Transactions on Smart Grid, 2018, 10(3): 2858-2870. [16] Chen Zhiyong, Huang Xucheng, Luo An, et al.Wideband harmonic resonance characteristics and coordinated damping method for distributed gen-eration power plants[J]. IEEE Transactions on Industrial Electronics, 2019, 66(10): 7753-7764. [17] 李建文, 李戎, 吴滨源, 等. LCL型并网逆变器大小信号模型比较与分析[J]. 电机与控制学报, 2021, 25(5): 60-70. Li Jianwen, Li Rong, Wu Binyuan, et al.Comparison and analysis of large and small signal models of LCL grid-connected inverter[J]. Electric Machines and Control, 2021, 25(5): 60-70. [18] 吴滨源, 李建文, 李永刚, 等. 用于谐波劣化分析的并网逆变器阻抗灰箱拟合方法[J]. 电工技术学报, 2022, 37(4): 942-953. Wu Binyuan, Li Jianwen, Li Yonggang, et al.A gray-box fitting method of grid-connected inverters impedance for the analysis of harmonic degra-dation[J]. Transactions of China Electrotechnical Society, 2022, 37(4): 942-953. [19] 曾志杰, 肖华锋, 高博, 等. 结合阻抗比与振荡阻尼特征的并网系统谐波谐振稳定性分析方法[J]. 中国电机工程学报, 2020, 40(22): 7201-7212. Zeng Zhijie, Xiao Huafeng, Gao Bo, et al.Stability analysis method of harmonic resonance of grid-connected generation system based on impedance ratios and oscillation damping[J]. Proceedings of the CSEE, 2020, 40(22): 7201-7212. [20] 朱晓荣, 李铮, 孟凡奇. 基于不同网架结构的直流微电网稳定性分析[J]. 电工技术学报, 2021, 36(1): 166-178. Zhu Xiaorong, Li Zheng, Meng Fanqi.Stability analysis of DC microgrid based on different grid structures[J]. Transactions of China Electrotechnical Society, 2021, 36(1): 166-178. [21] 韩应生, 孙海顺, 秦世耀, 等. 电压源型双馈风电并网系统小扰动低频稳定性分析[J]. 电工技术学报, 2023, 38(5): 1312-1324, 1374. Han Yingsheng, Sun Haishun, Qin Shiyao, et al.Low-frequency stability analysis of voltage-sourced doubly-fed wind power grid-connected system under small disturbance[J]. Transactions of China Electro-technical Society, 2023, 38(5): 1312-1324, 1374. [22] He Jinwei, Li Yun wei, Bosnjak D, et al. Investigation and active damping of multiple resonances in a parallel-inverter-based microgrid[J]. IEEE Transa-ctions on Power Electronics, 2013, 28(1): 234-246. [23] 刘洋, 帅智康, 李杨, 等. 多逆变器并网系统谐波谐振模态分析[J]. 中国电机工程学报, 2017, 37(14): 4156-4164, 4295. Liu Yang, Shuai Zhikang, Li Yang, et al.Harmonic resonance modal analysis of multi-inverter grid-connected systems[J]. Proceedings of the CSEE, 2017, 37(14): 4156-4164, 4295. [24] 舒万韬, 洪芦诚, 刘宁波, 等. 多逆变器并网谐振特性分析[J]. 中国电机工程学报, 2018, 38(17): 5009-5019, 5298. Shu Wantao, Hong Lucheng, Liu Ningbo, et al.An analysis on resonance characteristics of multi-inverters grid-connected system[J]. Proceedings of the CSEE, 2018, 38(17): 5009-5019, 5298. [25] 李建文, 阮筱菲, 李永刚, 等. 弱电网下多LCL型并网逆变器谐振模态分析[J]. 太阳能学报, 2021, 42(2): 346-355. Li Jianwen, Ruan Xiaofei, Li Yonggang, et al.Resonance modal analysis for multiple LCL-type grid-connected inverters in weak grid[J]. Acta Energiae Solaris Sinica, 2021, 42(2): 346-355. [26] Harnefors L, Wang Xiongfei, Yepes A G, et al.Passivity-based stability assessment of grid-connected VSCs-an overview[J]. IEEE Journal of Emerging and Selected Topics in Power Electronics, 2016, 4(1): 116-125. [27] Riccobono A, Santi E.Comprehensive review of stability criteria for DC power distribution systems[J]. IEEE Transactions on Industry Applications, 2014, 50(5): 3525-3535. [28] 崔恒斌, 冯晓云, 林轩, 等. 车网耦合下高速铁路牵引网谐波谐振特性研究[J]. 电工技术学报, 2013, 28(9): 54-64. Cui Hengbin, Feng Xiaoyun, Lin Xuan, et al.Research on harmonic resonance characteristic of high-speed railway traction net considering coupling of trains and traction nets[J]. Transactions of China Electrotechnical Society, 2013, 28(9): 54-64. [29] Hong Lucheng, Shu Wantao, Wang Jianhua, et al.Harmonic resonance investigation of a multi-inverter grid-connected system using resonance modal analysis[J]. IEEE Transactions on Power Delivery, 2019, 34(1): 63-72. [30] 张占俊, 李建文, 董耀, 等. 弱电网下多逆变器并网谐振失稳分析方法[J]. 电气技术, 2020, 21(10): 21-28. Zhang Zhanjun, Li Jianwen, Dong Yao, et al.Method of resonance instability analysis of multiple grid-connected inverters in weak grid[J]. Electrical Engineering, 2020, 21(10): 21-28. [31] 仰彩霞, 刘开培, 李建奇, 等. 谐波谐振模态灵敏度分析[J]. 电工技术学报, 2011, 26(增刊1): 207-212. Yang Caixia, Liu Kaipei, Li Jianqi, et al.Modal sensitivity analysis for harmonic resonance[J]. Transactions of China Electrotechnical Society, 2011, 26(S1): 207-212. [32] 郭小颖, 唐俊杰, 舒铜, 等. 基于改进模态分析法的柔性多端交直流混联系统静态电压稳定性评估[J]. 电工技术学报, 2021, 36(17): 3741-3752. Guo Xiaoying, Tang Junjie, Shu Tong, et al.Static voltage stability assessment on hybrid alternating current/voltage source converter-multiple terminal direct current system using improved modal analysis[J]. Transactions of China Electrotechnical Society, 2021, 36(17): 3741-3752. [33] 王莹鑫, 徐永海, 陶顺, 等. 计及扰动源输出原副边特性的直流配电网谐振分析方法[J]. 电工技术学报, 2023, 38(7): 1723-1736. Wang Yingxin, Xu Yonghai, Tao Shun, et al.DC distribution system resonance characteristics analysis method considering the output characteristics of the perturbation source[J]. Transactions of China Electro-technical Society, 2023, 38(7): 1723-1736. [34] Sun Jian.Impedance-based stability criterion for grid-connected inverters[J]. IEEE Transactions on Power Electronics, 2011, 26(11): 3075-3078. [35] 陈新, 王赟程, 龚春英, 等. 采用阻抗分析方法的并网逆变器稳定性研究综述[J]. 中国电机工程学报, 2018, 38(7): 2082-2094, 2223. Chen Xin, Wang Yuncheng, Gong Chunying, et al.Overview of stability research for grid-connected inverters based on impedance analysis method[J]. Proceedings of the CSEE, 2018, 38(7): 2082-2094, 2223. [36] Varricchio S L, Gomes S, Martins N.Modal analysis of industrial system harmonics using the s-domain approach[J]. IEEE Transactions on Power Delivery, 2004, 19(3): 1232-1237. [37] Xu W, Huang Zhenyu, Cui Yu, et al.Harmonic resonance mode analysis[J]. IEEE Transactions on Power Delivery, 2005, 20(2): 1182-1190.