Common Mode Current Suppression for FB10 Three-Phase Non-isolated PV Grid-Connected Inverter |
Guo Xiaoqiang, Wei Baoze, Jia Xiaoyu, Lu Zhigang, Wang Baocheng, Sun Xiaofeng, Zhang Chunjiang |
Key Lab of Power Electronics for Energy Conservation and Motor Drive of Hebei Province Yanshan University Qinhuangdao 066004 China |
|
|
Abstract FB10 three-phase non-isolated PV grid-connected inverter is investigated in this paper. Based on the theoretical analysis, a new carrier-based modulation method is proposed to suppress the common mode current. Compared with the space vector modulation method, the proposed one has unique feature of significantly simplifying the switching logic generation procedure. The system common mode voltage and current characteristics are discussed. Aside from that, a new stationary PLL-less grid-connected control solution is presented and verified. Finally, a comparison with the conventional solution is carried out, and the results demonstrate that the proposed method can achieve the constant common mode voltage, which effectively suppresses the common mode current of FB10 grid-connected inverter.
|
Received: 06 December 2013
Published: 25 May 2015
|
|
|
|
|
[1] 邬伟扬, 郭小强, 无变压器非隔离型光伏并网逆变器漏电流抑制技术[J]. 中国电机工程学报, 2012, 32(18): 1-8. Wu Weiyang, Guo Xiaoqiang. A review of novel leakage current suppression techniques for trans- formerless photovoltaic inverters[J]. Proceedings of the CSEE, 2012, 32(18): 1-8. [2] Hernández J, Vidal P, Medina A. Characterization of the insulation and leakage currents of PV generators: Relevance for human safety[J]. Renewable Energy, 2010, 35(3): 593-601 [3] 张兴, 孙龙林, 许颇, 等, 单相非隔离型光伏并网系统中共模电流抑制的研究[J]. 太阳能学报, 2009, 30(9): 1203-1208. Zhang Xing, Sun Longlin, Xu Po, et al. Research on common-mode current reduction of nonisolated single-phase grid-connected photovoltaic systems[J]. Acta Energy Solars Sinica, 2009, 30(9): 1203-1208. [4] 肖华锋, 谢少军, 陈文明, 等. 非隔离型光伏并网逆变器漏电流分析模型[J]. 中国电机工程学报, 2010, 30(18): 9-13. Xiao Huafeng, Xie Shaojun, Chen Wenming, et al. Study on leakage current model for tansformerless photovoltaic grid-connected inverter[J]. Proceedings of the CSEE, 2010, 30(18): 9-13. [5] Xiao H, Xie S, Chen Y, et al. An optimized trans- formerless photovoltaic grid-connected inverter[J]. IEEE Transactions on Industrial Electronics, 2011, 58(5): 1887-1895. [6] 张犁, 孙凯, 冯兰兰, 等. 非隔离全桥并网逆变器并联运行系统[J]. 电工技术学报, 2012, 27(8): 21-27. Zhang Li, Sun Kai, Feng Lanlan, et al. Parallel opera- tion of non-isolated full bridge inverters in grid- connected system[J]. Transactions of China Electrotech- nical Society, 2012, 27(8): 21-27. [7] 马琳, 孙凯, Remus Teodorescu, 等. 高效率中点钳位型光伏逆变器拓扑比较[J]. 电工技术学报, 2011, 26(2): 108-114. Ma Lin, Sun Kai, Remus Teodorescu, et al. Comparison of the topologies of high efficiency neutral point clamping photovoltaic inverters[J]. Transactions of China Electrotechnical Society, 2011, 26(2): 108-114. [8] Yang B, Li W, Gu Y, et al. Improved transformerless inverter with common-mode leakage current elimina- tion for a photovoltaic grid-connected power system [J]. IEEE Transactions on Power Electronics, 2012, 27(2): 752-762. [9] Lopez O, Freijedo F D, Yepes A G, et al. Eliminating ground current in a transformerless photovoltaic applica- tion[J]. IEEE Transactions on Energy Conversion, 2010, 25(1): 140-147. [10] Cavalcanti M C, Oliveira K C, Farias A M, et al. Modulation techniques to eliminate leakage currents in transformerless three-phase photovoltaic systems[J]. IEEE Transactions on Industrial Electronics, 2010, 57(4): 1360-1368. [11] Rodriguez P, Munoz-Aguilar R, Vazquez G, et al. Constant common mode voltage modulation strategy for the FB10 power converter[C]. IEEE Energy Conver- sion Congress and Exposition, 2011, 1972-1977. [12] 郭小强, 邬伟扬, 赵清林, 等. 三相并网逆变器比例复数积分电流控制技术[J]. 中国电机工程学报, 2009, 29(15): 8-14. Guo Xiaoqiang, Wu Weiyang, Zhao Qinglin, et al. Current regulation for three-phase grid-connected inverters based on proportional complex integral control[J]. Proceedings of the CSEE, 2009, 29(15): 8-14. [13] Blaabjerg F, Teodorescu R, Liserre M, et al. Overview of control and grid synchronization for distributed power generation systems[J]. IEEE Transactions on Industrial Electronics, 2006, 53(5): 1398-1409. [14] 杨勇, 阮毅, 叶斌英. 基于锁相环和虚拟电网磁链的三相并网逆变器[J]. 电工技术学报, 2010, 25(4): 109-114. Yang Yong, Ruan Yi, Ye Binying. Three-phase grid- connected inverters based on PLL and virtual grid flux[J]. Transactions of China Electrotechnical Society, 2010, 25(4): 109-114 [15] Akagi H, Watanabe E H, Aredes M. Instantaneous power theory and applications to power conditioning [M]. Piscataway, NJ: IEEE Press, 2007. [16] Timbus A V, Rodriguez P, Teodorescu R, et al. Line impedance estimation using active and reactive power variations[C]. Proceedings of the IEEE Power Elec- tronics Specialists Conference, 2007: 1273-1279. [17] 郭小强, 邬伟扬. 电网电压畸变不平衡情况下三相光伏并网逆变器控制技术[J]. 中国电机工程学报, 2013, 33(3): 22-28. Guo Xiaoqiang, Wu Weiyang. Control of three-phase PV grid-connected inverter under distorted and unba- lanced voltage conditions[J]. Proceedings of the CSEE, 2013, 33(3): 22-28. |
|
|
|