Abstract:The three-phase grid-tied converters can be controlled either in the rotational reference frame or in the stationary reference frame. The grid synchronization signal needs to be extracted fast and accurately when either reference frame is employed. The sinusoidal amplitude integrator is employed to extract the grid synchronization signal in two-phase stationary reference frame for the control of three-phase grid-tied converters in the same reference frame in this paper. Through the vector description of three-phase voltage with harmonics and imbalance components, the grid synchronization method with multiple sinusoidal integrators is proposed. The presented method can eliminate the effects of harmonics and imbalance and extract the amplitude and phase information of the positive- sequence and negative-sequence components directly without the positive and negative sequence decomposition. The mathematical model is set up to show the mechanism of the presented synchronization method and determine the feedback parameter. A frequency adaptive method is designed to overcome the grid frequency variation. The theoretical and experimental results indicate that the presented synchronization method has the property of separate the positive-sequence and negative-sequence components for imbalance grid voltage with harmonics even under grid frequency variation condition.
杜雄,王国宁,孙鹏菊,周雒维. 两相静止坐标系下消除不对称和谐波影响的同步信号提取方法[J]. 电工技术学报, 2015, 30(4): 249-256.
Du Xiong,Wang Guoning,Sun Pengju,Zhou Luowei. Synchronization Signal Extraction Method in Two-Phase Stationary Reference Frame for Eliminating Imbalance and Harmonic Effects. Transactions of China Electrotechnical Society, 2015, 30(4): 249-256.
[1] 涂春鸣, 李慧, 唐杰, 等, 电网电压不对称对D-STATCOM 的影响分析及抑制[J]. 电工技术学报, 2009, 24(8): 114-121. Tu Chunming, Li Hui, Tang Jie, et al. Analysis and suppression of influence on D-STATCOM under unbalanced voltage of power system[J]. Transactions of China Electrotechnical Society, 2009, 24(8): 114-121. [2] Geng Hua, Yang Geng, Xu Dewei, et al. Unified power control for PMSG-based WECS operating under different grid conditions[J]. IEEE Transactions on Energy Conversion, 2011, 26(3): 822-830. [3] Li Shuhui, HaskewT A, Williams K A, et al. Control of DFIG wind turbine with direct-current vector control configuration[J]. IEEE Transactions on Sustainable Energy, 2012, 3(1): 1-11. [4] Moran L, Ziogas P D, Joos D. Design aspects of synchronous PWM rectifier-inverter systems under unbalanced input voltage conditions[J]. IEEE Transac- tions on Industry Applications, 1992, 28(6): 1286- 1293. [5] Song H S, Nam K. Dual current control scheme for PWM converter under unbalanced input voltage condi- tions[J]. IEEE Transactions on Industrial Electronics, 1999, 46(5): 953-959. [6] Zmood D N, Holmes D J. Stationary frame current regulation of PWM inverters with zero steady-state error[J]. IEEE Transaction Power Electronics, 2003, 18(3): 814-822. [7] Li Zixin, Li Yaohua, Wang Ping, et al. Control of three-phase Boost-type PWM rectifier in stationary frame under unbalanced input voltage[J]. IEEE Transac- tions Power Electronics, 2010, 25(10): 2521-2530. [8] Blaabjerg F, Teodorescuk R, Liserre M, et al. Overview of control and grid synchronization for distributed power generation systems[J]. IEEE Transactions on Industry Electronics, 2006, 53(5): 1398-1409. [9] Tsili M, Papathanassiou S. A review of grid code technical requirements for wind farms[J]. IET Rene- wable Power Generation, 2009, 3(3): 308-332. [10] Geng H, Xu D, Wu B. A novel hardware-based all- digital phase-locked loop applied to grid-connected power converters[J]. IEEE Transactions on Industry Electronics, 2011, 58(5): 1737-1745. [11] 张桂斌, 徐政, 王广柱. 基于空间矢量的基波正序、负序分量及谐波分量的实时检测方法[J]. 中国电机工程学报, 2001, 21(10): 1-5. Zhang Guibin, Xu Zheng, Wang Guangzhu. Study and simulation of real-time detecting method for funda- mental positive sequence, negative sequence components and harmonic components based on space vector[J]. Proceedings of the CSEE, 2001, 21(10): 1-5. [12] 袁旭峰, 程时杰, 文劲宇. 改进瞬时对称分量法及其在正负序电量检测中的应用[J]. 中国电机工程学报, 2008, 28(1): 52-58. Yuan Xufeng, Cheng Shijie, Wen Jinyu. An improved method of instantaneous symmetrical components and its detection for positive and negative sequence current [J]. Proceedings of the CSEE, 2008, 28(1): 52-58. [13] Souza H, Bradaschia F, Neves F, et al. A method for extracting the fundamental-frequency positive-sequence voltage vector based on simple mathematical trans- formations[J]. IEEE Transactions Power Electronics, 2009, 56(5): 1539-1547. [14] Kaur V, Blasco V. Operation of a phase locked loop system under distorted utility conditions[J]. IEEE Transactions on Industry Applications, 1997, 33(1): 58-63. [15] Guo X, Wu W, Chen Z. Multiple-complex coefficient- filter-based phase-locked loop and synchronization technique for three-phase grid-interfaced converters in distributed utility networks[J]. IEEE Transactions on Industry Electronics, 2011, 58(4): 1194-1204. [16] Yazdani D, Bakhshai A, Joos G, et al. A nonlinear adaptive synchronization technique for grid-connected distributed energy sources[J]. IEEE Transactions Power Electronics, 2008, 23(4): 2181-2186. [17] Routray A, Pradhan A K, Rao K P. A novel Kalman filter for frequency estimation of distorted signals in power systems[J]. IEEE Transactions on Instrumenta- tion and Measurement, 2002, 51(3): 469-479. [18] Rodr´ıguez P, Luna A, Mu˜noz-Aguilar R S, et al. A stationary reference frame grid synchronization system for three-phase grid-connected power converters under adverse grid conditions[J]. IEEE Transactions Power Electronics, 2012, 27(1): 99-112. [19] Rodriguez P, Pou J, Bergas J, et al. Decoupled double synchronous reference frame PLL for power converters control[J]. IEEE Transactions Power Electronics, 2007, 22(2): 584-592. [20] 李珊瑚, 杜雄, 王丽萍, 等, 解耦多同步参考坐标系电网电压同步信号检测方法[J]. 电工技术学报, 2011, 26(12): 183-189. Li Shanhu, Du Xiong, Wang Liping, et al. A grid voltage synchronizaiton method based on decoupled multiple synchronous reference frame[J]. Transactions of China Electrotechnical Society, 2011, 26(12): 183-189. [21] Yuan X, Merk W, Stemmler H, et al. Stationary frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions[J]. IEEE Transactions Power Electronics, 2002, 38(2): 523-532. [22] Martin K. Complex signal processing is not complex [J]. IEEE Transactions Circuits and System I: Regular Papers, 2004, 51(9): 1823-1836.