Abstract:Due to the problem that proportional-integral (PI) controller for current loop can not achieve zero-tracking-error in single-phase grid-connected inverter, and that performance of the controller may be affected when there is grid frequency shifting, a novel self-adaptive proportional resonant controller is proposed, which adjusts the resonant frequency point of resonant controller automatically based on a special filter through close-loop control so that grid-connected current can still achieve zero steady-state error when considering grid frequency shifting. Math analysis, simulations and physical experiments validate the validity of the proposed controller..
刘斌, 谢积锦, 李俊, 伍家驹. 基于自适应比例谐振的新型并网电流控制策略[J]. 电工技术学报, 2013, 28(9): 186-195.
Liu Bin, Xie Jijin, Li Jun, Wu Jiaju. Novel Grid-Connected Current Control Strategies Based on Self-Adaptive Proportional-Resonant. Transactions of China Electrotechnical Society, 2013, 28(9): 186-195.
[1] 王飞, 余世杰, 苏建徽, 等. 太阳能光伏并网发电系统的研究[J]. 电工技术学报, 2005, 20(5): 72-74. [2] 郭小强, 邬伟扬, 赵清林. 新型并网逆变器控制策略比较和数字实现[J]. 电工技术学报, 2007, 22(5): 111-116. [3] 顾和荣, 杨子龙, 邬伟扬. 并网逆变器输出电流滞环跟踪控制技术研究[J]. 中国电机工程学报, 2006, 26(9): 108-112. [4] 洪峰, 单任仲, 王慧贞, 等. 一种变环宽准恒频电流滞环控制方法[J]. 电工技术学报, 2009, 24(1): 115-119. [5] 涂春鸣, 罗安, 汤赐, 等. 注入式混合型有源电力滤波器的控制算法[J]. 中国电机工程学报, 2008, 28(24): 52-58. [6] Holmes D G, Lipo T. Pulse width modulation for power converters: principles and practice[M]. John Wiley and Sons, 2003. [7] 王久和, 罗安, 杨秀媛. 电网不平衡时电压型PWM整流器控制策略[J]. 中国电机工程学报, 2011, 31(18): 14-20. [8] Fukuda S, Yoda T. A novel current-tracking method for active filters based on a sinusoidal intemral mode[J]. IEEE Transactions on Industry Applications, 2001, 37(3): 888-895. [9] Yuan X, Merk W, Stemmler H, et al. Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions[J]. IEEE Transactions on Industry Applications, 2002, 38(2): 523-532. [10] Ciobotaru M, Teodorescu R, Blaabjerg F. A new single-phase PLL structure based on second order generalized integrator[C]. Power Electronics Specialists Conference, Denmark, 2006: 1-6. [11] 王颢雄, 马伟明. 双dq变换软件锁相环的数学模型 研究[J]. 电工技术学报, 2011, 26(7): 237-241. [12] Yepes A, Freijedo F, Doval-Gandoy J. Effects of discretization methods on the performance of resonant controllers[J]. IEEE Transactions on Power Electronics, 2010, 25(7): 1692-1712. [13] Rodriguez F, Bueno E, Aredes M. Discrete-time implementation of second order generalized integ- rators for grid converters[C]. 34th Annual Conference of IEEE Industrial Electronics, 2008: 176-181. [14] Rodriguez P, Luna A, Candela I, et al. Multiresonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions[J]. IEEE Transactions on Industrial Electronics, 2011, 58(1): 127-138. [15] Yazdani D, Bakhshai A, Jain P. A three-phase adaptive notch filter-based approach to harmonic/ reactive current extraction and harmonic decomposition[J]. IEEE Transactions on Power Electronics, 2010, 25(4): 914-923.