Abstract:The cascaded power electronics system is one of the most popular configurations in the real applications. In large scale or complex power supply systems, the stability for cascaded system including small-signal stability and large-signal stability is the key factor for reliable operation. This paper focuses on the large-signal stability of cascaded power electronic system under load transient, and clarifies the distinct difference from small-signal stability. Based on two cascaded voltage mode Buck converters, the small-signal stability and large-signal stability of the system are analyzed, and an analysis method for large-signal stability is proposed in this paper. With the proposed analysis method, the large-signal stability of cascaded system under load transient can be analyzed and designed. The simulation and experimental results verified the analysis method.
张阳, 张军明, 杜韦静. 负载动态下的级联系统大信号稳定性分析[J]. 电工技术学报, 2012, 27(10): 170-175.
Zhang Yang, Zhang Junming, Du Weijing. Large-Signal Stability of Cascaded System under Load Transient. Transactions of China Electrotechnical Society, 2012, 27(10): 170-175.
[1] Wang F, Cass C J, Boroyevich D, et al. Overview of research activities at center for power electronics systems[C]. Proceedings of IEEE Electric Ship Technologies Symposium Conference, 2005: 28-33. [2] Blaabjerg F, Consoli A, Ferreira J A , et al. The future of electronic power processing and conversion[J]. IEEE Transactions on Power Electronics, 2005, 20(30): 715-720. [3] Middlerook R D. Input filter considerations in design and application of switching regulators[C]. Conference Record of IEEE Institute for Advanced Studies Annual Meeting, 1976: 91-107. [4] Carl M Wildrick, Fred C Lee, Bo H Cho, et al. A method of defining the load impedance specification for a stable distributed power system[J]. IEEE Transactions on Power Electronics, 1995, 10(3): 280-285. [5] UsmanIftihar M, Bilal A. Analysis of input filter interactions in cascaded buck converters[C]. IEEE Internaional Conference on Industrial Technology, 2008: 1-6. [6] Rivetta C, Williamson G A. Large-signal analysis and control of buck converters loaded by DC-DC converters[C]. IEEE Power Electronics Specialists Conference, 2004: 3675-3680. [7] Rivetta C, Williamson G A. Large-signal analysis of a DC-DC buck power converter operating with constant power load[C]. IEEE Annual Conference of the Industrial Electronics Society, 2003, 1: 732-737. [8] 王建华, 张方华, 龚春英, 等. 带恒功率负载的DC-DC变换器起动过程分析[J]. 电工技术学报, 2009, 24(4): 122-125. Wang Jianhua, Zhang Fanghua, Gong Chunyin, et al. Start-up process analysis of DC-DC converter with constant power load[J]. Transations of China Elecrotechnical Society, 2009, 24(4): 122-125. [9] 王媛彬. 降压型开关变换器输入电压突变时的动态特性[C]. 中国电工技术学会电力电子学会第十届学术年会论文集, 2006. [10] 杜韦静, 张军明, 张阳, DC-DC变流器带恒功率负载动态响应分析及级联系统稳定性预测[J].电工技术学报, 2010, 26(增刊1): 83-90. Du Weijing, Zhang Junming, Zhang Yang, Transient load response analysis of DC-DC converter with constant power load and stability prognosis of cascaded system[J]. Transactions of China Electrotechnical Society, 2010, 26(Sub 1): 83-90.