Abstract:Research on interference caused by the outer magnetic field is very important for studying the electromagnetic compatibility of the electromagnetic relay. In the paper, 3D finite element method (FEM) is used to analyze the dynamic characteristics of electromagnetic relay interfered by power frequency field. The models of electromagnetic relay and outer power frequency magnetic field are founded. Through simulation and analysis, it is found out how the operation time, electromagnetic torque of electromagnetic relay, the pick-up velocity and the coil current changed with the outer interfered magnetic field. The relationship between the parameters of relay and magnetic field is quantitatively described. The experiment results agree well with the simulation, so the validity of the simulation is proved. The conclusion in this paper is of great value for research on the electromagnetic compatibility of electromagnetic relay.
杨文英, 任万滨, 翟国富, 李岐新. 工频磁场对电磁继电器动态特性影响的三维有限元分析[J]. 电工技术学报, 2011, 26(1): 51-56.
Yang Wenying, Ren Wanbin, Zhai Guofu, Li Qixin. 3-D Finite Element Analysis of Dynamic Characteristics of Electromagnetic Relay Interfered by Power Frequency Magnetic Field. Transactions of China Electrotechnical Society, 2011, 26(1): 51-56.
[1] Minegishi S. Frequency spectra of the arc current due to opening electric contacts in air[J]. IEEE Transactions on EMC, 1989, 31(4): 342-345. [2] Uchimura K, Fujita H, Ikesue S, et al. Noise induced by showering arc in switching relays and malfunction of digital circuits owing to its noise[C]. IEEE International Symposium on Electromagnetic Compatibility, Nagoya, Japan, 1989, 9: 400-405. [3] 李岐新, 刘青. 电磁继电器的电磁干扰现象及抑制方法[J]. 继电器, 1998, 26(1): 51-57. [4] 黄道春, 阮江军, 余世峰, 等. 特高压紧凑型输电线路工频电场强度计算[J]. 高电压技术, 2006, 32(7): 69-71. [5] 卢斌先, 王泽忠, 李成榕, 等. 500kV变电站开关操作瞬态电场测量与研究[J]. 中国电机工程学报, 2004, 24(4): 133-137. [6] Nils H, Dieter K. Overvoltages in secondary circuits of medium-voltage switchgear generated by multiple regnitions of circuit breakers [J]. IEEE Transactions on EMC, 1999, 41(4): 510-515. [7] Hosaka H, Kuwano H. Design and fabrication of miniature relay matrix and investigation of electromechanical interference in multi-actuator[R]. IEEE Workshop on Micro Electromechanical System, 1994: 313-318. [8] Kawase Y, Miyatani O, Yamaguchi T, et al. Numerical analysis of dynamic characteristics of electromagnets using 3-D finite-element method with edge elements[J]. IEEE Trans. Magn., 1994, 30: 3248-3251. [9] Yamaguchi T, Kawase Y, Shiomoto H, et al. 3-D finite-element analysis of dynamic characteristics of twin-type electromagnetic relay[J]. IEEE Trans. Magn., 2002, 38(2): 361-364. [10] Zhai G F, Yang W Y, Zhou X. 3-D finite element analysis of dynamic characteristics of twin-type relay interfered by uniform constant magnetic field[J]. IEICE Transactions on Electronics, 2008, 91(8): 1215-1221.