A Novel Wireless Parallel Control Strategy for Modular APF Based on the Point of Common Coupling Harmonic Currents Distribution |
Xu Sheng1, Cao Wu2, Zhao Jianfeng2 |
1. Taizhou Electric Power Conversion and Control Engineering Technology Research Center Taizhou university Taizhou 225300 China; 2. School of Electrical Engineering Southeast University Nanjing 210096 China |
|
|
Abstract A novel wireless parallel control strategy for modular active power filters (APF) is proposed in this paper based on the harmonic current distribution at the point of common coupling (PCC). This strategy is used to overcome the defects of traditional wired control methods, such as complex communication links and control, high cost and low reliability. Moreover, it can also solve unbalanced capacity distribution among modules under the capacity limitation wireless control mode. By utilizing the current distribution information at the PCC, the fault tolerant control can be realized without communication among the modules. First, the primary principle of this novel wireless control strategy was discussed in detail. The overall technological scheme was then introduced, including current detection, synchronous control, fault recognition, fault type recognition and automatic current-balancing control. Finally, the control system of the modular APF based on this strategy was designed. Theoretical analysis and experimental results show that, with this method, both the construction and the control system of the modules are independent with each other. In other word, the modular APF has higher flexibility, security and stability.
|
Received: 29 August 2015
Published: 30 June 2017
|
|
|
|
|
[1] Dang Pengpai, Ellinger T, Petzoldt J. Dynamic inter- action analysis of APF systems[J]. IEEE Transactions on Industrial Electronics, 2014, 61(9): 4467-4473. [2] Rahmani S, Hamadi A, Al-Haddad K, et al. A combination of shunt hybrid power filter and thyristor-controlled reactor for power quality[J]. IEEE Transactions on Industrial Electronics, 2014, 61(5): 2152-2164. [3] 张树全, 戴珂, 谢斌, 等. 并联型有源电力滤波器按容量比例分频段补偿并联控制策略[J]. 电工技术学报, 2010, 25(9): 115-121. Zhang Shuquan, Dai Ke, Xie Bin, et al. Parallel control of shunt active power filters with capacity proportion frequency allocation compensation[J]. Transactions of China Electrotechnical Society, 2010, 25(9): 115-121. [4] Rahmani S, Al-Haddad K, Fnaiech F. A three-phase shunt active power filter for damping of harmonic propagation in power distribution systems[C]//IEEE International Symposium on Industrial Electronics, Quebec, Canada, 2006, doi:10.1109/ISIE.2006. 295837. [5] Wang Yafang, Gu Juping, Chen Ruixiang, et al. The multi-modular shunt APF based on direct current control and frequency doubling carrier phase-shifted SPWM[C]//IEEE ECCE Asia Downunder (ECCE Asia), 2013: 867-871. [6] 徐长波, 鲁伟, 李春文. 大容量并联有源电力滤波器的模块化控制策略[J]. 电力系统自动化, 2013, 37(8): 117-122. Xu Changbo, Lu Wei, Li Chunwen. A control strategy for multi-modular shunt active power filters applied to high-power systems[J]. Automation of Electric Power System, 2013, 37(8): 117-122. [7] Ju Jianyong, Xu Dehong, Chen Min, et al. Control strategy of multi-modular active power filter system[C]// 22nd IEEE Annual Applied Power Electronics Conference, Anaheim, CA, USA, 2007: 686-691. [8] 汪玉凤, 张立, 褚占军. 载波调换调制技术在级联多电平SAPF中的应用[J]. 电力系统保护与控制, 2015, 43(6): 14-18. Wang Yufeng, Zhang Li, Chu Zhanjun. Application of carrier exchange modulation technique in multi- level cascaded SAPF[J]. Power System Protection and Control, 2015, 43(6): 14-18. [9] 刘国伟, 姜齐荣, 魏应冬. 低频率工况下模块化多电平变流器电容电压平衡控制策略[J]. 电工技术学报, 2014, 29(8): 166-172. Liu Guowei, Jiang Qirong, Wei Yingdong. Study on capacitor voltage balancing control of modular multi- level converters at low frequency[J]. Transactions of China Electrotechnical Society, 2014, 29(8): 166-172. [10] 平定钢, 孔洁, 陈国柱. 载波移相SPWM并联变流器及其环流问题的研究[J]. 电气自动化, 2008, 30(4): 17-19. Ping Dinggang, Kong Jie, Chen Guozhu. The research on carrier phase-shift SPWM and circulation currents in parallel converters[J]. Electrical Auto- mation, 2008, 30(4): 17-19. [11] 何英杰, 邹云屏, 刘飞, 等. 高压大容量有源电力滤波器并联运行研究[J]. 电工技术学报, 2007, 22(6): 94-100. He Yingjie, Zou Yunping, Liu Fei, et al. Research on output filter in hybrid active power filter[J]. Transactions of China Electrotechnical Society, 2007, 22(6): 94-100. [12] 吴翔宇, 沈沉, 赵敏, 等. 基于公共母线电压的微电网孤网运行下垂控制策略[J]. 电工技术学报, 2015, 30(24): 135-141. Wu Xiangyu, Shen Chen, Zhao Min, et al. A droop control method based on PCC bus voltage in islanded microgrid[J]. Transactions of China Electrotechnical Society, 2015, 30(24): 135-141. [13] 刘斌, 卢雄伟, 熊勇, 等. 负荷按容分配的无线并联逆变系统收敛性分析[J]. 电工技术学报, 2015, 30(21): 90-97. Liu Bin, Lu Xiongwei, Xiong Yong, et al. Conver- gence of the wireless parallel inverter system with volume-based load sharing[J]. Transactions of China Electrotechnical Society, 2015, 30(24): 135-141. [14] 杨振宇, 赵剑锋, 唐国庆. 并联型有源电力滤波器限流补偿策略研究[J]. 电力自动化设备, 2006, 26(3): 21-25. Yang Zhenyu, Zhao Jianfeng, Tang Guoqing. Research on current limiting compensation scheme of shunt APF[J]. Electric Power Automat ion Equipment, 2006, 26(3): 21-25. [15] 纪飞峰, 周荔丹, 姚钢, 等. 基于同步对称分量法的静止无功补偿装置[J]. 中国电机工程学报, 2005, 25(3): 24-29. Ji Feifeng, Zhou Lidan, Yao Gang, et al. Static var compensator based on the method of synchronous symmetrical component[J]. Proceedings of the CSEE, 2005, 25(6): 24-29. [16] 辛业春, 李国庆, 王尧, 等. 基于双dq坐标变换的三相电压锁相环的研究[J]. 电力系统保护与控制, 2014, 42(10): 114-118. Xin Yechun, Li Guoqing, Wang Yao, et al. Study of three-phase voltage phase locked loop based on double dq transformation synchronous reference frame[J]. Power System Protection and Control, 2014, 42(10): 114-118. [17] Zhang Yu, Duan Shanxu, Kang Yong, et al. The restrain of harmonic circulating currents between parallel inverters[C]//Power Electronics and Motion Control Conference, Xi’an, China, 2006: 1-5. |
|
|
|