Effect of Pole Number and Slot Number on Performance of Permanent Magnet Generator Directly Driven by Wind Turbine |
Zhang Yue1, 2, Wang Fengxiang1, Zhou Hao1, Zhang Guowei1 |
1. Shenyang University of Technology Shenyang 110178 China 2. Liaoning Institute of Science and Technology Benxi 117022 China |
|
|
Abstract The permanent magnet(PM) generator directly-driven by wind turbine has the advantages of high efficiency, simple structure and reliable operation. How to improve the performance and reduce the cost of the machine by proper choice of the pole number and stator slot number is an important problem to be solved for the design of a directly-driven PM wind generator. In the paper, the characteristics of a 1.5MW permanent magnet generator directly driven by wind turbine with low speed, large poles and big volume are analyzed based on circuit-field coupled finite element method. Under the same volume, the effect of stator's pole number and slot number on the performance of permanent magnet generator is compared and analyzed.
|
Received: 26 February 2008
Published: 14 February 2014
|
|
|
|
|
[1] 王承煦, 张源. 风力发电[M]. 北京:中国电力出版社, 2003. [2] 王凤翔, 张凤阁. 磁场调制式无刷双馈交流电机[M]. 长春:吉林大学出版社, 2004. [3] 王秀和, 等. 永磁电机[M]. 北京:中国电力出版社, 2007. [4] 谢若初. 直接驱动式永磁风力发电机设计研究[D]. 沈阳:沈阳工业大学, 2005. [5] 吴迪, 张建文. 变速直驱永磁风力发电机控制系统的研究[J]. 大电机技术, 2006(6):51-55. [6] 周晓燕, 史贺男, 王金平, 等. 低速永磁风力发电机起动阻力矩的分析计算[J]. 中小型电机, 2005, 32(2): 15-17. [7] 包金山. 三相分数槽永磁风力发电机的绕组排列[J].电机技术, 1996(2): 8-11. [8] Ki Chan Kim, Seung Bin Lim, et al. Analysis on the direct-driven high power permanent magnet generator for wind turbine[C]. The Eighth International Conference on Electrical Machines and Systems, Nanjing, China, 2005: 243-247. [9] 唐任远. 现代永磁电机理论与设计[M]. 北京:机械工业出版社, 1997. [10] Hideo Dohmeki, Yosihiro Shoji. Characteristic comparison of PMSM by slot/pole ratio[C]. The Eighth International Conference on Electrical Machines and Systems, Nanjing, China, 2005: 251-254. [11] Chen Jianyi, Chemmangot V Nayar, Xu Longya. Design and finite-element analysis of an outer-rotor permanent-magnet generator for directly coupled wind turbines[J]. IEEE Transactions on Magnetics, 2000, 36(5): 3802-3808. |
|
|
|