Transactions of China Electrotechnical Society  2021, Vol. 36 Issue (5): 1040-1051    DOI: 10.19595/j.cnki.1000-6753.tces.200768
Current Issue| Next Issue| Archive| Adv Search |
Power Deficit Calculation and under Frequency Load Shedding Strategy Based on the Frequency Deviation Area
Liu Ketian1, Zhang Jun2, Li Jun1, Chen Fan1
1. School of Electric Power Engineering Nanjing Institute of Technology Nanjing 211167 China;
2. Grid Development Comprehensive Research Institute State Grid Energy Research Institute Co. Ltd Beijing 102209 China

Download: PDF (1520 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Aiming at the power deficit calculation inaccuracy and the fixed amount of load shed by under frequency load shedding (UFLS), a power deficit calculation algorithm and an UFLS strategy based on frequency deviation area are proposed in this paper. The assumption that the frequency deviation areas of every bus are equal to the system center of inertia (COI) frequency deviation area at the same time is theoretically proved. Then, the relationship between the COI frequency deviation area and the system power deficit is derived. The UFLS can calculate the system power deficit only using the local frequency deviation area measured. The startup mechanism of the UFLS power deficit calculation program is designed and different UFLS schemes are proposed. Finally, the power deficit calculation algorithm and UFLS strategy are tested in the IEEE 39 and IEEE 145 bus system. The case studies show that the algorithm in this paper can calculate the power deficit accurately and the UFLS strategy can raise the minimum frequency of the system and accelerate the frequency recovery.
Key wordsPower deficit calculation      under frequency load shedding (UFLS) strategy      frequency deviation area      bus frequency      center of inertia (COI) frequency     
Received: 02 July 2020     
PACS: TM761  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Liu Ketian
Zhang Jun
Li Jun
Chen Fan
Cite this article:   
Liu Ketian,Zhang Jun,Li Jun等. Power Deficit Calculation and under Frequency Load Shedding Strategy Based on the Frequency Deviation Area[J]. Transactions of China Electrotechnical Society, 2021, 36(5): 1040-1051.
URL:  
https://dgjsxb.ces-transaction.com/EN/10.19595/j.cnki.1000-6753.tces.200768     OR     https://dgjsxb.ces-transaction.com/EN/Y2021/V36/I5/1040
Copyright © Transactions of China Electrotechnical Society
Supported by: Beijing Magtech