Accuracy Comparison of Digital Implementation on the Second-Order Generalized Integrator Frequency-Locked Loop
Yang Caiwei1, Wang Jian1, You Xiaojie1, Wang Chenchen1, Zhan Zhejun2
1. School of Electrical Engineering Beijing Jiaotong University Beijing 100044 China;
2. CRRC Yongji Electric Co. Ltd Yongji 044502 China

Download: PDF (74159 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  Second-order generalized integrator frequency-locked loop (SOGI-FLL) is a grid synchronization algorithm based on SOGI, which consists of adaptive filter (AF) and frequency-locked loop (FLL). SOGI is a widely used in current control and grid synchronization to achieve zero steady-state error when tracking sinusoidal signals, but its accuracy is affected by digital implementation. AF is a closed-loop structure of SOGI, and its accuracy is also affected by the digital implementation. Moreover, in AF digital implementation, the orthogonality of two output signals needs to be ensured to guarantee the phase stability of the grid. Discretization results are different when using different discretization methods. Common discretization methods are divided into two categories, i.e. numerical integration methods and non-integration methods. If using non-integration methods, the hierarchy of AF to be discretized can affect the discretization results as well. AF can be divided into three levels of integrator, SOGI and AF. Different discretization methods are used for the digital implementation of each hierarchy, which are compared by bode diagram, simulations and experiments. The comparisons of digital implementation focus on accuracy and orthogonality of output signals.
Key wordsGrid synchronization      second-order generalized integrator      frequency-locked loop      digital implementation      discretization     
Received: 28 June 2018      Published: 28 June 2019
PACS: TM461  
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Yang Caiwei
Wang Jian
You Xiaojie
Wang Chenchen
Zhan Zhejun
Cite this article:   
Yang Caiwei,Wang Jian,You Xiaojie等. Accuracy Comparison of Digital Implementation on the Second-Order Generalized Integrator Frequency-Locked Loop[J]. Transactions of China Electrotechnical Society, 2019, 34(12): 2584-2596.
URL:  
https://dgjsxb.ces-transaction.com/EN/10.19595/j.cnki.1000-6753.tces.L80212     OR     https://dgjsxb.ces-transaction.com/EN/Y2019/V34/I12/2584
Copyright © Transactions of China Electrotechnical Society
Supported by: Beijing Magtech