Fast Measurement Method of Voltage Unbalance Factor Based on Windowed FFT |
Wen He1, Jin Ran1, Meng Juan2, Li Fuhai1 |
1. College of Electrical and Information Engineering Hunan University Changsha 410082 China; 2. Department of Mechanical and Electrical Engineering Beijing Vocational College of Labor and Social Security Beijing 100029 China |
|
|
Abstract The voltage unbalance factor (VUF) is one of the most important parameters of power quality. The measurement of VUF depends on both the precise estimation of voltage phasors and the fast calculation of the magnitude of the zero, positive, and negative sequences. However, the accuracy of voltage phasors estimation is affected by the spectrum leakage and picket fence effect, and the measurement speed of VUF is limited because of the square root operation in the calculation of phase sequences. In this paper, a fast measurement method of voltage unbalance factor based on windowed interpolation fast Fourier transform (FFT) was presented. Firstly, windowed interpolation FFT was applied to calculate the voltage phasors. Then, the square root operation in the calculation of phase sequences was transformed into polynomial operation based on the geometric partitions. The simulation results show that the proposed method could achieve the same level of accuracy with the method recommended by GB/T 15543—2008. The measured results from the experiments of VUF verify the effective and practicability of the proposed method in further.
|
Received: 25 October 2016
Published: 30 August 2017
|
|
|
|
|
[1] 伞国成, 漆汉宏, 魏艳君, 等. 基于复功率的电网电压不平衡条件下并网逆变器控制策略[J]. 电工技术学报, 2017, 32(8): 229-236. San Guocheng, Qi Hanhong, Wei Yanjun, et al. Complex power based control strategy of grid- connected inverter under unbalanced grid voltage conditions[J]. Transactions of China Electrotechnical Society, 2017, 32(8): 229-236. [2] 周念成, 楼晓轩, 王强钢, 等. 电网电压不平衡下三相光伏发电系统的谐波电流抑制[J]. 电工技术学报, 2015, 30(16): 246-254. Zhou Niancheng, Lou Xiaoxuan, Wang Qianggang, et al. Harmonic currents suppression for three-phase photovoltaic power generation system under unbalanced grid voltage conditions[J]. Transactions of China Electrotechnical Society, 2015, 30(16): 246-254. [3] 岑扬, 黄萌, 査晓明. 电网电压不平衡跌落下同步参考坐标系锁相环瞬态响应分析[J]. 电工技术学报, 2016, 31(增刊2): 28-38. Cen Yang, Huang Meng, Zha Xiaoming. The transient response analysis of SRF-PLL under the unbalance grid voltage sag[J]. Transactions of China Electrotechnical Society, 2016, 31(S2): 28-38. [4] 屈克庆, 李文旗, 赵晋斌, 等. 孤岛微网不平衡负荷下控制策略[J]. 电力系统保护与控制, 2017, 45(11): 8-14. Qu Keqing, Li Wenqi, Zhao Jinbin, et al. Islanded microgrid control strategy under unbalanced loads[J]. Power System Protection and Control, 2017, 45(11): 8-14. [5] 林海雪. 现代电能质量的基本问题[J]. 电网技术, 2001, 25(10): 5-12. Lin Haixue. Main problems of modern power quality[J]. Power System Technology, 2001, 25(10): 5-12. [6] 张逸, 林焱, 吴丹岳. 电能质量监测系统研究现状及发展趋势[J]. 电力系统保护与控制, 2015, 43(2): 138-147. Zhang Yi, Lin Yan, Wu Danyue. Current status and development trend of power quality monitoring system[J]. Power System Protection and Control, 2015, 43(2): 138-147. [7] 朱鑫, 刘俊勇, 刘洋, 等. 基于滑模变结构的含不平衡负荷微电网控制策略研究[J]. 电力系统保护与控制, 2015, 43(6): 25-32. Zhu Xin, Liu Junyong, Liu Yang, et al. Study of micro-grid control strategy contained unbalanced load based on sliding-mode variable structure[J]. Power System Protection and Control, 2015, 43(6): 25-32. [8] GB/T 15543 电能质量三相电压不平衡[S]. 2008. [9] 罗蛟, 江亚群, 黄纯, 等. 基于DRSC窗递推DFT算法的电力谐波检测[J]. 电工技术学报, 2013, 28(9): 47-53. Luo Jiao, Jiang Yaqun, Huang Chun, et al. Power system harmonic parameters estimation based on recursive DFT algorithm with DRSC window[J]. Transactions of China Electrotechnical Society, 2013, 28(9): 47-53. [10] 庞浩, 李东霞, 俎云霄, 等. 应用FFT进行电力系统谐波分析的改进算法[J]. 中国电机工程学报, 2003, 23(6): 50-54. Pang Hao, Li Dongxia, Zu Yunxiao, et al. An improved algorithm for harmonic analysis of power system using FFT technique[J]. Proceedings of the CSEE, 2003, 23(6): 50-54. [11] 温和, 滕召胜, 黎福海, 等. 改进加窗频谱峰值拟合算法及谐波分析应用[J]. 电工技术学报, 2011, 26(10): 8-15. Wen He, Teng Zhaosheng, Li Fuhai, et al. Improved windowed spectral-peaks polynomial fitting algorithm and its application in power harmonic analysis[J]. Transactions of China Electrotechnical Society, 2011, 26(10): 8-15. [12] Wen He, Teng Zhaosheng, Wang Yong, et al. Simple interpolated FFT algorithm based on minimize sidelobe windows for power-harmonic analysis[J]. IEEE Transactions on Power Electronics, 2011, 26(9): 2570-2579. [13] Belega Daniel, Dominique Dallet. Frequency estimation via weighted multipoint interpolated DFT[J]. Science, Measurement & Technology, IET, 2008, 2(1): 1-8. [14] Duda Krzysztof. DFT interpolation algorithm for Kaiser-Bessel and Dolph-Chebyshev windows[J]. IEEE Transactions on Instrumentation and Measure- ment, 2011, 60(3): 784-790. [15] Wen He, Teng Zhaosheng, Wang Yong, et al. Spectral correction approach based on desirable sidelobe window for harmonic analysis of industrial power system[J]. IEEE Transactions on Industrial Electronics, 2013, 60(3): 1001-1010. [16] 潘文, 钱俞寿. 基于加窗插值FFT的电力谐波测量理论(Ⅱ)双插值FFT理论[J]. 电工技术学报, 1994, 9(2): 53-56. Pan Wen, Qian Yushou. Power harmonic measurement based on windows and interpolated FFT (Ⅱ) dual interpolated FFT algorithms[J]. Transactions of China Electrotechnical Society, 1994, 9(2): 53-56. [17] 温和, 滕召胜, 王永, 等. 改进加窗插值FFT动态谐波分析算法及应用[J]. 电工技术学报, 2013, 27(12): 270-277. Wen He, Teng Zhaosheng, Wang Yong, et al. Improved windowed interpolation FFT algorithm and application for power harmonic analysis[J]. Transa- ctions of China Electrotechnical Society, 2013, 27(12): 270-277. [18] 温和, 滕召胜, 卿柏元. Hanning自卷积窗及其在谐波分析中的应用[J]. 电工技术学报, 2009, 24(2): 164-169. Wen He, Teng Zhaosheng, Qing Baiyuan. Hanning self-convolution windows and its application to harmonic analysis Hanning[J]. Transactions of China Electrotechnical Society, 2009, 24(2): 164-169. [19] 温和, 滕召胜, 王一, 等. 基于三角自卷积窗的介损角高精度测量算法[J]. 电工技术学报, 2009, 24(3): 203-208, 215. Wen He, Teng Zhaosheng, Wang Yi, et al. High accuracy dielectric loss angle measurement algorithm based on triangular self-convolution window[J]. Transactions of China Electrotechnical Society, 2009, 24(3): 203-208, 215. [20] Nuttall Albert H. Some windows with very good sidelobe behavior[J]. IEEE Transactions on Acoustics, Speech and Signal Processing, 1981, 29(1): 84-91. |
|
|
|