Abstract:This paper proposes a novel control scheme of three-phase grid-connected inverters (GCIs), in which a proportional plus resonant (PR) regulator is adopted. The PR regulator, which is tuned at the synchronous angular frequency, can be applied in the stationary αβ reference frame directly. Furthermore, the PR regulator does not require any decomposition of positive- and negative-sequence currents. It will improve the performance of the grid-connected inverters during the transient process of the unbalanced grid voltage fault condition, and its fault ride through capability will be enhanced as well. Compared with the conventional PI control scheme and dual-PI control scheme, the correctness of the theoretical analysis and the feasibility of the unbalanced control scheme with the PR current regulator are validated by detailed experimental tests.
章玮, 王宏胜, 任远, 胡家兵, 贺益康. 不对称电网电压条件下三相并网型逆变器的控制[J]. 电工技术学报, 2010, 25(12): 103-110.
Zhang Wei, Wang Hongsheng, Ren Yuan, Hu Jiabing, He Yikang. Investigation on Control of Three-Phase Grid-Connected Inverters Under Unbalanced Grid Voltage Conditions. Transactions of China Electrotechnical Society, 2010, 25(12): 103-110.
[1] 胡家兵, 贺益康, 郭晓明, 等. 不平衡电网电压条件下双馈异步风力发电机系统的建模与控制[J]. 电力系统自动化, 2007, 31(14): 47-56. Hu Jiabing, He Yikang, Guo Xiaoming, et al. Modeling and control of the DFIG based wind- power generation system under unbalanced grid voltage conditions[J]. Automation of Electric Power Systems, 2007, 31(14): 47-56. [2] Song H S, Nam K. Dual current control scheme for PWM converter under unbalanced input voltage conditions[J]. IEEE Transactions on Industrial Electronics, 1999, 46(5): 953-959. [3] Clark Hochgraf, Lasseter R H. Statcom controls for operation with unbalanced voltages[J]. IEEE Transactions on Power Delivery, 1998, 13(2): 538-544. [4] Sun T, et al. Transient analysis of grid-connected wind turbines with DFIG after an external short- cincuit fault[C]. Proceeding of NWPC, Sweden, 2004. [5] Sato Y, Ishizuka T, Nezu K, et al. A new control strategy for voltage-type PWM rectifier to realize zero steady-state control error in input current[J]. IEEE Transactions on Industry Application, 1998, 34(3): 480-486. [6] Teodorescu R, et al. Proportional-resonant controllers and filters for grid-connected voltage-source converters[J]. IEE Proceedings of Electric Power Application, 2006, 153(5): 750-762. [7] Hu Jiabing, He Yikang, Wang Hongsheng. Adaptive rotor current control for wind-turbine driven DFIG using resonant controllers in a rotor rotating reference frame[J]. J. Zhejiang Univ. Sci. A, 2008, 9(2): 149-155. [8] Hu Jiabing, He Yikang, Nian Heng. Enhanced control of DFIG-used back-to-back PWM VSC under unbalanced grid voltage conditions[J]. J. Zhejiang Univ. Sci. A, 2007, 8(8): 1330-1339. [9] National Grid Transco. Appendix1, Extracts from the Grid Code-Connection Conditions. www.nationalgrid.com, Feb. 2004. [10] 郭锁凤. 计算机控制系统设计与实现[M]. 北京: 航天工业出版社, 1987.