电工技术学报  2022, Vol. 37 Issue (7): 1679-1688    DOI: 10.19595/j.cnki.1000-6753.tces.201643
“高效节能及智能化电机系统”专题 |
不同定子绕组结构五相感应电机开路故障时性能对比分析
范舒婷, 孟大伟, 艾萌萌
哈尔滨理工大学电气与电子工程学院 哈尔滨 150080
Comparison and Analysis of the Performance of Five-Phase Induction Motors with Different Stator Winding Connections under Open-Circuit Conditions
Fan Shuting, Meng Dawei, Ai Mengmeng
School of Electrical and Electronic Engineering Harbin University of Science and Technology Harbin 150080 China
全文: PDF (15219 KB)   HTML
输出: BibTeX | EndNote (RIS)      
摘要 为研究不同绕组结构对五相电机的影响,在现行单绕组及星形-五边形组合绕组的基础上,该文提出三种新型组合绕组:五边形-星形绕组、五角星-星形绕组与星形-五角星绕组。首先,建立绕组磁动势模型与电压不平衡系数(VUF)计算模型,利用有限元方法计算电机绕组磁动势(MMF)谐波含量、电压不平衡系数。其次,制作15kW五相感应电机,并以此为样机对不同绕组结构五相感应电机开路故障下的稳态性能进行分析。仿真及实验结果表明,对于单绕组结构,开路状态下五边形绕组最有利于电机运行;而对于组合式绕组,该文提出的五边形-星形绕组相比于现行的星形-五边形绕组,既有磁动势谐波含量低的优点,又可以进一步减小电压不平衡系数,提高可带负载转矩,更有利于电机在开路情况下运行。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
范舒婷
孟大伟
艾萌萌
关键词 五相电机组合绕组开路故障最大转矩倍数电压不平衡系数    
Abstract:Based on the existing single winding and star-pentagon combined winding, this paper proposed three new types of combined windings: pentagon-star winding, pentacal-star winding, and star-pentacal winding, to study the effects of different winding connections on five-phase motors. First, the winding magnetomotive force (MMF) model and the voltage unbalance ratio measurement model were developed. The harmonic content of the motor winding MMF and the voltage unbalance ratio were calculated using the finite element method. Secondly, a 15kW five-phase induction motor was designed. Using this as a prototype, the steady-state output of a five-phase induction motor with various winding connections was investigated under open-circuit faults. According to the simulation and experimental results, the pentagon winding is most beneficial to the motor's operation for the single winding connection under open-circuit faults. Comparing with the existing star-pentagon winding for the combined winding, the pentagon-star winding introduced in this paper not only has a low MMF harmonic content, but can reduce the voltage unbalance ratio and increase the maximum load torque, which is beneficial to the motor running under open-circuit.
Key wordsFive-phase motor    combined winding    open-circuit fault    max torque ratio    voltage unbalanced factor (VUF)   
收稿日期: 2020-12-15     
PACS: TM343  
基金资助:国家自然科学基金(52077047)和黑龙江省自然基金(LH2020E092)资助项目
通讯作者: 孟大伟 男,1956年生,教授,博士生导师,研究方向为特种电机CAD及优化设计的理论与应用。E-mail: mengdawei@hrbust.edu.cn   
作者简介: 范舒婷 女,1995年生,博士研究生,研究方向为特种电机的设计及其物理场分析。E-mail: 804296248@qq.com
引用本文:   
范舒婷, 孟大伟, 艾萌萌. 不同定子绕组结构五相感应电机开路故障时性能对比分析[J]. 电工技术学报, 2022, 37(7): 1679-1688. Fan Shuting, Meng Dawei, Ai Mengmeng. Comparison and Analysis of the Performance of Five-Phase Induction Motors with Different Stator Winding Connections under Open-Circuit Conditions. Transactions of China Electrotechnical Society, 2022, 37(7): 1679-1688.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/10.19595/j.cnki.1000-6753.tces.201643          https://dgjsxb.ces-transaction.com/CN/Y2022/V37/I7/1679