电工技术学报  2019, Vol. 34 Issue (24): 5244-5251    DOI: 10.19595/j.cnki.1000-6753.tces.181672
高电压与绝缘 |
获取XLPE绝缘直流电压耐受指数的步进应力试验参数选取方法研究
杨丽君1, 李仲轩1, 姚人允2, 边浩然1, 袁媛1
1. 输配电装备及系统安全与新技术国家重点实验室(重庆大学) 重庆 400044;
2. 国网重庆市电力公司南岸供电分公司 重庆 401336
Selection of Step-Stress Test Parameters for Obtaining DC Voltage Endurance Coefficient of XLPE Insulation
Yang Lijun1, Li Zhongxuan1, Yao Renyun2, Bian Haoran1, Yuan Yuan1
1. State Key Laboratory of Transmission & Distribution Equipment and Power System Safety and New Technology Chongqing University Chongqing 400044 China;
2. State Grid Chongqing Nan’an Power Supply Company Chongqing 401336 China;
全文: PDF (17597 KB)  
输出: BibTeX | EndNote (RIS)      
摘要 交联聚乙烯(XLPE)绝缘的直流电压耐受指数n是材料的重要性能参数,也是直流电缆绝缘厚度设计及出厂试验电压参数选取的重要依据。步进应力法作为一种高效的电寿命试验方法,其试验参数的选取对耐受指数n值的结果影响较大。该文提出一种步进应力试验的参数选取方法,该方法以累积损伤-时间(D-t)曲线、损伤矩阵D方差与n值关系曲线S(n)及S(n)曲线的二阶导数d2S(n)/dn2三个指标作为试验参数选取的依据。该方法为绝缘材料的步进应力和恒定应力电寿命试验结果的等效性评价提供了理论支撑。试验数据表明,通过该方法筛选的步进应力试验参数获得的电压耐受指数n值(n=12.0)与恒定应力下的结果(n=12.2)具有较好的一致性。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
杨丽君
李仲轩
姚人允
边浩然
袁媛
关键词 恒定应力试验步进应力试验电压耐受指数XLPE绝缘累积损伤高压直流电缆    
Abstract:The voltage endurance coefficient is an important performance parameter of XLPE insulation, and is also of vital basis in cable design and selection of delivery test voltage. As a high-efficiency electrical life test method, parameter selection of the step-stress method has a great influence on the test results of the voltage endurance coefficient n. In this paper, a parameter selection method for step-stress test was proposed based on three indicators, i.e. cumulative damage-time (D-t) curve, variance of damage matrix D and n value relationship curve S(n), and second order of S(n) curve. These three indicators were used as the basis for the selection of the test parameters. This method provides theoretical support for the equivalence evaluation of the step-stress method and constant-stress method in electrical life test results of insulating materials. The experimental data show that the value of voltage endurance coefficient n (n=12.0) obtained by the step-stress test parameters screened by this method has good equivalence with the result under constant-stress method (n=12.2).
Key wordsStep-stress test    constant stress test    voltage endurance coefficient    XLPE insulation    cumulative damage    DC power cable   
收稿日期: 2018-10-23      出版日期: 2019-12-30
PACS: TM215.1  
通讯作者: 杨丽君, 女,1980年生,教授,博士生导师,研究方向为高压设备绝缘状态和故障诊断的在线监测,以及电力变压器和电缆的老化机理和诊断。E-mail:yljcqu@cqu.edu.cn   
作者简介: 李仲轩,男,1995年生,硕士研究生,研究方向为XLPE的加速老化试验和老化机理。E-mail:li327@uwm.edu
引用本文:   
杨丽君, 李仲轩, 姚人允, 边浩然, 袁媛. 获取XLPE绝缘直流电压耐受指数的步进应力试验参数选取方法研究[J]. 电工技术学报, 2019, 34(24): 5244-5251. Yang Lijun, Li Zhongxuan, Yao Renyun, Bian Haoran, Yuan Yuan. Selection of Step-Stress Test Parameters for Obtaining DC Voltage Endurance Coefficient of XLPE Insulation. Transactions of China Electrotechnical Society, 2019, 34(24): 5244-5251.
链接本文:  
https://dgjsxb.ces-transaction.com/CN/10.19595/j.cnki.1000-6753.tces.181672          https://dgjsxb.ces-transaction.com/CN/Y2019/V34/I24/5244