Abstract:There is larger effect of single-phase reclosure sequence on ultra-high voltage AC/DC parallel system's transient stability. To discuss the inherent mechanism of this issue, single generator-ultra-high voltage AC/DC parallel transmission-infinite bus system is constructed, and equivalent AC impedance of DC system is derived based on switch function method and thus electromagnetic power expression is obtained. By analyzing the changing characteristic of power angle during the whole process that single-phase permanent fault is occurred, single-phase breaker is tripped, reclose to permanent fault and three phase breaker is tripped, influence of single-phase reclosure sequence on system's transient angle stability is described. Setting criterion of reclosure sequence to decrease acceleration area and enhance system's transient stability is proposed, i.e. to reclose on the terminal with smaller equivalent impedance of system. Correctness and effectiveness of the criterion is simulated in single generator-ultra-high voltage AC/DC parallel transmission-infinite bus system and south China power grid in 2010.
孙士云, 束洪春, 于继来. 单相重合时序对特高压交直流并联系统暂稳影响的机理分析[J]. 电工技术学报, 2009, 24(10): 106-113.
Sun Shiyun, Shu Hongchun, Yu Jilai. Mechanism Analysis of Single-Phase Reclosure Sequence's Influence on Ultra-High Voltage AC/DC Parallel System. Transactions of China Electrotechnical Society, 2009, 24(10): 106-113.
[1] 贺家李, 宋从矩. 电力系统继电保护原理[M]. 北京:中国电力出版社, 1994. [2] 盛鹍. 750kV输电线保护及重合闸动作与过电压的抑制[D]. 天津: 天津大学, 2004. [3] 袁宇春, 张保会. 基于EEAC 的重合闸最佳时刻的计算[J]. 电力系统自动化, 1999, 23(17): 10-12. [4] 张保会, 尹项根. 电力系统继电保护[M]. 北京: 中国电力出版社, 2005. [5] 袁宇春, 张保会, 钱国明. 多机电力系统中重合闸最佳时刻的研究[J]. 电力系统自动化, 1998, 22(4): 16-18. [6] 李斌, 李永丽, 贺家李, 等. 750kV输电线路保护与单相重合闸动作的研究[J]. 电力系统自动化, 2004, 28(13): 73-76. [7] 袁越, 葛耀中, 张保会. 自适应分相重合闸对机组轴系扭振和系统暂态稳定影响的研究[J]. 电力系统自动化1997, 21(5): 19-22. [8] 张保会, 康小宁, 薄志谦. 发电厂送出线重合闸时机的优选与捕捉[J]. 中国电机工程学报, 1995, 15(3): 173-178. [9] 束洪春, 董俊, 孙士云, 等. 重合闸时序对交直流混联输电系统暂态稳定裕度的影响[J]. 电力系统自动化, 2006, 30(19): 73-76. [10] Shu Hongchun, Sun Shiyun, Dong Jun, et al. Research of transient stability margin affected by single-phase reclosing sequence in southern China power grid[C]. The 7th International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006), Hongkong, China, 2006: 269-273. [11] Shu Hongchun, Sun Shiyun, Dong Jun, et al. Research of transient stability margin affected by single-phase reclosing[C]. IEEE Power System Technology International Conference, Chongqing, China, 2006: 1764-1767 [12] 束洪春, 孙士云, 董俊, 等. 单相重合时序对系统暂态稳定的影响研究[J]. 电力系统自动化设备, 2007, 27(3): 1-4 Shu Hongchun, Sun Shiyun, Dong Jun, et al. Influence of single-phase reclose sequence on system transient stability[J]. Electric Power Automation Equipment, 2007, 27(3): 1-4. [13] Sun Shiyun, Shu Hongchun, Zhang Guangbin, et al. Study of autoreclosure strategy for 110kV overhead-underground parallel lines in Kunming power grid[C]. The Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT 2008), Nanjing, 2008: 1259-1264. [14] 马玉龙. 高压直流输电系统的稳定性分析[D]. 北京:华北电力大学, 2006. [15] 浙江大学发电教研组直流输电科研组. 直流输电[M]. 北京: 水利电力出版社, 1985. [16] 薛禹胜, 徐泰山, 刘兵, 等. 暂态电压稳定性及电压跌落可接受性[J]. 电力系统自动化, 1999, 23(14): 4-8.